Objectives: (I) to describe the hemodynamic and electrocardiograph (ECG) responses in patients with acute myocardial infraction (AMI) to a low level treadmill test (2) to assess the safety of low-level treadmill testing after AMI (3) to determine if information gained from the test can be used for discharge planning.
Methods: 50 consecutive patients with AMI were subjected for symptoms limited treadmill testing in the CCU of University Teaching Hospital Iraqi medical College, their age range was from 30-70 with mean age of 55 years. Blood pressure, heart rate, and ECG during a low level treadmill test studied 6 days after AML They were divided into two groups, group I those who could finish the test and group 2 those who couldn't finish the test.
Results: 38 patients (76 percent) completed the test. Fatigue was the main reason for the early stopping of the test. Between the rest and maximum exercise there was 12% increase in systolic blood pressure, 6 percent increase in diastolic blood pressure and 17 percent increase in heart rate. The resting systolic blood pressure, diastolic blood pressure and heart rate were significantly increased (p<0.05) in the patients who were unable to finish the test. ST segment elevation or depression> I mm was seen in 5 patients.
Conclusions: This low level treadmill testing was safe if it is done under supervised conditions. It provides an objective information about the patient’s readiness for discharge and a help in future management of the patients.
A low speed open circuit wind tunnel has been designed, manufactured and constructed at the Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the first part of the work; that is the design calculations, simulation and construction. It will be followed by a second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70 m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow disturbances in the test section.
... Show MoreA low speed open circuit wind tunnel has been designed, manufactured and constructed at the
Mechanical Engineering Department at Baghdad University - College of Engineering. The work is one of
the pioneer projects adapted by the R & D Office at the Iraqi MOHESR. The present paper describes the
first part of the work; that is the design calculations, simulation and construction. It will be followed by a
second part that describes testing and calibration of the tunnel. The proposed wind tunnel has a test
section with cross sectional area of (0.7 x 0.7 m2) and length of (1.5 m). The maximum speed is about (70
m/s) with empty test section. The contraction ratio is (8.16). Three screens are used to minimize flow
distu
Our aim was to investigate the changes in the myocardium stiffness index for patients suffering from systemic hypertension, and to assess their left ventricular performance. We studied 263 hypertensive patients and 166 healthy subjects as a control group. By using conventional Doppler echocardiography, the following parameters were measured—Left ventricular end diastolic diameter, left ventricular end systolic diameter, transmitral early velocity, isovolumic relaxation time, and isovolumic contraction time. Tissue Doppler imaging (TDI) was used in the measurements of the early mitral annular velocity (Ea) and the diastolic stiffness was obtained by calculating the ratio E\Ea\LVIDd. Index myocardial performance (IMP) was calculated
... Show MoreLow-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreThe current study involves an experimental investigation of plasma main parameters of a DC discharge with a hollow cathode (HCD) geometry in air using apertures of different diameters from the hollow cathode (1, 1.5, 2, and 2.5 cm). A tiny Langmuir probe is used to investigate the plasma properties. The HCD was operated at constant power of 12.4 W and gas pressures ranging between 0.1 to 0.8 torr. It was observed that the operational conditions strongly affect the electron temperature and density, while the hollow cathode diameter has not much influence. The main important observation was that at relatively high air pressure (>0.4 torr) two electron temperatures were obtained, while at relatively low pressure (<0.4 torr)
... Show MoreBackground: stress test (EST) is one of the main diagnostic and prognostic tests for ischemic heart disease. However, its usefulness depends on achieving target heart rate, then chronotropic incompetence and poor exercise capacity limits its utility. We evaluated the usefulness of atropine administration during the EST to decrease the number of tests with inconclusive results in these patients.
Patients &Methods: We carried out this study in Ibn AI-Bitar Teaching Hospital from September 2007 to December 2008 and comprised of 210 patients undergoing EST. In subjects experiencing fatigue when they achieved 50-75% of target heart rate (THR), or those who failed to achieve their THR, atropine was adm
The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s
... Show MoreBackground: Using Laparoscopic approach, Cholecystectomy is made hazardous by distortion of the anatomy of Calot's triangle by acute or chronic inflammation and dense omental adhesions. Laparoscopic subtotal cholecystectomy (LSTC) without cystic duct ligation is an alternative to conversion to open surgery in difficult cases.
Results: Fifty cases of LSTC were performed, 32 of them were males and the remaining 18 patients were females. The age of study group was ranged (18 – 75) years with a median of (46) year. The median operating time was about 90 min. and the mean duration of hospital stay was 7.3±2.2 days. There were 8 patients (16%) with postoperative bile leak, most of them recover s
Background: Appreciation of the crucial role of risk factors in the development of coronary artery disease (CAD) is one of the most significant advances in the understanding of this important disease. Extensive epidemiological research has established cigarette smoking, diabetes, hyperlipidemia, and hypertension as independent risk factors for CADObjective: To determine the prevalence of the 4 conventional risk factors(cigarette smoking, diabetes, hyperlipidemia, and hypertension) among patients with CAD and to determine the correlation of Thrombolysis in Myocardial Infarction (TIMI) risk score with the extent of coronary artery disease (CAD) in patients with unstable angina /non ST elevation myocardial infarction (UA/NSTEMI).Methods: We
... Show More