Background: Carpal tunnel syndrome (CTS) is one of common peripheral nerve disorder which involves an entrapment neuropathy of the median nerve at the wrist which occurs either due to primary idiopathic cause or secondary to systemic causes. The diagnosis of CTS is clinical and supported by neurophysiological analysis. Surgical intervention is the main treatment modality.
Objective: The aim of the present study is to evaluate the effectiveness of low level laser therapy (LLLT) to treat mild – moderate CTS cases.
Pateients and methods: The study involves 60 symptomatic patients complaining of CTS were divided into two groups. Group A was subjected to real LLLT by Gallium – Arsenide (Ga-As) laser (904 nm), whereas group B was subjected to sham laser. Thirty asymptomatic normal individuals as group C were subjected to real LLLT in the same protocol as that applied to CTS cases. The individuals were evaluated clinically and by nerve conduction studies (NCSs) at early time as baseline reading and immediately after the treatment and later on after two weeks from stopping the treatment sessions.
Results: LLLT showed significant pain reduction (70.9%) and improved latency and amplitude studies for sensory (16.7% and 29%, respectively) and motor (18% and 26%, respectively) median nerve fibers in patients group who were exposed to real laser therapy in comparison to sham group but normal individuals showed significant increment in motor amplitude (12%) after completing therapy sessions. Conduction velocity and minimal F wave latency studies did not show significant changes in all study groups.
Conclusion: LLLT is proved to be an effective, easy, handy, relatively safe, and noninvasive treatment modality for idiopathic CTS of mild – moderate severity. Broadening the spectrum of wavelengths and changing the power density and energy doses and enrolment of cases which has already been treated surgically still a hopeful view of using LLLT in CTS treatment for further investigations.
Background: Polycystic ovary syndrome (PCOS) is a common disorder in women in the reproductive age associated with disturbance of reproductive, endocrine and metabolic functions. The pathophysiology of PCOS appears to be multifactorial and polygenic.
Objective: To measure the level of prostate –specific antigen (PSA) and to evaluate the value of prostatic specific antigen as a marker of hyperandrogenism in women with PCOS.
Patients and Methods: One hundred women were entrolled in this study, 50 women were PCOS group and the remainder was healthy women served as control group. Hormonal profile (serum testosterone, luteinizing hormone (LH), follicle stimulating hormone (FSH) levels were measured. Ferriman-Gallway Score (FGS) was as
background:
In this paper we report the use of supersonic jet laser induced fluorescence (LIF) spectroscopy to facilitate the study of the spectra of some organometallic sandwich compounds particularly the metallocenes. The charge-transfer processes within these compounds, especially ligand to metal charge transfer within decamethylrhenocene ( - C5 Me5)2 Re were of particular interest. The spectrum shows a high degree of structures, indicating that there are several levels populated and these molecules are able to undergo many possible transitions
The co-occurrence of metabolic syndrome with type 2 diabetes mellitus (T2DM) will potentiate the morbidity and mortality that may be associated with each case. Fasting triglycerides-glucose index (TyG index) has been recommended as a useful marker to predict metabolic syndrome. Our study aimed to introduce gender-specific cut-off values of triglycerides- glucose index for diagnosing metabolic syndrome associated with type 2 diabetes mellitus. The data were collected from Baghdad hospitals between May - December 2019. The number of eligible participants was 424. National cholesterol education program, Adult Treatment Panel III criteria were used to define metabolic syndrome. Measurement of fasting blood glucose, lipid pro
... Show MoreThis study aims to find out the effectiveness of a cognitive-behavioral counseling program in enhancing self-management in reducing the academic procrastination of tenth-grade male students. The sample consisted of (26) male students divided into an experimental group of (13) students and a control group of (13) students. Two scales of self-management and academic procrastination were used, prepared by the researcher. The counseling program was prepared by the researcher. The results showed the program's effectiveness in enhancing self-management and reducing academic procrastination in the posttest, as it showed the continuation of this enhancement in self-management and the increase in the reduction of procrastination in the follow-up
... Show MoreBackground: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1
... Show MoreOne of the troublesome duties in chemical industrial units is determining the instantaneous drop size distribution, which is created between two immiscible liquids within such units. In this work a complete system for measuring instantaneous droplet size is constructed. It consists of laser detection system (1mW He-Ne laser), drop generation system (turbine mixer unit), and microphotography system. Two immiscible liquids, water and kerosene were mixed together with different low volume fractions (0.0025, 0.02) of kerosene (as a dispersed phase) in water (as a continuous phase). The experiments were carried out at different rotational speed (1180- 2090 r.p.m) of the turbine mixer. The Sauter mean diameter of the drops was determined by la
... Show MoreThis paper presents on the design of L-Band Multiwavelength laser for Hybrid Time Division Multiplexing/ Wavelength Division Multiplexing (TDM/WDM) Passive Optical Network (PON) application. In this design, an L-band Mulltiwavelength Laser is designed as the downstream signals for TDM/WDM PON. The downstream signals ranging from 1569.865 nm to 1581.973 nm with 100GHz spacing. The multiwavelength laser is designed using OptiSystem software and it is integrated into a TDM/WDM PON that is also designed using OptiSystem simulation software. By adapting multiwavelength fiber laser into a TDM/WDM network, a simple and low-cost downstream signal is proposed. From the simulation design, it is found that the proposed design is suitable to be used
... Show MoreSolid state blue laser source is a solid state laser include generation of IR laser light 1064 nm and companied with other wavelength 810 nm that invented from other active medium (Tm:ZBLAN) and non-linear crystal (CLBO) are used to generate fourth harmonic of the resultant wavelength 1874 nm that is blue laser light of 460nm. Several optical component have been designed by multilayer dielectric structure and anti reflection coating analysis. By using MATLAB soft ware, the simulation done and used the following non linear material (ZrO2, HfO2, MgO, SiO, Ta2O5 CaF2) and other linear material (ZnO, MgF2, GaAs, AlAs, BaF2, LiF, TiO2) as coating material. The result showed that as more quarter wave layers are added to the structure, the refl
... Show MoreHigh-intensity laser-produced plasma has been extensively investigated in many studies. In this demonstration, a new spectral range was observed in the resulted spectra from the laser-plasma interaction, which opens up new discussions for new light source generation. Moreover, the characterizations of plasma have been improved through the interaction process of laser-plasma. Three types of laser were incorporated in the measurements, continuous-wave CW He-Ne laser, CW diode green laser, pulse Nd: YAG laser. As the plasma system, DC glow discharge plasma under the vacuum chamber was considered in this research. The plasma spectral peaks were evaluated, where they refer to Nitrogen gas. The results indicated that the
... Show More