Preferred Language
Articles
/
iqjmc-889
Comparison between Mammography and Breast Ultrasound in the Detection of Breast Cancer in Dense Breast Tissue among a Sample of Iraqi Women
...Show More Authors
Background: Breast cancer is the most common cancer reported in women worldwide . In Iraq, it is the  most common registered malignancy. Mammography plays a major role in  the early detection of breast cancers. Dense breast parenchyma has been reported to be the most important inherent factor that limits  depiction of breast cancer on mammogram, and often needs supplementary breast ultrasound for complete assessment. 
Objectives: To evaluate and compare the diagnostic performance of mammography and ultrasound in the
detection of breast cancer in dense breast tissue.
Patients and methods: A record review study was performed in the Oncology Teaching Hospital/ Medical
City from April 2018 to December 2018. The study included forty five females, who attended the Main
Referral Center for Early Detection of Breast Tumors during 2017 and 2018 were diagnosed with breast  cancer histopathologically . They had dense breast tissues on mammography (either heterogeneously dense
breast tissue i.e . category C or extremely dense breast tissue i.e. category D). All patients underwent  subsequent breast ultrasound . Their information including the mammogram findings, breast ultrasound,
fine needle aspiration (FNA) and biopsy results were reviewed analyzed and compared.
Results:Twenty four patients (53.3%) had heterogeneously dense breast tissue (ACR category C) and 21
patients (46.6%) had extremely dense breast tissue (ACR category D). The mammogram detected 36 from 45
breast cancers (80%) while 9 (20%) were not detected by mammogram, so the mammogram had a detection
rate of breast cancer of 80% in mammographically dense breast, while breast ultrasound had higher  detection rate of about 97.7% .The sensitivity of mammography in extremely dense breast tissue was about 71% and in heterogeneously dense breast was about 87% while ultrasound had shown a higher sensitivity
with increasing tissue density (98% vs. 100%).
Conclusion: Breast cancer can be easily obscured and missed in mammographically dense breast tissue due
to overlapping surrounding fibroglandular tissue and additional complementary breast ultrasound is highly
recommended for a thorough evaluation and to depict mammographically occult breast carcinoma.
Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Feb 25 2024
Journal Name
Baghdad Science Journal
Prioritized Text Detergent: Comparing Two Judgment Scales of Analytic Hierarchy Process on Prioritizing Pre-Processing Techniques on Social Media Sentiment Analysis
...Show More Authors

Most companies use social media data for business. Sentiment analysis automatically gathers analyses and summarizes this type of data. Managing unstructured social media data is difficult. Noisy data is a challenge to sentiment analysis. Since over 50% of the sentiment analysis process is data pre-processing, processing big social media data is challenging too. If pre-processing is carried out correctly, data accuracy may improve. Also, sentiment analysis workflow is highly dependent. Because no pre-processing technique works well in all situations or with all data sources, choosing the most important ones is crucial. Prioritization is an excellent technique for choosing the most important ones. As one of many Multi-Criteria Decision Mak

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Food And Nutrition Sciences
Optimization of Culture Conditions to Produce Phytase from <i>Aspergillus tubingensis SKA</i>
...Show More Authors

The effects of nutrients and physical conditions on phytase production were investigated with a recently isolated strain of Aspergillus tubingensis SKA under solid state fermentation on wheat bran. The nutrient factors investigated included carbon source, nitrogen source, phosphate source and concentration, metal ions (salts) and the physical parameters investigated included inoculum size, pH, temperature and fermentation duration. Our investigations revealed that optimal productivity of phytase was achieved using wheat bran supplemented with: 1.5% glucose. 0.5% (NH4)2SO4, 0.1% sodium phytate. Additionally, optimal physical conditions were 1 × 105 spore/g substrate, initial pH of 5.0, temperature of fermentation 30˚C and fermentation dura

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
REMOVAL OF PHENOLIC COMPUNDS FROM AQUEOUS SOLUTIONS BY ADSOPTION ONTO ACTIVTED CARBONS PREPARED FROM DATE STONES BY CHEMICAL ACTIVATION WITH FeCl3
...Show More Authors

Activated carbon prepared from date stones by chemical activation with ferric chloride (FAC) was used an adsorbent to remove phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) from aqueous solutions. The influence of process variables represented by solution pH value (2-12), adsorbent to adsorbate weight ratio (0.2-1.8), and contact time (30-150 min) on removal percentage and adsorbed amount of Ph and PNPh onto FAC was studied. For PNPh adsorption,( 97.43 %) maximum removal percentage and (48.71 mg/g) adsorbed amount was achieved at (5) solution pH,( 1) adsorbent to adsorbate weight ratio, and (90 min) contact time. While for Ph adsorption, at (4) solution pH, (1.4) absorbent to adsorbate weight ratio, and (120 min) contact

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Nov 04 2021
Journal Name
Optik - International Journal For Light And Electron Optics
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355 nm for sensing NH3 gas
...Show More Authors

The current study aimed the syntheses and characterizations of Gold nanoparticles (Au NPs) using a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the

... Show More
Publication Date
Sun Oct 06 1996
Journal Name
Iraqi Journal Of Chemistry
Synthesis of new Schiff bases derived from [3-amino-3-C-cyano-3-deoxy-1,2:5,6-di-O-isopropylidene-Ξ±-D-allofuranose
...Show More Authors

Aromatic Schiff-bases are known to have antibacterial activity, but most of these compounds are sparingly soluble in water. The present work describes the synthesis of new Schiff-bases derived from branched aminosugars. Treatment of 3-Amino-3-Cyano-3-Deoxy-1,2:5,6-Di-O-Isopropylene-α-D-Allofuranose (1) with the aldehydes (2) under reflux in methanol afforded the Schiff-bases (3) in good yields. The new Schiff-bases were in accord with their NMR, IR spectral data and elemental analysis.

Preview PDF
Publication Date
Thu Aug 01 2019
Journal Name
International Journal Of Research - Granthaalayah
MULTIPLE MIXING RATIOS OF GAMMA RAY TRANSITIONS FROM πŸ”πŸŽππ πŸπŸ’πŸβˆ’ πŸπŸ“πŸŽ (𝐧, 𝐧 ΛŠπ›„) πŸ”πŸŽππ πŸπŸ’πŸβˆ’ πŸπŸ“πŸŽ REACTION USING π’‚πŸ- RATIO METHOD
...Show More Authors

In the current work, the mixing ratios ( 𝛿 ) of gamma transitions were calculated from energy levels in the isotopes neodymium 60𝑁𝑎 142−150 populated in the 60Nd 142− 150 (n, n ˊγ) 60Nd 142− 150 using the 𝑎2 ratio method. We used the experimental coefficient (𝑎2 ) for two γ-transitions from the initial state itself, the statistical tensor 𝜌2(𝐽𝑖), associated with factor 𝑎2 , would be the same for the two transitions. The results obtained are in good agreement or within the experimental error with -those previously published. And existing contradictions resulting from inaccuracies in the empirical results of previous work. The current results confirm that the , 𝑎2 − method is used to calculate th

... Show More
Publication Date
Sat Jan 01 2022
Journal Name
Optik
Plasma parameters of Au nano-particles ablated on porous silicon produced via Nd-YAG laser at 355Β nm for sensing NH3 gas
...Show More Authors

a laser ablation Q-switched Nd: YAG laser with a wave-length of 355 nm at a variety of laser pulse energies (E) and deposited on porous silicon (PS). Optical emission spectrometer was used to diagnosed medium air to study gold plasma characteristics and prepared Au nanoparticles. The laser pulse energy influence has been studied on the plasma characteristics in air. The data showed the emergence of the ionic (Au II) spectral emission lines in the gold plasma emission spectrum. XRD has been utilized to examine structural characteristics. Moreover, AFM results 37.2 nm as the mean value of the diameter that is coordinated in a shape similar to the rod that appears for Au NPs, in addition to that, TEM has been an indication of the fact that syn

... Show More
View Publication
Scopus (32)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Tue Sep 08 2020
Journal Name
Baghdad Science Journal
Improved throughput of Elliptic Curve Digital Signature Algorithm (ECDSA) processor implementation over Koblitz curve k-163 on Field Programmable Gate Array (FPGA)
...Show More Authors

            The widespread use of the Internet of things (IoT) in different aspects of an individual’s life like banking, wireless intelligent devices and smartphones has led to new security and performance challenges under restricted resources. The Elliptic Curve Digital Signature Algorithm (ECDSA) is the most suitable choice for the environments due to the smaller size of the encryption key and changeable security related parameters. However, major performance metrics such as area, power, latency and throughput are still customisable and based on the design requirements of the device.

The present paper puts forward an enhancement for the throughput performance metric by p

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Nov 28 2020
Journal Name
Iraqi Journal Of Science
Electrochemical Deposition of Hydroxyapatite Co-Substituted By Sr/Mg Coating on Ti-6Al-4V ELI Dental Alloy Post-MAO as Anti-Corrosion
...Show More Authors

This work involved the co-substitution of the two bioactive ions of strontium and magnesium into the hydroxyapatite (HA) coating which was then electrochemically deposited on Ti-6Al-4V ELI dental alloy (Gr.23) before and after treatment by Micro Arc Oxidation (MAO). The deposited layers were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The adhesion strength of the coating layer was estimated by using pull-off adhesion test. The adhesion strength of Sr/Mg-HA on the Ti-6Al-4V ELI dental alloy after MAO treatment was 1.79 MPa, which was higher than that before MAO treatment (1.62 MPa). The corrosion behavior of th

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (3)
Scopus Crossref
Publication Date
Thu May 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Multipole Mixing Ratios of Gamma Rays From Fe(n,nγ) Fe 56 56 26 26 Γ―β€šΒ’ Reaction Using Constant Statistical Tensor Method (CST).
...Show More Authors

The - Multiple mixing ratios of -transitions from levels of 56Fe populated in 56 56 ( , ) Fe n n Fe  ï‚¢ reactions are calculated by using const. S.T.M.  This method has been used in other works [3,7] but with pure transition or with  transitions that can be considered as pure transitionsØŒ in our work we used   This method for mixed  - transitions in addition to pure  - transitions. The experimental angular distribution coefficients a2 was used from previous works [1] in order to calculet - values. It is clear from the results that the - values are in good agreement or consistent, within associated errors, with those reported previously [1]. The discrepancies that occur

... Show More
View Publication Preview PDF