A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, with a correlation coefficient of 1 and 0.9999 for PCM and CF, respectively, over the concentration ranges of 15–300 μg/mL (PCM) and 2.5–50 μg/mL (CF). The retention time (
Abstract:
The problem of poverty is one of the most important development challenges facing developing countries including Sudan for several decades. Although many efforts have been made to reduce poverty, however, its rates are increasing, and public policies adopted by the government in this regard remain elusive in achievinging its main objectives or making any significant progress. The purpose of the present study is to analyse poverty in Sudan by identifying its measurement, causes and the factors that have contributed to the increasing poverty rates over the past two decades. Also this study aims at investigating the interim poverty reduction strategy in Sudan as well as evaluates that strategy throug
... Show MoreA procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using t
... Show MoreThe game of volleyball requires the formation of new motor responses, which in turn requires special physical characteristics in the performance of that skill, and the correct and accurate performance during the performance of the skills of passing from the top and smash serve in volleyball cannot be developed or improved without a good level of accuracy and what is required to perform the movements in terms of responses to the defense and attack movements. Therefore, the researchers decided to identify the type of relationship between the motor response speed with the performance accuracy of the skills of passing from the top and the smash serve in volleyball. The research aims to: 1. Identifying the motor response speed of fourth-stage s
... Show MoreMetoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e
... Show MoreIn this research we study a variance component model, Which is the one of the most important models widely used in the analysis of the data, this model is one type of a multilevel models, and it is considered as linear models , there are three types of linear variance component models ,Fixed effect of linear variance component model, Random effect of linear variance component model and Mixed effect of linear variance component model . In this paper we will examine the model of mixed effect of linear variance component model with one –way random effect ,and the mixed model is a mixture of fixed effect and random effect in the same model, where it contains the parameter (μ) and treatment effect (τi ) which has
... Show MoreThe primary aim of this study was to identify the effect of using the simultaneous electronic presentations strategy in teaching basic skills of basketball to second-grade intermediate students. The present study had a parallel group, pre-post experimental design. In the present study the students of the Salah al-Din Intermediate School for the academic year 2020-2021 constituted the research community. A total of 75 students were present in the research community. Out of 75 students 16 students were selected as the participants for the study. The students falling within the age group of 13-14 years were recruited as the study participants, making up a percentage of 21.33 of the total number. Based on the results of th
... Show More