Background: Multiple sclerosis (MS) is a chronic, demyelinating disease of the central nervous system (CNS) affecting young adults and is considered as the leading cause of non traumatic neurological disability of young adults affecting nearly 2 million people worldwide. The pathogenesis of MS is at best incompletely understood. There are several proposed mechanisms that may be important in the production of MS plaques: autoimmunity, environment and heredity. Deviation of immune responses in a genetically susceptible patient plays a central role in its pathogenesis. Electrophysiological, spinal tap and Radiological tools are important laboratory investigations and have added so much to the clinical diagnosis and for the classification of MS. It was found that visual function and conduction has been changed in patients with multiple sclerosis.
Objectives: The aims of the study is to estimate and evaluate the visual evoked potential (VEP) parameters in patients with MS and its relation to their disability degree (using the expanded disability status scale score "EDSS") and visual presentation of them in comparison with healthy individuals.
Patients and Methods: 112 patients with multiple sclerosis and 50 subjects without any neurological or psychiatric diseases as control group were recruited in this study. The cases were collected from Baghdad teaching hospital, MS center, Baghdad, Iraq at the period from May 2012 to April 2013, and studied at the unit of electrophysiology in Al-Shaheed Ghazi Al-Hareri Hospital in the Medical city. All patients and control groups were tested for VEP.
Results: The present study showed a significant increase in the P100 latency and inter-ocular (IO) latency difference and non statistical significant decrease in the IO amplitude difference in patients group than the control group. Also among patients group there was positive linear correlation between the severity of the disease measured by EDSS score and P100 latency while negative linear correlation with the amplitude.
Conclusion: There was a higher percent of patients with defective VEP parameters and so their visual pathway even if it was asymptomatic, in addition to their relation with patients` disability than the control group, making it easy to quantify and predict MS disability objectively.
Keywords: Multiple sclerosis, Expanded Disability Status Scale, VEP.
Some physical properties enthalpy (?H), entropy (?s), free energy (?G),capacities(?cp?) and Pka values) for valine in dimethyl foramideover the temperature range 293.15-318.15K, were determined by direct conductance measurements. The acid dissociation at six temperature was examined at solvent composition x2) involving 0.141 of dimethyl foramide . As results, calculated values have been used to determine the dissociation constant and the associated thermodynamic function for the valine in the solvent mixture over temperatures in the range 293.15-318.15 k. The Pka1, and Pka2 were increased with increasing temperature.
Under-reamed piles defined by having one or more bulbs have the potential for sizeable major sides over conventional straight-sided piles, most of the studies on under-reamed piles have been conducted on the experimental side, while theoretical studies, such as the finite element method, have been mainly confined to conventional straight-sided piles. On the other hand, although several laboratory and experimental studies have been conducted to study the behavior of under-reamed piles, few numerical studies have been carried out to simulate the piles' performance. In addition, there is no research to compare and evaluate the behavior of these piles under dynamic loading. Therefore, this study aimed to numerically investigate bearing capaci
... Show MoreTo date, comprehensive reviews and discussions of the strengths and limitations of Remote Sensing (RS) standalone and combination approaches, and Deep Learning (DL)-based RS datasets in archaeology have been limited. The objective of this paper is, therefore, to review and critically discuss existing studies that have applied these advanced approaches in archaeology, with a specific focus on digital preservation and object detection. RS standalone approaches including range-based and image-based modelling (e.g., laser scanning and SfM photogrammetry) have several disadvantages in terms of spatial resolution, penetrations, textures, colours, and accuracy. These limitations have led some archaeological studies to fuse/integrate multip
... Show MoreUnder-reamed piles are piles with enlarged bases, which may be single bulb or multi bulbs. Such piles are suitable for resisting considerable soil movement of filed up ground, soft clay, and loose sand and have the advantages of increasing the soil strength and decreasing the displacement. In the present study, the finite element method was used to analyse the performance of a single pile with under-reamed bulbs of different shapes, that is, single cone, double cone, and half and full sphere, embedded in homogeneous, poorly graded sandy soil. The model of under-reamed pile was made of reinforced concrete and the bulb located at the middle of the embedded length of the pile. The dynami
In the present study, advanced oxidation treatment, the TiO2 /UV/H2O2 process was applied to decolorisation of the reactive yellow dyes in aqueous solution. The UV radiation was carried out with a 6 W low-pressure mercury lamp. The rate of color removal was studied by measuring the absorbency at a characteristic wavelength. The effects of H2O2 dosage, dye initial concentration and pH on decolorisation kinetics in the batch photoreactor were investigated. The highest decolorisation rates were observed (98.8) at pH range between 3 and 7. The optimal levels of H2O2 needed for the process were examined. It appears that high levels of H2O2 could reduce decolori
... Show MoreMefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen
... Show More