Objectives: (I) to describe the hemodynamic and electrocardiograph (ECG) responses in patients with acute myocardial infraction (AMI) to a low level treadmill test (2) to assess the safety of low-level treadmill testing after AMI (3) to determine if information gained from the test can be used for discharge planning.
Methods: 50 consecutive patients with AMI were subjected for symptoms limited treadmill testing in the CCU of University Teaching Hospital Iraqi medical College, their age range was from 30-70 with mean age of 55 years. Blood pressure, heart rate, and ECG during a low level treadmill test studied 6 days after AML They were divided into two groups, group I those who could finish the test and group 2 those who couldn't finish the test.
Results: 38 patients (76 percent) completed the test. Fatigue was the main reason for the early stopping of the test. Between the rest and maximum exercise there was 12% increase in systolic blood pressure, 6 percent increase in diastolic blood pressure and 17 percent increase in heart rate. The resting systolic blood pressure, diastolic blood pressure and heart rate were significantly increased (p<0.05) in the patients who were unable to finish the test. ST segment elevation or depression> I mm was seen in 5 patients.
Conclusions: This low level treadmill testing was safe if it is done under supervised conditions. It provides an objective information about the patient’s readiness for discharge and a help in future management of the patients.
A Schiff base ligand 1,2-[Bis-(1-phenyl-2-hydroxy-2-phenyl)-amino] benzene [H2L] and its complexes with (Cu(II), Zn(II), Cd(II) and Hg(II)) ions are reported. The ligand was prepared by condensation reaction of ortho-phenylenediamine in methanol under reflux with benzoin to give the mentioned ligand. Then the complexes were synthesized by adding corresponding metal salts to the solution of the ligand in methanol under reflux with 1:1 metal to ligand ratio. On the basis of molar conductance I.R., U.V-Vis, HPLC, chloride content and atomic absorption the complexes may be formulated as K2[M(L)Cl2][MII = Cu, Zn, Cd and Hg]. The data of these measurements suggest a tetrahedral geometry to complexes Cu, Zn, Cd and Hg.
University campuses in Iraq are substantial energy consumers, with consumption increasing significantly during periods of high temperatures, underscoring the necessity to enhance their energy performance. Energy simulation tools offer valuable insights into evaluating and improving the energy efficiency of buildings. This study focuses on simulating passive architectural design for three selected buildings at Al-Khwarizmi College of Engineering (AKCOE) to examine the effectiveness of their cooling systems. DesignBuilder software was employed, and climatic data for a year in Baghdad was collected to assess the influence of passive architectural strategies on the thermal performance of the targeted buildings. The simulations revealed that the
... Show MoreMicrowave heating is caused by the ability of the materials to absorb microwave energy and convert it to heat. The aim of this study is to know the difference that will occur when heat treating the high strength aluminum alloys AA7075-T73 in a microwave furnace within different mediums (dry and acidic solution) at different times (30 and 60) minutes, on mechanical properties and fatigue life. The experimental results of microwave furnace heat energy showed that there were variations in the mechanical properties (ultimate stress, yielding stress, fatigue strength, fatigue life and hardness) with the variation in mediums and duration times when compared with samples without treatment. The ultimate stress, yielding stress and fatigue streng
... Show MoreThe effects of T-shaped fins on the improvement of phase change materials (PCM) melting are numerically investigated in vertical triple-tube storage containment. The PCM is held in the middle pipe of a triple-pipe heat exchanger while the heat transfer fluid flows through the internal and external pipes. The dimension effects of the T-shaped fins on the melting process of the PCM are investigated to determine the optimum case. Results indicate that while using T-shaped fins improves the melting performance of the PCM, the improvement potential is mainly governed by the fin’s body rather than the head. Hence, the proposed T-shaped fin did not noticeably improve melting at the bottom of the PCM domain; additionally, a flat fin is ad
... Show MoreHigh-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreBackground: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts.
Objectives:<
... Show MoreThe pretreatment process can be considered one of the important processes in wastewater treatment, especially coagulation process to decrease the strength of many pollutants. This paper focused on using powdered date seeds as natural coagulant in addition to chemical coagulants (alum and ferric chloride) to find the optimum dosage of each coagulant that makes efficient removal of turbidity and chemical oxygen demand (COD) from domestic wastewater as a pretreatment process, then finding the optimum combined dosages of date seeds with alum, date seeds with ferric chloride that make efficient removal for both pollutants. Concerning turbidity, the optimum dosage for date seeds, alum and ferric chloride were 40 mg/l (79%), 70
... Show MoreBackground: Pulpotomy is an accepted treatment for the management of cariously exposed pulps in symptom free primary molars to achieve one of the most important goals for Pedodontists, which is the retention of the pulpally involved deciduous teeth healthy until the time of normal exfoliation. The purpose of this study was to evaluate the relative success of pulpotec, formocresol and Mineral Trioxide Aggregate (MTA) in cariously exposed primary molar teeth, using clinical and radiographical examinations. Materials and methods: Thirty nine children with 45 primary molars requiring pulpotomy were selected in this study, 15 teeth treated by each type of pulpotomy medicament. Clinical and radiographical follow up for the patients was performed
... Show MoreBackground: preeclampsia is characterized by endothelial dysfunction with vasoconstriction due to cell adhesion molecules or mediators released by defective placentation. Soluble platelet selectin, one of the cell adhesion molecules, is elevated in many inflammatory conditions including preeclampsia.
Objective: To investigate if soluble platelet-selectin levels can be used as a marker for adverse outcomes in pregnancy complicated with sever preeclampsia
Patients and methods:This study involved 115 pregnant women in their third trimester of pregnancy; divided into Group A: involves 25 pregnant women with preeclampsia complicated by intrauterine growth restriction.Group B: involves 35 pregnant women with preeclampsia without intraute