Objective: This in vitro study is aimed to compare and evaluate the cyclic fatigue of four varying NiTi rotary instrumentation systems. Method: In this study, four types of rotary files were used in four groups (10 files for each group), namely, Group A: Wave One Gold; Group B: AF Blue R3; Group C: One Curve; Group D: F6 SkyTaper. These groups were evaluated by a cyclic fatigue apparatus to measure cyclic fatigue resistance within the artificial metallic simulating canal that has a 60 angle of curvature, the curvature radius was 5 mm, whereas the inner diameter of the canal was 1.5 mm. All the files were rotated in artificial canals until they fracture. The resistance to cyclic fatigue was determined by counting the number of cycles to fracture, and the time to failure was recorded in seconds then transformed to minutes. In addition to that the fractured fragment length was evaluated. Results: One-way analysis of variance test showed a significant difference (P< 0.001) in the average values of cycle number and time needed for file fracture and average fractured portion length among all groups. The t-test results indicate a significant difference (P< 0.001) among all groups. Conclusions: The study concluded that with an apical curvature of an artificial canal with an angle curvature of 60, AF Blue R3 and F6 SkyTaper instruments exhibit a higher resistance to cyclic fatigue than One Curve and Wave One Gold files most possibly due to surface and alloy feature variation.
In this study, six square reinforced concrete flat plates with dimensions of (1500×1500×100) mm were tested under a concentrated load applied on a column located at the center of the slabs. One of these slabs was the control specimen, whereas, in the others, steel angles (steel collars) were used, fixed at the connection region between the slab and the column to investigate the effect of the presence of these collars on punching shear strength. Five thicknesses were used (4, 5, 6, 8, 10mm) with constant legs of angles (75×75) mm of the steel collars to investigate the effects on the punching shear resistance with respect to the control slab. The results of the experimental study show that the punching shear resistance increased b
... Show MoreIn this work, the copper metal was treated using Nd:YAG laser with energy 1Joul to enhance corrosion resistance and improve surface properties. The copper metal has many applications in industry as well as water, oil and gas pipes. The same conditions, (laser power density, scan speed, distance between paths, medium gas-air) were applied in the laser surface treatment, After laser treatment, the samples microstructures were investigated using optical microscope (OM) to examine micro structural changes due to laser irradiation. Specimen surfaces were investigated using atomic force microscopy (AFM), X-ray diffraction (XRD), macro hardness, and corrosion test before and after laser treatment to
... Show MoreThe electrochemical behavior of Al-17%Si alloy is investigated in 3.5wt% NaCl solution. Many alloys with addition of the different wt% magnesium metal of 1wt%, 2%, 3wt% ,4.5wt% ,and 9wt% were prepared by gravity die casting . The microstructures of prepared alloys were examined by optical and SEM microscopes. Corrosion behavior was investigated by using potentiostat instrument under static potentials test and corrosion current was recorded to determine corrosion resistance of all prepared samples. It was found that the addition of Mg metal improves the corrosion resistance of Al-17%Si alloy in 3.5%NaCl solution. The alloy containing 1%Mg shows less corrosion rate than the others while the alloys containing 4.5%Mg, 9%Mg content have
... Show MoreBackground: Pseudomonas aeruginosa is a devious pathogen with the tendency to prompt many acute and serious chronic diseases. This study aims to detect novel genes (Toxins-Antitoxins II system), especially; higB and higA encoded from P. aeruginosa by PCR technique and the relation between these genes and antibiotic resistance of P. aeruginosa. Methods: This study detected 50 isolates of P. aeruginosa from distinct clinical sources. The most common origin of isolates was (44%) burn swabs, (22%) urine culture, (12%) wound swabs, (14%) sputum, and (8%) ear swabs. The bacteria were isolated using implantation MacConkey agar and blood agar, as well as biochemical tests including oxidase test, catalase test then VITEK-2 System of P. aerug
... Show MoreAbstract: Aluminum alloys grade 6061-T6 are characterized by their excellent properties and processing characteristics which make them ideal for varieties of industrial applications under cyclic loading, aluminum alloys show less fatigue life than steel alloys of similar strength. In the current study, a nanosecond fiber laser of maximum pulse energy up to 9.9 mJ was used to apply laser shock peening process (LSP) on aluminum thin sheets to introduce residual stresses in order to enhance fatigue life under cyclic loading Box-Behnken design (BBD) based on the design of experiments (DOE) was employed in this study for experimental design data analysis, model building and optimization The effect of working parameters spot size (ω), scannin
... Show MorePurpose This study was design to investigate of Purpose This study was design to investigate of P. aeruginosa, an example of Gram-negative bacteria, in seven primary and secondary schools of Baghdad city, and the effects of Ethanol and Dettol of P. aeruginosa biofilm. Design/methodology/approach Seventy swabs were collected from seven primary and secondary schools of Baghdad city, Iraq, during November -December 2022. Swabs were collected from classes desk, doors handles, students hands and water taps. Standard microbiological testing methods were used on the samples for isolation and identification. The ability of bacteria to form biofilm and the effects of Ethanol and Dettol on “preformed” biofilms was examined by microtiter plate wi
... Show MoreLaser shock peening (LSP) is deemed as a deep-rooted technology for stimulating compressive residual stresses below the surface of metallic elements. As a result, fatigue lifespan is improved, and the substance properties become further resistant to wear and corrosion. The LSP provides more unfailing surface treatment and a potential decrease in microstructural damage. Laser shock peening is a well-organized method measured up to the mechanical shoot peening. This kind of surface handling can be fulfilled via an intense laser pulse focused on a substantial surface in extremely shorter intervals. In this work, Hydrofluoric Acid (HF) and pure water as a coating layer were utilized as a new technique to improve the properti
... Show MoreCognitive-behavioral therapy is one of the most important relatively recent; treatment programs that attempt to modify behavior and control psychological disorders by modifying the individual's thinking style and awareness of himself and his environment, and cognitive reconstruction by replacing negative thoughts with positive ones. The current study aimed to know the effectiveness of a cognitive behavioral treatment program in reducing nervous fatigue among mothers of children with cerebral palsy. The sample on which the nervous fatigue scale was applied consisted of (30) mothers whose son suffers from cerebral palsy, and the results indicated that (24) mothers suffer from nervous fatigue. This sample was divided
... Show MoreThe aim of this work is to study the influence of the type of fiber glass –mat on fatigue behavior of composite material which is manufactured from polyester and E-glass (woven roving, chopped strand mat (CSM)) as a laminate with a constant fiber volume fraction (VF) of 33%. The results showed that the laminates reinforced with E-glass (woven roving) [0/90, ±45.0/90] and [0/90, CSM, 0/90] have lower fatigue strength than the laminates reinforced with E-glass [0/90]3,[CSM]3 and [CSM, 0/90, CSM] although they had different tensile strength; the best laminate was [0/90]3 .