Background: Multiple sclerosis (MS) is a chronic, demyelinating disease of the central nervous system (CNS) affecting young adults and is considered as the leading cause of non traumatic neurological disability of young adults affecting nearly 2 million people worldwide. The pathogenesis of MS is at best incompletely understood. There are several proposed mechanisms that may be important in the production of MS plaques: autoimmunity, environment and heredity. Deviation of immune responses in a genetically susceptible patient plays a central role in its pathogenesis. Electrophysiological, spinal tap and Radiological tools are important laboratory investigations and have added so much to the clinical diagnosis and for the classification of MS. It was found that visual function and conduction has been changed in patients with multiple sclerosis.
Objectives: The aims of the study is to estimate and evaluate the visual evoked potential (VEP) parameters in patients with MS and its relation to their disability degree (using the expanded disability status scale score "EDSS") and visual presentation of them in comparison with healthy individuals.
Patients and Methods: 112 patients with multiple sclerosis and 50 subjects without any neurological or psychiatric diseases as control group were recruited in this study. The cases were collected from Baghdad teaching hospital, MS center, Baghdad, Iraq at the period from May 2012 to April 2013, and studied at the unit of electrophysiology in Al-Shaheed Ghazi Al-Hareri Hospital in the Medical city. All patients and control groups were tested for VEP.
Results: The present study showed a significant increase in the P100 latency and inter-ocular (IO) latency difference and non statistical significant decrease in the IO amplitude difference in patients group than the control group. Also among patients group there was positive linear correlation between the severity of the disease measured by EDSS score and P100 latency while negative linear correlation with the amplitude.
Conclusion: There was a higher percent of patients with defective VEP parameters and so their visual pathway even if it was asymptomatic, in addition to their relation with patients` disability than the control group, making it easy to quantify and predict MS disability objectively.
Keywords: Multiple sclerosis, Expanded Disability Status Scale, VEP.
This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis
... Show MoreThis study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis of variance (ANO
... Show MoreLaboratory studies were conducted at the biological control unit, college of Agriculture, University of Baghdad to evaluate some biological aspects of the predator Chilocorus bipustulatus (Coleoptera: Coccinellidae), which is considered one of the most important predators on many insect pests, especially the scale insect, Parlatoria blanchardi, (Homoptera: Diaspididae) on date palms. The results showed that biological parameters of the predator were varied according to different degree of temperature. Egg incubation period was significantly different and reached to 7.5 and 5.44 day at 25 and 30°C respectively, Fertility was the same 100% at both temperature degrees. Larval growth periods were 17.41 and 16.12 day as well as the mortality du
... Show Moreالوصف A simple chemistry method approach was used to synthesise new ligand derivate from L-ascorbic acid and its complexes. All of them were water-soluble and are used quite extensively in the medical and pharmaceutical fields. This study synthesised the new ligand derivative from L-ascorbic acid-base using the following steps: A 5, 6-O-isopropylidene-L-ascorbic acid was prepared by reacting dry acetone with L-ascorbic acid followed by reacting it with trichloroacetic acid to yield [chloro (carboxylic) methylidene]-5, 6-O-isopropylidene-L-ascorbic acid in the second stage. In the third stage, the derivative was reacted with (methyl (6-methyl-2-pyridylmethyl) amine to create a new ligand (ONMILA). This novel ligand was identified using
... Show MoreThe [2-hydroxy-1, 2-diphynel-ethanone oxime] was reacted with 1, 2-dichloroethan to give the new ligand [H2L]. this ligand was reacted with some metal ions (Co (II), Ni (II), Cu (II), Zn (II) and Cd (II) in methanol as a solvent to give a series of new (1: 1) complexes of the general formula [M (HL)] Cl,(where: M= Co (II), Ni (II), Cu (II), Zn (II) and Cd (II)) are isolated All compounds have been characterized by spectroscopic methods [IR, UV-Vis] atomic absorption. Chloride content along with conductivity measurements. From the above data the proposed molecular structure for (Co, Cu, Ni, Zn and Cd) complexes adopting a tetrahedral structure
Infrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector
... Show MoreErratum for Organic acid concentration thresholds for ageing of carbonate minerals: Implications for CO2 trapping/storage.