Preferred Language
Articles
/
jBfbLJMBVTCNdQwCac6Q
Neutrophil/lymphocyte and platelet/lymphocyte ratios as potential markers of disease activity in patients with Ankylosing spondylitis: a case-control study
...Show More Authors
Abstract<sec> <title>Background

The neutrophil/ lymphocyte ratio (NLR) and platelet/lymphocyte ratio (PLR) have the potential to be inflammatory markers that reflect the activity of many inflammatory diseases. The aim of this study was to evaluate the NLR and PLR as potential markers of disease activity in patients with ankylosing spondylitis.

Methods

The study involved 132 patients with ankylosing spondylitis and 81 healthy controls matched in terms of age and gender. Their sociodemographic data, disease activity scores using the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI), erythrocyte sedimentation rate (ESR), and white blood cell, neutrophil, lymphocyte and platelet counts were recorded. The patients with ankylosing spondylitis were further divided according to their BASDAI scores into patients with inactive disease (BASDAI < 4) and patients with active disease (BASDAI ≥4). The correlations between the NLR, PLR and disease activity were analysed.

Results

There was a statistically significant difference in the NLR and PLR between the active and inactive ankylosing spondylitis patients (2.31 ± 1.23 vs. 1.77 ± 0.73, p = 0.002), (142.04 ± 70.98 vs. 119.24 ± 32.49, p <  0.001, respectively). However, there was no significant difference in both the NLR and PLR between the healthy control group and ankylosing spondylitis patients (p > 0.05). In addition, the PLR was significantly higher in both the active and inactive groups compared to those in the healthy control group (142.04 ± 70.98 vs. 99.32 ± 33.97, p = 0.014), (119.24 ± 32.49 vs. 99.32 ± 33.97, p = 0.019). The BASDAI scores were positively correlated with the PLR (r = 0.219, p = 0.012) and the NLR, but they were not statistically significant with the later (r = 0.170, p = 0.051). Based on the ROC curve, the best NLR cut-off value for predicting severe disease activity in ankylosing spondylitis patients was 1.66, with a sensitivity of 61.8% and a specificity of 50.6%, whereas the best PLR cut-off value was 95.9, with a sensitivity of 70.9% and a specificity of 55.5%.

Conclusion

The PLR may be used as a useful marker in the assessment and monitoring of disease activity in AS together with acute phase reactants such as the ESR.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Synthesis of anti-corrosion polymers from thiadiazole
...Show More Authors
Abstract<p>One of the biggest problems facing many industries particularly oil, is the problem of corrosion, where the metal parts under the influence of the vital factors are eroded during use and storage, therefore, to lift the metal’s ability and to protect it against corrosion, corrosion inhibitors are used. For the first time in this research, polymers which contain sulfur - heterocyclic ring with a thiadiazole base were made. Anti- corrosion polymers were made on two stages, in the first stage, thiadiazole was made from hydrazine hydrate reaction to carbon disulfide, afterwards the first product was reacted with an excess of hydrazine. In the second stage, polymers were prepared by the r</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Apr 21 2016
Journal Name
Australian Journal Of Basic And Applied Sciences
Sensing Properties of (In2O3:Eu) Thin Films
...Show More Authors

Thin films of iridium doped indium oxide (In2O3:Eu)with different doping ratio(0,3,5,7,and 9%) are prepared on glass and single crystal silicon wafer substrates using spray pyrolysis method. The goal of this research is to investigate the effect of doping ratio on of the structural, optical and sensing properties . The structure of the prepared thin films was characterized at room temperature using X-ray diffraction. The results showed that all the undoped and doped (In2O3:Eu)samples are polycrystalline in structure and nearly stoichiometric. UV-visible spectrophotometer in the wavelength range (200-1100nm)was used to determine the optical energy gap and optical constants. The optical transmittance of 83% and the optical band gap of 5.2eV

... Show More
Publication Date
Fri Jun 01 2018
Journal Name
Journal Of Engineering
Derivation of Operation Rule for Ilisu Dam
...Show More Authors

Tigris River water that comes from Turkey represents the main water resource of this river in Iraq. The expansion in water river implementations has formed a source of trouble for the workers in the water resources management field in Iraqi. Unfortunately, there is no agreement between Iraq and Turkey till now to share the water of this international river. Consequently, the optimal operation of water resources systems, particularly a multi-objective, multi-reservoir, is of the most necessity at the present time.

 In this research two approaches, were used the dynamic programming (DP) approach and simulation model to find the optimal monthly operation of Ilisu Dam (from an Iraqi point of view) through a comp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Baghdad Science Journal
Thermoluminescence dosimetry of mixed neutron – gamma fields
...Show More Authors

The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.

View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
GENERATION OF MPSK SIGNAL USING LOGIC CIRCUITS
...Show More Authors

The traditional technique of generating MPSK signals is basically to use IQ modulator that involves analog processing like multiplication and addition where inaccuracies may exist and would lead to imbalance problems that affects the output modulated signal and hence the overall performance of the system. In this paper, a simple method is presented for generating the MPSK using logic circuits that basically generated M-carrier signals each carrier of different equally spaced phase shift. Then these carriers are time multiplexed, according to the data symbols, into the output modulated signal.

View Publication Preview PDF
Crossref
Publication Date
Fri Mar 01 2013
Journal Name
International Journal Of Recent Research And Review
Electrical Discharges Characterization of Planar Sputtering System
...Show More Authors

Abstract: A home-made dc sputtering is characterized by cathode potential of 250-2500 V and sputtering gas pressures of (3.5×10-2 – 1.5) mbar. This paper studies in experiment the breakdown of argon, nitrogen, and oxygen in a uniform dc electric field at different discharge gaps and cathode potentials. Paschen curves for Argon, Nitrogen, and oxygen are obtained by measuring the breakdown voltage of gas within a stainless steel vacuum chamber with two planar, stainless steel electrodes. The Paschen curves in Ar, N2, and O2 gases show that the breakdown voltage between two electrodes is a function of pd (The product of the pressure inside the chamber and distance between the electrodes). Current-voltage characteristics visualization of the

... Show More
Preview PDF
Publication Date
Mon Jan 17 2011
Journal Name
Journal Of Engineering
MEASUREMENT OF TRANSMITED VIBRATION TO TRACTOR SEAT
...Show More Authors

A field experiment was conducted at experimental field of Mechanization Agriculture , the College of Agriculture , Abu – Ghraib , University of Baghdad .To measure transmitted vibration to seat tractor during operation tillage , mold board plow with New Holland 66-S- 80 tractor as one machinery unit , Soil was treated at soil constant moisture ( 18 – 20 % ) with two depths of plowing (15 and 20 cm ) and three speed of tractor 2.0 , 3.5, 6.8 km / h . Three main dimensions in seat tractor measurement vertical, longitudinal and lateral acceleration. Split plot design under completes block design with three replicates .

Preview PDF
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Energy band diagram of In2O3/ Si heterojunction
...Show More Authors

Crystalline In2O3 Thin films have been prepared by flash evaporation. We have studied the crystal structure of as deposited at 303K and annealed at 523K using X-ray diffraction. The Hall Effect measurements confirmed that electrons were predominant charges in the conduction process (i.e n-type).It is found that the absorption coefficient of the prepared films decreases with increasing Ta. The d.c conductivity study showed that the conductivity increase with increasing Ta , whereas the activation energy decreases with increasing Ta. Also we study the barrier tunneling diode for In2O3/Si heterostructure grown by Flash evaporation technique. (capacitance-voltage C-V) spectroscopy measurements were performed at 303 K and at the annealing temper

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Anodic Polarization of Anodized Aluminum Alloy 5052
...Show More Authors

Aluminum alloy 5052 had been anodized by sulfuric acid as an electrolyte under constant voltage and the anodic oxide film produce will be testing by potentiostatic anodic polarization .Two variables, which were considered as important variables, were studied. These variables are anodizing time 15,30 min. and sealing time 10,20 min., and the test by potentiostatic anodic polarization through electro chemical polarization measurements in solutions of 1N na2so4 ( PH= 1 ). The results are discussed in light of the rate of ionic current flow through the coating during anodic polarization measurements.

View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
STATIC PERFORMANCE CHARACTERISTICS OF VORTEX RATE SENSOR
...Show More Authors

The vortex rate sensor is a fluidic gyroscope with no moving parts and can be used in very difficult
conditions like radiation, high temperature and noise with minimum cost of manufacturing and
maintenance. A vortex rate sensor made of wood has been designed and manufactured to study
theoretically and experimentally its static performance .A rig has been built to carry out the study,
the test carried out with three different air flow rates (100, 150, and 200 l/min).The results show that
the relation between the differential pressure taken from the sensor pickoff points and the angular
velocity of the sensor was linear.The present work involved theoretical and experimental study of
vortex rate sensor static characteri

... Show More
View Publication Preview PDF
Crossref