This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks of treatment, significant recovery was observed in shallow enamel. Further improvement in shallow WSL after 8 weeks of treatment with biorepair mouthwash was observed compared to Sensodyne and the control group. Splat mouthwash is more effective than other mouthwashes in remineralizing two depths of WSLs at different time points. Keywords: DIAGNOdent pen, Shallow enamel, Deep enamel, white spot lesion.
End Stage Renal Disease is a well-known global public health problem. Maintenance hemodialysis is considered a life-saving treatment for patients with such disease. This treatment method that requires patients to be adherent to hemodialysis attendance, dietary and fluid recommendations as well as adherence to prescribed medications to ensure success. The aim of the current study was to assess adherence, perception, and counseling among hemodialysis patients to different modalities of treatment (fluid restriction, dietary recommendations, medications, and hemodialysis schedules). A cross-sectional study carried out on hemodialysis patients who attended to the dialysis centers at al- Karama teachi
... Show MoreABSTRACT Background: resin cement type and intraoral temperature fluctuations may affect the fracture performance of successful zirconia restorations. To fill this gap, the purpose of this study is to evaluate and compare the influence of thermocycling on fracture resistance and mode of failure of monolithic zirconia crowns luted with Rely X™ U200 and BreezeTMself-adhesive resin cements as well as imply the effect of adding 2 % of polylysine (PLS) to these cements. Materials: 64 maxillary premolars were milled out of zirconia blocks using CAD/CAM milling system. They were divided into four groups (n = 16) according to the cement type. Four different resin cements were used (RelyXTMU200, Breeze™, RelyX™ U200 with 2 % PLS
... Show MoreThe current study deals with estimating the protein concentration and the effect of fish weight on protein concentration values in red and white muscles in two different regions ( R1 : Anterior region lies 2 cm behind the head and R2: posterior region lies 2cm from caudal fin (in two types of bony fish, namely common carp (Cyprinus carpio) and Nile tilapia (Oreochromis niloticus). Samples were collected from Karmat Ali river- north of Basrah between October 2019 and February 2020. The protein was extracted using protein extraction buffer, the current study show that the average of protein concentration in red muscles of Nile tilapia ranged between 7.74-7.4 mg / ml and ( 6.8-8.85 mg / ml) in R1 and R2 region re
... Show MoreTo show the impact of 790-805 nm diode laser irradiations on wound healing as a supplementary treatment in women underwent episiotomies, and to assess the laser parameters that were used .Material and methods: Eighteen female patients were included in this study; all of them underwent mediolateral episiotomy. Ten patients received laser therapy- diode laser (K Laser) (790-805) nm in CW mode of operation (and eight patients were the control group. Spot size of 8mm, time for exposure for each spot was 30 seconds. The power used was 0.6 W .The power density for each spot of treatment was 1.19 W/cm2 per session (non contact mode of application of laser therapy).The group studied received 2 sessions of laser radiation, day 4, and day 8 after
... Show MoreIt is commonly known that Euler-Bernoulli’s thin beam theorem is not applicable whenever a nonlinear distribution of strain/stress occurs, such as in deep beams, or the stress distribution is discontinuous. In order to design the members experiencing such distorted stress regions, the Strut-and-Tie Model (STM) could be utilized. In this paper, experimental investigation of STM technique for three identical small-scale deep beams was conducted. The beams were simply supported and loaded statically with a concentrated load at the mid span of the beams. These deep beams had two symmetrical openings near the application point of loading. Both the deep beam, where the stress distribution cannot be assumed linear, and the ex
... Show MoreIn this paper, the memorization capability of a multilayer interpolative neural network is exploited to estimate a mobile position based on three angles of arrival. The neural network is trained with ideal angles-position patterns distributed uniformly throughout the region. This approach is compared with two other analytical methods, the average-position method which relies on finding the average position of the vertices of the uncertainty triangular region and the optimal position method which relies on finding the nearest ideal angles-position pattern to the measured angles. Simulation results based on estimations of the mobile position of particles moving along a nonlinear path show that the interpolative neural network approach outperf
... Show MoreA characteristic study of a passively Q-switched diode pumped solid state laser system is presented in this work. For laser a comparison study for the theoretically calculated results with a simulation results using a software which calculates the Q-switched solid state laser parameters was such as energy, peak power and pulse width were performed. There was a good agreement between our theoretical calculations and the simulation values.