Background: The axillary artery is a direct continuation of the subclavian artery. The axillary artery is usually described as giving off six branches. The first part gives superior thoracic artery. The second part gives lateral thoracic (LT) and thoracoacromial(TAC) arteries. The third part gives three, subscapular(SS), anterior circumflex humeral(ACH)and posterior circumflex humeral(PCH) arteries. Anatomical variations in the branching pattern of axillary artery are quiet common and typically include the subscapular artery(SS), lateral thoracic artery(LT) and the posterior circumflex humeral artery(PCH). The variation of the axillary artery branching pattern has anatomical as well as clinical and surgical relevance given the proximity to the shoulder joint and humerus.
Patients & Method: Bilateral axilla dissection was conducted on 26 embalmed axillae (13 cadavers) to allow examination of the axillary artery and its branches. The study was carried out in Department of Human Anatomy, College of Medicine.
Results: The classical branching pattern of the LT originating from the axillary artery posterior to the pectoralis minor muscle and the SS producing the circumflex scapular (CS) artery and thoracodorsal(TD) occurred in 77%. The SS was observed originating from the LT 7% of the time. The LT was observed originating from the SS 5% of the time. The LT was observed producing the circumflex scapular artery and TD in the absence of SS 2.5% of the time. The PCH originated from four different sources, from the third part of axillary artery as is classically described in 77%. From the SS 11%. From deep brachial artery DB 9% and from LT 2%.
Conclusion: Vascular variation in the axillary artery and its branches is quiet common , This variation should be considered seriously as will implicate risk of bleeding during surgery in the axilla and also the difficulty in interpretation of the angiography after axillary catheterization.
An observational study to discover the common conditions affecting the lumbosacral region that may affect lumbosacral position and tension. All the patients, underwent MRI exaamination (magnetic resonance imaging) in the supine position, were examined by the same consultant radiologist. The article was revised by the institutional ethical approval committee. The position of the nerve roots was observed, and the number of nerve roots was calculated anterior to a line passing between the mid-transvers process of L3(third lumbar vertebra). The number of nerve roots ahead of this line was calculated by the radiologist at the level of the right intervertebral foramen and at the left one. This procedure was applied to the normal group, an
... Show MoreBackground: Clinical classification of patients with acute coronary syndrome is essential step in identifying severe cases before referring them, fairly quickly, for the ultimate investigation of coronary angiography .Hence it is important to find out the extent at which the severity of the disease, based on clinical classification, agrees with its severity at angiography and to see whether traditional Risk factors or pas ischaemia played a role.
Patients and Methods : The angiographer data of 178 consecutive pts with Acute Coronary Syndrome (ACS) were retrospectively analyzed. The pts consisted of 114 with Unstable Angina (UA) and 64 pts with Non-ST-Segment Elevation Myocardial Infarction (NSTEMI). Pati
Background: Diabetes and hypertension are related to cardiovascular risk factors and are possible to detect development of atherosclerosis in cardiovascular system, were can predict their effect and measurement by ultrasound and Doppler study. These risk factors included increased intima-media thickness, resistive index (RI) and pulsatility index (PI) of the right common carotid arteries. Method: We studied 20 patients with diabetes and hypertension, and 20 patients with diabetes only, were examine right carotid arteries for these two groups. In this sample we studied the Lumen diameter of the Rt. carotid arteries, Intima – media thickness (IMT), peak systolic velocity, end diastolic velocity, and Pulsatility index, Resistance index were
... Show MoreThe Normalized Difference Vegetation Index (NDVI) is commonly used as a measure of land surface greenness based on the assumption that NDVI value is positively proportional to the amount of green vegetation in an image pixel area. The Normalized Difference Vegetation Index data set of Landsat based on the remote sensing information is used to estimate the area of plant cover in region west of Baghdad during 1990-2001. The results show that in the period of 1990 and 2001 the plant area in region of Baghdad increased from (44760.25) hectare to (75410.67) hectare. The vegetation area increased during the period 1990-2001, and decreases the exposed area.
Background: Sex variations in coronary artery disease (CAD) are well documented. However, sex differences in coronary artery calcium (CAC) and its role in the detection of coronary artery stenosis remain controversial. Objective: To assess the impact of sex variation on coronary artery calcification and its efficacy in predicting coronary artery stenosis. Methods: This is a cross-sectional observational study including 230 consecutive patients with suspected CAD (120 men and 110 women) referred for coronary computed tomography angiography (CCTA). The study analyzed sex-based differences in the sensitivity and specificity of coronary artery calcification (CAC) for detecting moderate to severe stenosis across various coronary arteries
... Show MoreBackground: Arterial stiffness is related with atherosclerosis and cardiovascular disease events. Patients with atherosclerotic disease show to have larger diameters, reduced arterial compliance and lower flow velocities. Aim of study : To compare between patients of two age groups with concomitant diseases diabetes and hypertension in regard to intima media thickness and blood flow characteristics in order to estimate the blood perfusion to the brain via the common and internal carotid arteries. Subject and Methods : 40 patients with (diabetic and hypertension) diseases were enrolled , they were classified according to age. Color Doppler and B mode ultrasound was used to determine lumen Diameter (D), Intima – media thickness (IMT)
... Show MoreAccurate description of thermodynamic, structural, and electronic properties for bulk and surfaces of ceria (CeO2) necessitates the inclusion of the Hubbard parameter (U) in the density functional theory (DFT) calculations to precisely account for the strongly correlated 4f electrons. Such treatment is a daunting task when attempting to draw a potential energy surface for CeO2-catalyzed reaction. This is due to the inconsistent change in thermo-kinetics parameters of the reaction in reference to the variation in the U values. As an illustrative example, we investigate herein the discrepancy in activation and reaction energies for steps underlying the partial and full hydrogenation of acetyl
... Show MoreThe seasonal variation of two groups of Zooplankton were studied in Diyala river and two branches , about 30Km from Diyala dam It was found that there are differences in the distribution of the two groups . Atotal of six species were identified of Copepoda in Diyala river and its two branches . The species are Cyclops vernalis . C . visinus , C . dimorphus , Mesocyclops laukartu ,Paracyclops affinis and Diaptomus reighardi , where recorded high annual density in Khalis stream . Its annual density was between 0.55 – 20.66 Ind . / L. Wheras, Cladocera group 14 species were identified . and the most disturbance spe
... Show MoreIn this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.