Background: The role of Human papillomaviruses (HPV) in the etiology of ovarian cancer remains unclear and the results are controversial. Several studies have verified the presence of HPV DNA in both malignant and benign ovarian tumors.
Objectives: Determine the percentage of detection of HPV high (16&18) and low risk types (6&11) in surface epithelial ovarian carcinoma compared to benign and control groups.
Materials And Methods: Molecular detection and genotyping of HPV DNA were performed in 76 ovarian tissue blocks by using in situ hybridization (ISH) technique for detecting and localization of high risk HPV (16 and 18) and low risk HPV (6&11) types.
Results: The presence of ISH signals for HPV DNA in benign group (71%) was higher than that found in malignant group (64%). HPV 16 was the most predominant type followed by HPV18, 6, and 11 respectively in both malignant and benign groups. High risk HPV were presented with low score and high intensity in both malignant and benign tumors. Low risk HPV types were detected in high score and intensity in benign tumors which significantly differed from that with malignant tumors, which revealed low score and low intensity. The percentage of co-infection of low risk HPV6&11 in benign group was higher (16.9%) than malignant group (7.1%). Only significant difference was found in combination of both high and low risk HPV types.
Conclusions: This finding reflects a possible role of HPV virus in the carcinogenesis of ovarian tumors. HPV infection may play a relative role in the pathogenesis of ovarian carcinomas or it could facilitate its progression.
Background: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreObjectives The strategies of tissue-engineering led to the development of living cell-based therapies to repair lost or damaged tissues, including periodontal ligament and to construct biohybrid implant. This work aimed to isolate human periodontal ligament stem cells (hPDLSCs) and implant them on fabricated polycaprolactone (PCL) for the regeneration of natural periodontal ligament (PDL) tissues. Methods hPDLSCs were harvested from extracted human premolars, cultured, and expanded to obtain PDL cells. A PDL-specific marker (periostin) was detected using an immunofluorescent assay. Electrospinning was applied to fabricate PCL at three concentrations (13%, 16%, and 20% weight/volume) in two forms, which were examined through field emission
... Show MoreIn this paper a new structure for the AVR of the power system exciter is proposed and designed using digital-based LQR. With two weighting matrices R and Q, this method produces an optimal regulator that is used to generate the feedback control law. These matrices are called state and control weighting matrices and are used to balance between the relative importance of the input and the states in the cost function that is being optimized. A sample power system composed of single machine connected to an infinite- bus bar (SMIB) with both a conventional and a proposed Digital AVR (DAVR) is simulated. Evaluation results show that the DAVR damps well the oscillations of the terminal voltage and presents a faster respo
... Show MoreBackground: Radiopacity is one of the prerequisites for dental materials, especially for composite restorations. It's essential for easy detection of secondary dental caries as well as observation of the radiographic interface between the materials and tooth structure. The aim of this study to assess the difference in radiopacity of different resin composites using a digital x-ray system. Materials and methods: Ten specimens (6mm diameter and 1mm thickness) of three types of composite resins (Evetric, Estelite Sigma Quick,and G-aenial) were fabricated using Teflon mold. The radiopacity was assessed using dental radiography equipment in combination with a phosphor plate digital system and a grey scale value aluminum step wedge with thickness
... Show MoreIn this paper, suggested formula as well a conventional method for estimating the twoparameters (shape and scale) of the Generalized Rayleigh Distribution was proposed. For different sample sizes (small, medium, and large) and assumed several contrasts for the two parameters a percentile estimator was been used. Mean Square Error was implemented as an indicator of performance and comparisons of the performance have been carried out through data analysis and computer simulation between the suggested formulas versus the studied formula according to the applied indicator. It was observed from the results that the suggested method which was performed for the first time (as far as we know), had highly advantage than t
... Show MoreIn this research a computational simulation has been carried out on the design and properties of the electrostatic mirror and a mathematical expression has been suggested to represent the axial potential of an electrostatic mirror. The electron beam path using the Bimurzaev technique had been investigated as mirror trajectory with the aid of Runge – Kutta method. The spherical and chromatic aberration coefficients of mirror has computed and normalized in terms of the focal length. The choice of the mirror depends on the operational requirements. The Electrode shape of mirror two electrodes has been determined by using package SIMION computer program. Computations have shown that the suggested potentials giv
... Show MoreIn this work, copper substituted cobalt ferrite nanoparticles with
chemical formula Co1-xCuxFe2O4 (x=0, 0.3, and 0.7), has been
synthesized via hydrothermal preparation method. The structure of
the prepared materials was characterized by X-ray diffraction (XRD).
The (XRD) patterns showed single phase spinel ferrite structure.
Average crystallite size (D), lattice constant (a), and crystal density
(dx) have been calculated from the most intense peak (311).
Comparative standardization also performed using smaller average
particle size (D) on the XRD patterns of as-prepared ferrite samples
in order to select most convenient hydrothermal synthesis conditions
to get ferrite materials with smallest average particl
Bilinear interpolation and use of perceptual color spaces (HSL, HSV, LAB, and LUV) fusion techniques are presented to improve spatial and spectral characteristics of the multispectral image that has a low resolution to match the high spatial resolution of a panchromatic image for different satellites image data (Orbview-3 and Landsat-7) for the same region. The Signal-to-Noise Ratio (SNR) fidelity criterion for achromatic information has been calculated, as well as the mean color-shifting parameters that computed the ratio of chromatic information loss of the RGB compound inside each pixel to evaluate the quality of the fused images. The results showed the superiority of HSL color space to fuse images over the rest of the spac
... Show MoreThis study has investigated the effect of jaundice on some
hematological and biochemical paramenters in male and female. The results have shown significant decrease in Hemoglobin concentration, packed cell volume, white blood cell count and platelet count. The biochemical parameters results have shown significant increase in prothrombine time, level of total bilirubin, Aspartale transminase and Alanin trans aminase in the serum of male and femal.
The main rationale for using charged particles in radiation therapy is the strong rise of energy loss (deposited dose) with maximum penetration depth ( Bragg peak) and rapid dose deposited behind the peak. Thus, a large dose can be applied to a deep seated tumor, with saving the surrounding normal tissues . Proton radiotherapy is nowadays an established method in the management of cancer diseases, although its availability is still limited to a few specialized centers. In this study, the range and the stopping power for proton interaction in the skeleton and intestine tissues, for an energy range from 0.01 to 300 MeV, was studied. The numerical calculations and analyses of Bethe&nbs
... Show More