Preferred Language
Articles
/
jRZrVocBVTCNdQwC1Ebk
Estimation of shock wave position in plasma plume using Sedov-Taylor model
...Show More Authors

In this work, radius of shock wave of plasma plume (R) and speed of plasma (U) have been calculated theoretically using Matlab program.

Publication Date
Wed Jan 01 2020
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees20
Theoretical estimation of the trapping reaction rate for deuteron-deuteron fusion in nickel metal using Bose-Einstein condensates phenomena
...Show More Authors

A mathematical model has been introduced to investigate the effect of nuclear reaction constant ( A ), probability of the BEC ground state occupation Ω i, nD is the number density of deuteron (d) and the overall number of nuclei ND on the total nuclear d-d fusion rate (R). Under steady-state of the condensates of Bose-Einstein, the postulate of quantum theory and Bose-Einstein theory were applied to evaluate the total nuclear (d-d) fusion rate trapping in Nickel-metal The total nuclear fusion rate trapping predicts a strong relationship between astrophysical S-factor and masses of Nickel. The reaction rate trapping model was tested on three reaction d(d,p)T, d(d, n)3He and d(d, 4He)Q = 23.8MeV respectively. The reaction rate has described

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri Jun 17 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Estimation the Safety of Parenteral Resveratrol in Mice
...Show More Authors

   Resveratrol is polyphenolic compound has many biochemical and biological effects on several organs. Therefore, resveratrol can be used to treat many diseases. The aim was to evaluate resveratrol safety when used in a parenteral single bolus dose. This study was conducted on 60 mice (30 males and 30 females). Each male and female mice divided into 6 groups (five mice per group). All mice groups given 1% DMSO and five different doses of resveratrol (5, 2.5, 1.25, 0.625, 0.312) gm/kg intraperitonially given to five groups respectively. The mice were continuously monitored during 14 days. The number of deaths, changes in general behavior, changes in physiological activity, and signs of toxicity were reported. On day 15 blood was

... Show More
View Publication Preview PDF
Scopus (8)
Scopus Crossref
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Estimation of Volumetric Mass Transfer Coefficient in Bioreactor
...Show More Authors

 

This study is concentrated to investigate the effects of aeration and stirring speed on the volumetric mass transfer coefficient (KLa). A dynamic technique was used in estimating KLa values in order to achieve the aim of this study.

This study was done in 10L bioreactor by using two medias:-

  1. Dionized water
  2. Xanthan solution (1 g /L)

Moreover, the research covered a comparison between the obtained values of KLa.

The Xanthan solution was used because of its higher viscosity in comparison with water. It behaves similarly to the cultivation medium when organisms are cultivated in a bioreactor. Growth of organisms in the reactor l

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 28 2024
Journal Name
Journal Of The Pakistan Medical Association
Investigating the correlation of the second derivative of digital pulse wave (DPW) with QT variability index in women
...Show More Authors

Objective: To determine the correlation between the second derivative of digital pulse wave and the QT variability index. Method: The cross-sectional study was conducted from October 2021 to May 2022 at the Department of Physiology, College of Medicine, University of Mustansiriyah, Baghdad, Iraq, and comprised healthy women. Samples were raised by simple random technique. Digital pulse waves were captured using a fingertip pulse wave transducer. Lab Chart Pro version 7.2 was used to automatically detect and quantify the amplitude of A, B, C, D and E waves expressed by the second derivative. QT interval of each beat was recorded by electrocardiogram, and was calculated automatically via Lab chart Pro version 7.2 without averaging. D

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative Study of The Amount of Apically Extrusion Of Debris During Root Canal Preparation Using Wave Oneâ„¢, Trushape 3Dâ„¢, Hyflexâ„¢ CM and One Shapeâ„¢ Instrumentation Systems (An In Vitro Study)
...Show More Authors

Background: Many types of instruments and techniques are used in the instrumentation of the root canal system. These instruments and techniques may extrude debris beyond the apical foramen and may cause post-instrumentation complications. The aim of this study was to evaluate the amount of apically extruded debris resulted by using 4 types of nickel-titanium instruments (WaveOne, TRUShape 3D conforming files, Hyflex CM, and One Shape files) during endodontic instrumentation. Materials and methods: Forty freshly extracted human mandibular second premolar with straight canals and a single apex were collected for this study. All teeth were cut to similar lengths. Pre-weighted glass vials were used as collecting containers. Samples were randoml

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Aug 01 2019
Journal Name
مجلة العلوم الاقتصادية والإدارية
Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
...Show More Authors

Improving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application

Publication Date
Wed Dec 13 2017
Journal Name
Al-khwarizmi Engineering Journal
Design and Simulation of L1-Adaptive Controller for Position Control of DC Servomotor
...Show More Authors

This paper presents L1-adaptive controller for controlling uncertain parameters and time-varying unknown parameters to control the position of a DC servomotor. For the purpose of comparison, the effectiveness of L1-adaptive controller for position control of studied servomotor has been examined and compared with another adaptive controller; Model Reference Adaptive Controller (MRAC). Robustness of both L1-adaptive controller and model reference adaptive controller to different input reference signals and different structures of uncertainty were studied. Three different types of input signals are taken into account; ramp, step and sinusoidal. The L1-adaptive controller ensured uniformly bounded

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
Electron density spectroscopic measurement in Al laser induced plasma
...Show More Authors

Plasma generated by a 1064 nm pulsed Nd: YAG laser with pulse duration of 10 ns concentrated onto an Al solid target under vacuum pressure was examined spectroscopically. The temperature and electron density specifying the plasma were measured by time-resolved spectroscopy of neutral atom and ion line emissions in the time period range of 300–2000 ns. An echelle spectrograph is utilized to appear the plasma emission lines. The temperature was obtained using the spectral line comparison method and the electron density was calculated using the Stark Broadening (SB) method. The electron density was characterized as a function of laser pulse energy. The time range where the plasma is optically thin and is also in local thermodynamic equilibri

... Show More
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study for plasma parameters in co-sputtering system
...Show More Authors

In this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Aug 18 2020
Journal Name
Journal Of Mechanics Of Continua And Mathematical Sciences
THE COMPARISON OF THE METHODS ESTIMATING THE FRACTIONAL DIFFERENCES OF PARAMETER AND ITS DEPENDENCE ON ESTIMATION THE BEST LINEAR MODEL OF TIME SERIES IN THE ENVIRONMENTAL FIELD
...Show More Authors

View Publication
Crossref