Preferred Language
Articles
/
iqjmc-614
Effect of ureteric stone location on the success rate of ureteroscopic Holmium laser lithotripsy
...Show More Authors

Background: Ureteral stone can cause obstructive uropathy and subsequent deterioration of renal function. There are four treatment options for ureteral calculi: lithotripsy, ureteroscopy, laparoscopic ureterolithotomy, and open stone surgery. Holmium YAG laser is an excellent intracorporial lithotripter for all kinds of stones. Accordingly, there is steady increase in number of ureteroscopic laser lithotripsy operations in the managmant of Ureteral stone.

Objectives: this study was designed to demonstrate the effect of ureteric stone location on the success rate of ureteroscopic Holmium laser lithotripsy in the management of ureteric stones.

Patients and Methods: Ninety middle-aged patients of either sex (35.9 ± 10.8 years) with ureteric stone (9.5 ± 3 mm) were treated with semiregid ureteroscopy using Holmuim: YAG laser as an intracorporial lithotripter. In 32 patients (35%) the stone were located in the lower ureter, 22 patients (24%) in middle ureter and in 36 patients (40%) in the upper ureter. Then all the patients were followed up on day 1 and 4 weeks for clearance of stone by plain abdominal radiography and abdominal ultrasonography.

Results: the stone free rates 4 weeks after the treatment were 66% for upper, 75 % for middle and 87.5% for lower ureteric stones.  In 12 patients (13%)cannot be possible to  reach the stone, six patients (6.6 %) had proximal stone migration and treated later on by extracorporeal lithotripsy after double-J stent placement. Ureteral perforation occurred in 7 patients (7.7%), all managed by double-J stent placement except 1patient needed an open surgical treatment..

Conclusion: YAG laser lithotripsy is efficacious modality of treatment for ureteric stones especially in lower ureter and it is a safe and technically feasible and in early experience, it is preferred to start with more distal stones.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The effect of operational efficiency on some financial indicators according to the CAMEL model of banking financial stability: An applied research on a sample of Iraqi private banks for the period 2010-2020
...Show More Authors

Abstract

          The research aims to determine the nature of the Iraqi market in terms of banking financial stability and the extent impact of the operational efficiency on it, Accordingly, chosen 15 relational banks were chosen as an intentional sample that could represent the Iraqi banking system for the period 2010-2020. The operational efficiency variable was measured according to the data envelope model, and banking financial stability used  CAMELS model which includes five indicators (capital adequacy, asset quality, management quality, profitability, and liquidity), so for testing the research hypotheses used the random regression model by adopting the S

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2012
Journal Name
2012 8th International Conference On Wireless Communications, Networking And Mobile Computing
Performance Evaluation of Location Management in GSM Networks
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref
Publication Date
Wed May 31 2023
Journal Name
Iraqi Geological Journal
A Survey of Infill Well Location Optimization Techniques
...Show More Authors

The maximization of the net present value of the investment in oil field improvements is greatly aided by the optimization of well location, which plays a significant role in the production of oil. However, using of optimization methods in well placement developments is exceedingly difficult since the well placement optimization scenario involves a large number of choice variables, objective functions, and restrictions. In addition, a wide variety of computational approaches, both traditional and unconventional, have been applied in order to maximize the efficiency of well installation operations. This research demonstrates how optimization approaches used in well placement have progressed since the last time they were examined. Fol

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Stimulation of Phagocytic Activity of Human Polymorphonuclear Leukocytes in Vitro Using 10 mW He-Ne Laser.
...Show More Authors

Stimulative effect of 10 mW He-Ne laser on the phagocytic activity of human polymorphonuclear leukocytes( PMNs) has been studied in vitro. Normal polymorphonuclear leucocytes were isolated from the human peripheral blood. A mixture of 0.25 ml of Hanks solution, 0.25 ml of serum, 0.25 ml of Candida albicans suspension and 0.25 ml of PMNs suspension was prepared. The samples of mixture of PMNs and Candida were subdivided in 1 ml ependrof tubes and irradiated to He-Ne laser for 1, 3, 5, 10 and 20 min. The diameter of the irradiated area was 0.8 cm. For calculation of Phagocytic index before and after irradiation, the samples were incubated (37°C) at 5, 15, 30, 60 min. The slides of samples were prepared and stained using Giemsa stain. The

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study on Electrochemical Grinding Parameters on Hardness and Material Removal Rate for Stainless Steel 316
...Show More Authors

Electrochemical Grinding (ECG) process is a mechanically assisted electrochemical process for material processing. The process is able to successfully machine electrically conducting harder materials at faster rate with improved surface finish and dimensional control. This research studies the effect of applied current, electrolyte concentration, spindle speed and the gap between workpiece and tool on hardness and material removal rate during electrochemical grinding for stainless steel 316. The characteristic features of the electrochemical grinding process are explored through Taguchi-design-based experimental studies. The better hardness can be obtained at 10 A of the current, 150 g/l of the electrolyte concentration, 0.3 mm of gap an

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
A comparative study of the effects of argon laser and continuous Nd: YAG laser on blood vessel
...Show More Authors

Several types of laser are used in experimental works in order to study the effects of laser on blood vessel. They differ from each other by a lot of properties mainly in wavelength, energy of the laser and pulse duration. In this study argon laser (488 nm- 514 nm) and continuous Nd: YAG laSer (1064 nm), have been applied to 50 samples of sheep blgod tesselS. Histologically, tha results of the study were different According to the txpe of L`sar used; apgon larer had distrabtave effects on $he blood vessal while continuous Nd: YAG laser Appeaped to be the safesd one on the blmod vessel architecture. This study concluded that argoj laser has da-aging ef&ect on

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
THE IMPACT OF CURRENCY AUCTION ON THE VARIABILITY OF THE EXCHANGE RATE IN IRAQ 2004-2015
...Show More Authors

The transition states that Iraq economy lived it after 2003, and the change in tools used by monetary policy based on C.B.I law 56 in 2004, under the especially situation for the economy (structural imbalances and the weakness of banking & financial sector).

The monetary policy adopted the inflation targeting policy to mantain the monetary stability in the economy and considered it an incubator for future growth. It used the exchange rate as a nominal anchor to achieve the goal (because the rentier of economy, finance Shallowness & separation between real sector and finance sector, all this cause the normal channel to transfer the effect of monetary policy (interest rate) ineffective.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 09 2025
Journal Name
Iraqi Journal Of Science
Effect of Diode Laser (805) nm on alpha-toxin production and antibiotic sensitivity of Staphylococcus aureus
...Show More Authors

View Publication
Publication Date
Sun Aug 01 2021
Journal Name
Journal Of Engineering
The Intelligent Auto-Tuning Controller Design Based on Dolphin Echo Location for Blood Glucose Monitoring System
...Show More Authors

This paper presents an enhancement technique for tracking and regulating the blood glucose level for diabetic patients using an intelligent auto-tuning Proportional-Integral-Derivative PID controller. The proposed controller aims to generate the best insulin control action responsible for regulating the blood glucose level precisely, accurately, and quickly. The tuning control algorithm used the Dolphin Echolocation Optimization (DEO) algorithm for obtaining the near-optimal PID controller parameters with a proposed time domain specification performance index. The MATLAB simulation results for three different patients showed that the effectiveness and the robustness of the proposed control algorithm in terms of fast gene

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Engineering
An Experimental Study of Compaction and Strength of Stabilized Cohesive Soil by Stone Powder
...Show More Authors

The In this experimental study, natural stone powder was utilized to improve a cohesive soil’s compaction and strength properties. According to the significant availability of limestone in the globe, it has been chosen for the purpose of the study, in addition to considering the existing rock industry massive waste. Stone powder was used in percentages of 4, 8, 12, 16% replaced from the soil weight in dry state. Some of cohesive soil’s consistency, shear, and compaction properties were depicted after improvement. The outcomes yielded in significant amendments in the experimented geotechnical properties after stone powder addition considering 60 days curing period. Cohesion and friction angle were notably increased by

... Show More
View Publication Preview PDF
Crossref