Preferred Language
Articles
/
jBZWTogBVTCNdQwCtHa_
Experimental and Numerical Behavior of Encased Pultruded GFRP Beams under Elevated and Ambient Temperatures
...Show More Authors

In this research, experimental and numerical studies were carried out to investigate the performance of encased glass-fiber-reinforced polymer (GFRP) beams under fire. The test specimens were divided into two peer groups to be tested under the effect of ambient and elevated temperatures. The first group was statically tested to investigate the monotonic behavior of the specimens. The second group was exposed to fire loading first and then statically tested to explore the residual behavior of the burned specimens. Adding shear connectors and web stiffeners to the GFRP beam was the main parameter in this investigation. Moreover, service loads were applied to the tested beams during the fire. Utilizing shear connectors, web stiffeners, and both enhanced the load-carrying capacities of the encased beams by 100.6%, 97.3%, and 130.8%, respectively. Comparisons between the burned and unburned peer beams were presented with losses in the load-carrying capacity of the burned beams. These losses were the highest in the cases of shear connectors and web stiffeners due to the obtained severe damage, which led to more reductions in the residual behavior of the burned beams. Numerical analyses were performed using the general-purpose finite element (FE) ABAQUS package to conduct a parametric study. The investigated parameters included the effect of the exposure duration and the temperature level. The results of the FE analysis showed good agreement with the experimental results. Additional reductions in the residual capacities of the fire-damaged beams were observed due to exposure to longer fire durations. The improvements in the beam capacities due to using shear connectors and web stiffeners relative to the reference beams under the same exposure time decreased as the exposure duration increased. Furthermore, increasing the temperature to 700 °C, 800 °C, 900 °C, and 950 °C caused reductions in the residual capacities by about 25%, 45%, 70%, and 80%, respectively, for the encased beams in comparison to their peers at ambient temperature.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Oct 18 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Effect of Purified l-Hydroxyphenazine Pigment on Lymphocytes Viability Against Experimental Secondary Hydatidosis
...Show More Authors

Objectives: To find out the effect of l-hydroxyphenazine (1-HP) on viability of T-lymphocytes and the reflects of this
effect on experimental hyadatidosis on hydatid cyst protoscoleces infectivity in vivo.
Methodology: Four groups of white male /ه/mice were experimentally infected with four concentrations of (1-HP)
with challenge dose of 2000 protoscoleces /1 ml with negative (9.8.5) and positive (P.H.A) control groups.
Results: It has been found that the higher concentrations (75,100) 1101/111 of the (1-HP) causes significant
decrement in the lymphocytes viability in comparison with negative and positive control groups. (060.01).
Recommendations: The study recommended using concentrations lower than 25 pmole Iml which

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
Experimental Evaluation of Evaporative Cooling for Enhancing Photovoltaic Panels Efficiency Using Underground Water
...Show More Authors

This paper presents an experimental study of cooling photovoltaic (PV) panels using evaporative cooling. Underground (geothermal energy) water used to extract heat from it during cooling and cleaning of PV panels. An experimental test rig was constructed and tested under hot and dusty climate conditions in Baghdad. An active cooling system was used with auxiliary an underground water tank to provide cold water as a coolant over both PV surfaces to reduce its temperature. The cellulose pad has been arranged on the back surface and sprays cooling on the front side. Two identical PV panels modules used: without cooling and evaporative water cooling. The experiments are comprised of four cases: Case (I): backside cooling, Ca

... Show More
View Publication Preview PDF
Crossref (13)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Civil Engineering Journal
Calibration of a New Concrete Damage Plasticity Theoretical Model Based on Experimental Parameters
...Show More Authors

The introduction of concrete damage plasticity material models has significantly improved the accuracy with which the concrete structural elements can be predicted in terms of their structural response. Research into this method's accuracy in analyzing complex concrete forms has been limited. A damage model combined with a plasticity model, based on continuum damage mechanics, is recommended for effectively predicting and simulating concrete behaviour. The damage parameters, such as compressive and tensile damages, can be defined to simulate concrete behavior in a damaged-plasticity model accurately. This research aims to propose an analytical model for assessing concrete compressive damage based on stiffness deterioration. The prop

... Show More
Scopus (32)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Sep 15 2020
Journal Name
Arab World English Journal
A Cognitive-Semantic Analysis of Preposition on: An Experimental Study at University of Baghdad
...Show More Authors

View Publication
Crossref (1)
Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Journal Of Engineering
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the

... Show More
View Publication
Publication Date
Sat Jan 01 2022
Journal Name
Thermal Science
Experimental investigation of the thermal performance of wet cooling tower with splash fills packing
...Show More Authors

With the increasing intensity of the ecological and environmental problems and the scarcity of fresh water, this paper was introduced to investigate the ability to use treated wastewater as a cooling media via studying its behavior throughout a cooling tower. The simultaneous transfer of heat and mass from the treated wastewater to air over splash-fill packing arranged in a zigzag manner was studied. The characteristic of the cooling tower, the outlet water temperature, and the rejected heat were investigated as the water-to-air ratio and inlet water temperature were varied. The core results show that the cooling tower of the tower decreases with increasing water-to-air ratio, and increases with the raise of inlet water temperature.

... Show More
View Publication
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Dose-dependent Anti-inflammatory Effect of Silymarin in Experimental Animal Model of Acute Inflammation
...Show More Authors

Silymarin, a flavolignans from seeds of ‘milk thistle’ “Silybum marianum” has been widely used from ancient times because of its excellent hepatoprotective action. It has been used clinically to treat liver disorders including acute and chronic viral hepatitis, toxin/drug-induced hepatitis and cirrhosis and alcoholic liver disease. The efficacy and dose-response effect of silymarin (125, 250 and 500 mg/kg) were assessed using egg albumin-induced paw edema in rats as a model of acute inflammation. In this model, 56 rats were used and allocated into 7 subgroups each containing 8 rats. All treatments were given intraperitonealy 30 minutes before induction of inflammation by egg albumin and then the increase

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 11 2024
Journal Name
International Journal Of Civil Engineering
Strength Evaluation of CFRP-Strengthened RC Slab-Beams System by Load Test to Satisfy the Safety Requirements: A Case Study
...Show More Authors

The primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deter

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Jun 15 2023
Journal Name
Journal Of Population Therapeutics And Clinical Pharmacology
Detection the Phylogenetic groups of E. coli that isolated from diarrheal in children under five years and study their relationship of common serotypes in Baghdad hospitals.
...Show More Authors

Preview PDF