Preferred Language
Articles
/
ixafOogBVTCNdQwCtnXe
Electro-polymerization of poly eugenol on ti and ti alloy dental implant treatment by micro arc oxidation using as anti-corrosion and anti-microbial
...Show More Authors

In this work, electrochemical process was presented to polymerized eugenol on Gr.2 and Gr.5 titanium alloys before and after treated by Micro Arc Oxidation (MAO), where Gr.2 is commercial pure titanium and Gr.5 is Ti-6Al-4V dental alloys. The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of polymeric thin-film was estimation by using pull-off adhesion test and the result was the adhesion strength of PE was (1.23 MPa) on Gr.2 before MAO and increase to (1.98 MPa) on Gr.2 after MAO treatment. The corrosion behavior of Gr.2 and Gr.5 alloy in artificial saliva environment at temperature ranged 293-323K has been studied and assessed by means of electrochemical technique spotentiodynamic polarization curves. The corrosion protection increased to 63% and 80% after coated blank Gr.2 and Gr.5 by PE, while when deposition PE on treated Gr.2 and Gr.5 by MAO, the protection efficiency (I%) increase to 68% and 81% respectively at 323K. The antimicrobial activities of the samples were evaluated against different bacteria and oral fungi (Candia), PE coating show antibacterial activity (28 and 25 mm) against S. aureus and B. Subtilis respectively and show antifungal activity (29 and 24 mm) against C. albicans and C. glabrata oral fungi respectively.

Scopus Crossref
View Publication
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Surface Modification of Ti-6Al-4V Alloy by Glow Discharge-Plasma Nitriding
...Show More Authors

Titanium alloy (Ti-6Al-4V) samples were nitrided in low pressure (1.3, 3 mbar) dc-glow discharge plasmas of nitrogen. The treating time was 5, 10 and 15 hour and the temperatures range of the samples during the nitriding process was close to 800oC. The obtained microstructures of the nitride layers were studied by x-ray diffraction and optical microscopy. The ε –Ti2N, ζ-Ti3N3-x and η-Ti3N2-x.phases were formed and addition to the solid solution of nitrogen in titanium, α (Ti,N). Micro hardness measurements exhibit an increment for the Ti-alloy specimens which nitrided at 800oC for 10 and 15h.Corrosion measurements were obtained for the Ti-6Al-4V alloy in Ringer solution after plasma nitriding. The clear improving in the corrosion r

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Physics And Chemistry Of Solids
Effect of Sr/Mg co-substitution on corrosion resistance properties of hydroxyapatite coated on Ti–6Al–4V dental alloys
...Show More Authors

This study assessed the effect of co-substitution of strontium (Sr) and magnesium (Mg) ions into the hydroxyapatite (HA) coating which was deposited on Ti–6Al–4V dental alloys by an electrochemical deposition process. The deposited layers were examined using energy-dispersive X-ray spectroscopy, scanning electron microscopy, Fourier transform infrared spectroscopy, atomic force microscopy and X-ray diffraction. The corrosion behavior of Ti–6Al–4V alloys in an artificial saliva environment was studied through potentiodynamic polarization technique and electrochemical impedance spectroscopy. The results indicated that the substituted Sr and Mg ions in HA improved the HA coating, where the protection efficiency percentage (PE%) for Ti

... Show More
View Publication
Scopus (14)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Effect of tempering on thermal analysis of Al-Ti-Si alloy and its composites
...Show More Authors

The investigation of the effect of tempering on thermal analysis of
Al-Ti-Si alloy and its composites with MgO and SiC particles was
performed. Thermal analysis was performed before and after
tempering by DSC scan. Optical microscopy was used to identify the
phases and precipitations that may be formed in base alloy and
composites. X-ray diffraction test indicated that the Al3Ti is the main
phase in Al-Ti-Si alloy in addition to form Al5Ti7Si12 phase. Some
chemical reactions can be occurred between reinforcements and
matrix such as MgO.Al2O3 in Al-Ti/MgO, and Al4C3 and Al(OH)3 in
Al-Ti/SiC composite. X-ray florescence technique is used to
investigate the chemical composition of the fabricated specimens.
H

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of adding titanium dioxide nanoparticles on anti-microbial activity and surface detail reproduction of dental alginate
...Show More Authors

Most dental works require a diagnostic impression; alginate is contemplated as the most popular material used for this purpose. Titanium dioxide nanoparticles show evidence of antimicrobial activity in the recent era, for this purpose, this study aimed to evaluate the effect of adding Titanium dioxide nanoparticles on antimicrobial activity and surface detail reproduction of alginate impression material. Materials and methods: Titanium dioxide nanoparticles (purity = 99%, size= 20nm) was added to alginate at three different concentrations (2%, 3% and 5%). 84 samples were prepared in total. Samples were tested for antimicrobial activity using a disc diffusion test, and surface detail reproduction was done using (ISO 21563:2021). One-way A

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (4)
Scopus Crossref
Publication Date
Sun Jun 26 2022
Journal Name
International Journal Of Corrosion And Scale Inhibition
Synthesis of polysulfanilamide by electro polymerization and its corrosion protective properties on 316L stainless steel in 0.2 M HCl
...Show More Authors

The electrochemical polymerization of the monomer sulfanilamide (SAM) in an aqueous solution at room temperature produces polysulfanilamide (PSAM). The Fourier Transform Infrared spectroscopy (FTIR) was used to investigate the properties of the prepared polymer layer that generated on the stainless steel (St.S) surface (working electrode) and Atomic Force Microscope (AFM) was used to characterize the morphology, topology, and detailed surface structure of polymer layer that generated on the surface. The corrosion behavior of uncoated and coated St.S were evaluated by using the electrochemical polarization method in a 0.2 M HCl solution and a temperature range of 293–323 K, the anticorrosion action of the polymer coating on stainless steel

... Show More
View Publication
Scopus (4)
Scopus Clarivate Crossref
Publication Date
Sat Nov 04 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and Preliminary Anti-Inflammatory and Anti-Microbial Evaluation of New 4,5-Dihydro-1H-Pyrazole Derivatives
...Show More Authors

Abstract      Organic compounds with pyrazole cores have a variety of uses, notably in the pharmaceutical and agrochemical sectors. The interest in creating pyrazole compounds, examining their many features, and looking for potential uses is growing. Our work has concert with synthesis of  chalcones and pyrazolines, then finally pyrazoline-aniline derivatives and evaluation their anti-inflammatory, antibacterial and antifungal activities

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Sep 14 2021
Journal Name
Egyptian Journal Of Chemistry
Real wastewater Treatment by Electrocoagulation- Electro-oxidation Combined System: Optimization using Taguchi Approach
...Show More Authors

In this study, the optimum conditions for COD removal from petroleum refinery wastewater by using a combined electrocoagulation- electro-oxidation system were attained by Taguchi method. An orthogonal array experimental design (L18) which is of four controllable parameters including NaCl concentration, C.D. (current density), PH, and time (time of electrolysis) was employed. Chemical oxygen demand (COD) removal percentage was considered as the quality characteristics to be enhanced. Also, the value of turbidity and TDS (total dissolved solid) were estimated. The optimum levels of the studied parameters were determined precisely by implementing S/N analysis and analysis of variance (ANOVA). The optimum conditions were found to be NaCl = 2.5

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Effect of Sn Addition on Phase Transformation Behavior of Equiatomic Ni-Ti Shape Memory Alloy
...Show More Authors

Sn effect on the phase transformation behavior, microstructure, and micro hardness of equiatomic Ni-Ti shape memory alloy was studied. NiTi and NiTiSn alloys were produced using vacuum induction melting process with alloys composition (50% at. Ni, 50% at.Ti) and (Ni 48% at., Ti 50% at., Sn 2% at.). The characteristics of both alloys were investigated by utilizing Differential Scanning Calorimetry, X- ray Diffraction Analysis, Scanning Electron Microscope, optical microscope and vicker's micro hardness test. The results showed that adding Sn element leads to decrease the phase transformation temperatures evidently. Both alloy samples contain NiTi matrix phase and Ti2Ni secondary phase, but the Ti2Ni phase content dec

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri Jun 01 2018
Journal Name
Current Medical Science
Biomechanical Evaluation of Nano-Zirconia Coatings on Ti-6Al-7Nb Implant Screws in Rabbit Tibias
...Show More Authors

View Publication
Crossref (16)
Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Surface assessment of CNC laser treated commercially pure Titanium and Ti 13 Zr 13 Nb alloy
...Show More Authors

This study aimed to evaluate the surface changes of commercial pure Titanium disks (CP Ti) and the Ti 13Nb 13 Zr (Alloy) with a zigzag pattern of laser surface treatment. In vitro, experimental study of CNC Laser treatment on the CP Ti and Alloy disks. Texturing the surfaces of CP Ti and Alloy disks via CNC laser, the sample disks were analyzed using surface roughness, wettability and FESEM. The FESEM revealed a proper increase in the surface texturing and roughness on macro and micro measures without crack formation or dramatic change of the core substance of the CP Ti and Alloy disks. The CNC laser is an effective and suitable method for surface texturing CP Ti and Alloy for dental implantology. Keywords: Commercial pure Titanium;

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref