Background: Enterococcus faecalis is emerging as an important endodontic pathogen, which can persist in the environment for extended periods after treatment and may cause endodontic failure. It is known to produce biofilms, a community of bacteria enclosed within a protective polymeric matrix. This study aimed to establish whether the biofilm formation by Enterococcus faecalis can be inhibited with steralium, co+steralium, and 5% sodium hypochlorite in the root surface environment. Materials and Methods: Extracted human teeth were biomechanically prepared, vertically sectioned, placed in the tissue culture wells exposing the root canal surface to E. faecalis to form a biofilm. At the end of the 3rd and 6th weeks, all groups were treated for 10 minutes with the previously mentioned tested solutions and control and were analyzed qualitatively and quantitatively. Results: Qualitative assay with 3-weeks biofilm showed a complete inhibition of bacterial growth with co+steralium and NaOCl, except steralium and saline, which showed presence of bacterial growth. In quantitative analysis, steralium and saline- treated tooth samples have 57.74 ± 5.39* CFU/ml., 140.71 ± 8.49 CFU/ml. respectively. Qualitative assay with 6-week biofilm showed growth when treated with steralium and saline treated tooth samples have 346.0 ± 78.88* CFU/ml., 127.18 ± 17.84 CFU/ml. respectively whereas co+steralium and NaOCl has shown complete inhibition. Conclusions: co+steralium and 5% sodium hypochlorite showed maximum antibacterial activity against E. Faecalis biofilm formed on tooth substrate. co+steralium showed statistically significant antibacterial activity. The use of co+steralium as a root canal irrigant might prove to be advantageous considering the several undesirable characteristics of NaOCl. Key words: Biofilm, E. faecalis, steralium, co+steralium, NaOCl, root canal irrigant.
Extended calculations for sputtering yield through bombed Iron – target by ( H,D ,T ,He ) ions plasma are accomplished .The calculations include changing the input parameters : the energy of ( H,D ,T ,He ) ions plasma, the hit target angle of Iron, change atomic mass of incident ion. The program TRIM is used to accomplish these calculations. The results show that sputtering yield is directly dependent on these parameters. It can change the incident angle of ( H,D ,T ,He ) ions and energy&n
... Show MoreInelastic longitudinal electron scattering form factors have been calculated for isoscaler transition
T = 0 of the (0+ ®2+ ) and (0+ ®4+ ) transitions for the 20Ne ,24Mg and 28Si nuclei. Model
space wave function defined by the orbits 1d5 2 ,2s1 2 and 1d3 2 can not give reasonable result for
the form factor. The core-polarization effects are evaluated by adopting the shape of the Tassie-
Model, together with the calculated ground Charge Density Distribution CDD for the low mass 2s-1d
shell nuclei using the occupation number of the states where the sub-shell 2s is included with an
occupation number of protons (a ) .
This paper describes DC motor speed control based on optimal Linear Quadratic Regulator (LQR) technique. Controller's objective is to maintain the speed of rotation of the motor shaft with a particular step response.The controller is modeled in MATLAB environment, the simulation results show that the proposed controller gives better performance and less settling time when compared with the traditional PID controller.
In this paper, a new procedure is introduced to estimate the solution for the three-point boundary value problem which is instituted on the use of Morgan-Voyce polynomial. In the beginning, Morgan-Voyce polynomial along with their important properties is introduced. Next, this polynomial with aid of the collocation method utilized to modify the differential equation with boundary conditions to the algebraic system. Finally, the examples approve the validity and accuracy of the proposed method.
This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.
Abstract
The project of balad's major sewerage system is one of the biggest projects who is still in progress in salahulddin province provincial - development plan that was approved in 2013 . This project works in two parts ; the 1st is installing the sewerage networks (both of heavy sewerage & rain sewerage) and the 2nd is installing the life – off units (for heavy sewerage & rain sewerage , as well) . the directorate of salahuiddin is aiming that at end of construction it will be able to provide services for four residential quarters , one of the main challenges that project's management experience is how to achieve thes
... Show MoreIt is frequently asserted that an advantage of a binary search tree implementation of a set over linked list implementation is that for reasonably well balanced binary search trees the average search time (to discover whether or not a particular element is present in the set) is O(log N) to the base 2 where N is the number of element in the set (the size of the tree). This paper presents an experiment for measuring and comparing the obtained binary search tree time with the expected time (theoretical), this experiment proved the correctness of the hypothesis, the experiment is carried out using a program in turbo Pascal with recursion technique implementation and a statistical method to prove th
... Show MoreThe aim of this paper is to design feed forward neural network to determine the effects of
cold pills and cascades from simulation the problem to system of first order initial value
problem. This problem is typical of the many models of the passage of medication throughout
the body. Designer model is an important part of the process by which dosage levels are set.
A critical factor is the need to keep the levels of medication high enough to be effective, but
not so high that they are dangerous.
(3) (PDF) Theoretical calculation of the electronic current at N3 contact with TiO2 solar cell devices. Available from: https://www.researchgate.net/publication/362780274_Theoretical_calculation_of_the_electronic_current_at_N3_contact_with_TiO2_solar_cell_devices [accessed May 01 2023].