Kurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.
The current research aimed to analyze the importance, correlation and the effect of independent variables represented by marketing variables on the dependent variable represented by local brand, through taking ENIEM as a model for this study, which represents a sensitive sector for the Algerian consumer. The results of the study evinced that the Algerian consumer has a positive image toward the brand ENIEM given marketing variables which has acquired considerable importance to this consumer. Also, the results of this study showed a statistically significant correlation between marketing variables and good perception toward the brand ENIEM, at the same time, the existence of a statistically significant effect for each of these variables o
... Show MoreThis work describes, selenium (Se) films were deposited on clean glass substrates by dc planar magnetron sputtering technique.The dependence of sputtering deposition rate of Se film deposited on pressure and DC power has been studied. The optimum argon pressure has range (4x10-1 -8x10-2 )mbar. The optical properties such as absorption coefficient (α) was determined using the absorbance and transmission measurement from UnicoUV-2102 PC spectrophotometer, at normal incidence of light in the wavelength range of 200-850 nm. And also we calculated optical constants(refractive index (n), dielectric constant (εi,r), and Extinction coefficient (κ) for selenium films.
This research analyzes the level of the short circuit effect of the Iraqi super network and decides the suitable location for the High Voltage Direct Current (HVDC) connections in order to obtain the best short circuit reduction of the total currents of the buses in the network. The proposed method depends on choosing the transmission lines for Alternating current (AC) system that suffers from high Short Circuit Levels (SCLs) in order to reduce its impact on the transmission system and on the lines adjacent to it and this after replacing the alternating current (AC) line by direct current (DC) line. In this paper, Power System Simulator for Engineering (PSS/E) is used to model two types of HVDC lines in an effective regi
... Show MoreRoaming data is an important source of information about the political and social activities of a country. And this is true for Iraq situation after 2003 when the mobile companies started their business. In this paper, data of subscribers roamed onto foreign networks (inbound roamers) is collected; it consists of the name of the Radio Control Point, the counter dealing with this type of information, Mobile Network Code/Mobile Country Code tupel. This data is processed. Results obtained out of this process show the classification of the inbound roamers (according to their countries) during the occupation period (2008-2009). These results reflect the political situation of Iraq at that time. Information resulted from this proc
... Show More