Cyclic Fatigue Resistance of Wave One Gold, F6 SkyTaper, One Curve, and AF Blue R3 NiTi Rotary Instrumentation Systems
...Show More Authors

Objective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to fracture, and the time to failure was recorded in seconds then transformed to minutes. In addition to that the fractured fragment length was evaluated. Results: One-way analysis of variance test showed a significant difference (P< 0.001) in the average values of cycle number and time needed for file fracture and average fractured portion length among all groups. The t-test results indicate a significant difference (P< 0.001) among all groups. Conclusions: The study concluded that with an apical curvature of an artificial canal with an angle curvature of 60, AF Blue R3 and F6 SkyTaper instruments exhibit a higher resistance to cyclic fatigue than One Curve and Wave One Gold files most possibly due to surface and alloy feature variation.

Scopus
Publication Date
Wed Dec 01 2021
Journal Name
Computers &amp; Electrical Engineering
Utilizing different types of deep learning models for classification of series arc in photovoltaics systems
...Show More Authors

View Publication
Crossref (15)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Impact of using Double Layers Perforated Liners on the Acoustic Treatments of the Combustor Systems
...Show More Authors

The response of the combustor’s liner to the air-flow that passes through it is the key reason for the combustion chambers noise, hence the instabilities of those chambers that decreases the mechanical efficiency of such sections, by increased its mechanical vibrations, which increases the failure rate created during originating of the cracks spreading by the shakes producing by the series of high-level frequencies. Accordingly, any work debating the impact of the context of liners in the combustion chamber can provide grasping for the combustion noise generated by the undesirable vibrations, and benefits the industrial firms to design an ideal production procedure which increases the lifespan of the combustor. The goal of this wo

... Show More
Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Impact of using Double Layers Perforated Liners on the Acoustic Treatments of the Combustor Systems
...Show More Authors

The response of the combustor’s liner to the air-flow that passes through it is the key reason for the combustion chambers noise, hence the instabilities of those chambers that decreases the mechanical efficiency of such sections, by increased its mechanical vibrations, which increases the failure rate created during originating of the cracks spreading by the shakes producing by the series of high-level frequencies. Accordingly, any work debating the impact of the context of liners in the combustion chamber can provide grasping for the combustion noise generated by the undesirable vibrations, and benefits the industrial firms to design an ideal production procedure which increases the lifespan of the combustor. The goal of this work is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 01 2012
Journal Name
The Journal Of Engineering Research [tjer]
Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers
...Show More Authors

 This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

View Publication
Scopus (10)
Crossref (4)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Histological and Physiological Studies on the Long-term Effect of Different Concentrations of Energy Drink (Tiger) on the Renal and Hepatic Systems of Young Mice
...Show More Authors

The present study aims to investigate the long-term histopathological, and physiological effects of different concentrations of a commercially available energy drink (Tiger) on liver and kidney of young mice. Sixteen Balb/c male mice,6 -week old, were divided into 4 groups (n=4). Two groups consumed the energy drink at a concentration of 28µl energy drink/ml water. One group were killed after 10 days (T1), another group were killed after 20 days (T2). Other group of mice consumed the energy drink at a final concentration of 14µl/ml for 20 days (T3). The last group was provided only with water and served as control. Mice of all groups drank around 3 ml per day. The histopathological study on liver of treated groups showed many changes s

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Journal Of Pure And Applied Microbiology
Antibiotic Resistance of Isolated Gram Negative Bacilli from Different Clinical Sample in a Central Teaching Hospital of Pediatric in Baghdad
...Show More Authors

The number of infections caused by microorganisms is increasing significantly over the last few years. A total of 140 patients admitted to the central teaching hospital of pediatrics from the 1st of Jun 2017 to 31 October 2017. The Clinical samples was processed from culture and sensitivity testing. Antibiotic discs used for gram negative isolates. The most prevalent gram negative isolates included Escherichia coli 63 (45.0 %), Pseudomonas spp. 21 (15.0 %), Klebsiella spp. 19 (13.6 %) predominantly. Escherichia coli were the most prevalent isolates from urine 45 (71.4 %), Klebsiella spp. 11 (57.9 %) and Enterobacter spp. 11 (68.8 %) followed by Escherichia coli 10 (15.9 %) predominant from blood. 68 (48.6 %) of specimens were urine, 47 (33.

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Feb 28 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of recent adhesive onlay fabrication techniques on the fracture resistance of endodontically treated premolars (An in vitro study)
...Show More Authors

Background: Endodontically treated teeth have low resistance to fracture against occlusal forces. The strengthening effect of bonded esthetic onlay restoration on weakened tooth has been reported. This study aimed to assess the fracture resistance of endodontically treated premolars restored with composite with and without cuspal coverage by using direct and indirect techniques. Indirect technique done by CAD/CAM system (computer aided design –computer aided manufacturer) and laboratory processing. Material and methods: Forty human extracted maxillary premolars of approximately comparable sizes were divided into four groups: Group (A): Ten endodontically treated teeth directly filled with Filtek Z250xt without cuspal coverage. Group

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 05 2025
Journal Name
Journal Of Oral Biology And Craniofacial Research
The effect of thermocycling on fracture resistance of zirconia crowns cemented with polylysine modified resin cements (Comparative in vitro study)
...Show More Authors

ABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS

... Show More
View Publication
Scopus Crossref
Publication Date
Fri Jan 05 2018
Journal Name
International Journal Of Science And Research (ijsr)
Comparative Study of Some Antibiotic Resistance, Extended Spectrum ß-Lactamases (ESBLs), Metallo ß-Lactamases (MBLs) Produced in Pseudomonas aeruginosa Isolated from Clinical and Food Samples
...Show More Authors

A total number of 33 isolates of Pseudomoans aeruginosa were collected from different clinical samples, such as: burn, wound and urine from patients attending Al-Yarmouk teaching hospital and some private clinical laboratories in Baghdad city through the period from October to December 2016. On the other hand, 21 isolates of P. aeruginosa were collected from 38 different food samples; such as: vegetables and fruits, from different local markets in Baghdad city during the period from November to December 2016. All isolates were identified by using different bacteriological and biochemical assays and confirmed by Vitek-2 identification system. The antimicrobial susceptibility test for clinical and food isolates towards 17 antimicrobial a

... Show More
Publication Date
Sat Feb 28 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Fracture resistance of endodontically treated premolars with extensive MOD cavities restored with different composite restorations (An In vitro study)
...Show More Authors

Background: This in vitro study evaluated the fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different composite restorations (Low-shrinkage Filtek P90, nanohybrid Filtek Z250 XT and SDR bulk fill). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Fifty human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into five groups of ten teeth each (n=10): (Group 1) intact control group, (Group 2) unrestored teeth with endodontic treatment, (Group 3) resto

... Show More
View Publication Preview PDF