Preferred Language
Articles
/
jBcpWZABVTCNdQwCeodK
Calibrated Full-Waveform Airborne Laser Scanning for 3D Object Segmentation
...Show More Authors

Segmentation of urban features is considered a major research challenge in the fields of photogrammetry and remote sensing. However, the dense datasets now readily available through airborne laser scanning (ALS) offer increased potential for 3D object segmentation. Such potential is further augmented by the availability of full-waveform (FWF) ALS data. FWF ALS has demonstrated enhanced performance in segmentation and classification through the additional physical observables which can be provided alongside standard geometric information. However, use of FWF information is not recommended without prior radiometric calibration, taking into account all parameters affecting the backscatter energy. This paper reports the implementation of a radiometric calibration workflow for FWF ALS data, and demonstrates how the resultant FWF information can be used to improve segmentation of an urban area. The developed segmentation algorithm presents a novel approach which uses the calibrated backscatter cross-section as a weighting function to estimate the segmentation similarity measure. The normal vector and the local Euclidian distance are used as criteria to segment the point clouds through a region growing approach. The paper demonstrates the potential to enhance 3D object segmentation in urban areas by integrating the FWF physical backscattered energy alongside geometric information. The method is demonstrated through application to an interest area sampled from a relatively dense FWF ALS dataset. The results are assessed through comparison to those delivered from utilising only geometric information. Validation against a manual segmentation demonstrates a successful automatic implementation, achieving a segmentation accuracy of 82%, and out-performs a purely geometric approach.

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Gamma Irradiation Effects on Energy Transfer Parameters for Acrvlaven – Rhodamine19 Binary Laser Dye Mixtures
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Physics: Conference Series
Gamma Irradiation Effects on Energy Transfer Parameters for Acrvlaven – Rhodamine19 Binary Laser Dye Mixtures
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Synthesis of gold nanoparticles by laser ablation on porous silicon for sensing CO2 gas
...Show More Authors

In this research, porous silicon (PS) prepared by anodization etching on surface of single crystalline p-type Si wafer, then Gold nanoparticle (AuNPs) prepared by pulsed laser ablation in liquid. NPs deposited on PS layer by drop casting. The morphology of PS, AuNPs and AuNPs/PS samples were examined by AFM. The crystallization of this sample was characterized by X-ray diffraction (XRD). The electrical properties and sensitivity to CO2 gas were investigated to Al/AuNPs/PS/c-Si/Al, we found that AuNPs plays crucial role to enhance this properties.

View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jul 20 2022
Journal Name
Journal Of Materials Engineering And Performance
High Speed Shock Peening by Fiber Laser for Al Alloy 6061-T6 Thin Sheets
...Show More Authors

Under cyclic loading, aluminum alloys exhibit less fatigue life than steel alloys of similar strength and this is considered as Achilles's heel of such alloys. A nanosecond fiber laser was used to apply high speed laser shock peening process on thin aluminum plates in order to enhance the fatigue life by introducing compressive residual stresses. The effect of three working parameters namely the pulse repetition rate (PRR), spot size (ω) and scanning speed (v) on limiting the fatigue failure was investigated. The optimum results, represented by the longer fatigue life, were at PRR of 22.5 kHz, ω of 0.04 mm and at both v's of 200 and 500 mm/sec. The research yielded significant results represented by a maximum percentage increase in the fa

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between diode laser and scalpel for lip lengthening in patients with gummy smile
...Show More Authors

Background: lip lengthening procedure is one of the surgical options for the correction of gummy smile in patients with short upper lip. Methods: A comparative clinical study was conducted on 15 patients requiring lip lengthening procedure for the esthetic correction of excessive gingival exposure with gummy smile. Scalpel was used in seven patients and diode laser in the remaining eight patients. Under infiltration anesthesia, about one cm strip of mucosa was excised at the vestibular depth and the mucosa of the lip was sutured to the alveolar mucosa. Results: The diode laser group demonstrated less postoperative pain and swelling. Regarding postoperative ecchymosis, three patients in the scalpel group developed ecchymosis and no cases

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat Oct 28 2023
Journal Name
Journal Of Optics
Advancements and challenges in pulsed laser-deposited hydrophobic CeO2 film for broadband antireflection applications
...Show More Authors

Due to the remarkable progress in photovoltaic technology, enhancing efficiency and minimized the costs have emerged as global challenges for the solar industry. A crucial aspect of this advancement involves the creation of solar cell antireflection coating, which play a significant role in minimizing sunlight reflection on the cell surface. In this study, we report on the optimization of the characteristics of CeO2 films prepared by pulsed laser deposition through the variation of laser energy density. The deposited CeO2 nanostructure films have been used as an effective antireflection coating (ARC) and light-trapping morphology to improve the efficiency of silicon crystalline solar cell. The film’s thickness increases as laser fluence i

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Aip Conference Proceedings
Design and simulation of a new system for producing laser beams without resonator “NSPLBR”
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Thu Jan 15 2026
Journal Name
Environmental Science And Pollution Research
Laser-assisted neem oil pre-treatment: A novel pathway for high-efficiency biodiesel production
...Show More Authors

Biodiesel is popular as an eco-friendly fossil fuel alternative. Neem oil is manufactured from Azadirachta indica seeds. Transesterifying triglycerides with alcohol in the presence of a synthesized CaO nanocatalyst is the most common biodiesel synthesis procedure—recent advances, difficulties, and prospects in laser feedstock pretreatment to boost reactivity and reduce energy use. Oil pre-treatment with a 540-nm green laser is cost-effective and environmentally friendly. This study examined neem oil with and without laser pretreatment for biodiesel synthesis. CaO nanocatalysts were synthesised using Sol–gel and characterised using XRD and SEM. According to catalyst recyclability, the CaO nanocatalyst did not lose activity after five re

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Apr 01 2026
Journal Name
Desalination And Water Treatment
Performance of a 3D uni-centered iron mesh electrocoagulation–electroflotation reactor for reactive turquoise blue dye removal: Effects of electrode configuration and operating parameters
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Aug 27 2024
Journal Name
Tem Journal
Preparing the Electrical Signal Data of the Heart by Performing Segmentation Based on the Neural Network U-Net
...Show More Authors

Research on the automated extraction of essential data from an electrocardiography (ECG) recording has been a significant topic for a long time. The main focus of digital processing processes is to measure fiducial points that determine the beginning and end of the P, QRS, and T waves based on their waveform properties. The presence of unavoidable noise during ECG data collection and inherent physiological differences among individuals make it challenging to accurately identify these reference points, resulting in suboptimal performance. This is done through several primary stages that rely on the idea of preliminary processing of the ECG electrical signal through a set of steps (preparing raw data and converting them into files tha

... Show More
View Publication
Scopus Clarivate Crossref