Preferred Language
Articles
/
iqjmc-1512
Non Enhanced Helical Ct Scan In Visualization Of Normal Appendix
...Show More Authors

Purpose: To evaluate the frequency of visualization, thickness, and anatomical features of the normal appendix at nonenhanced helical computed tomography (CT).
Materials and methods : Two radiologists prospectively iterpreted, in consensus, the abdominal CT scans of 140 patients who were examined for renal colic assessment. They
were blinded to patients' surgical history regarding a previous appendectomy. No contrast material was used. The frequency of visualization, and the two – wall thickness of normal
appendix were recorded, as well as the anatomical features of the appendix and the effect of adequasy of intraperitoneal fat on identification of the appendix.
Results : The prevalence of appendectomy was 9% (13 of 140 patients). The sensitivity, specificity, positive and negative predictive values, and accurasy of visualization of normal
appendix were 77%, 85%, 98%, 27%, and 77% respectively. The frequency of visualization was lower in patients with less nintraperitoneal fat. The mean thickness of normal appendix
if no intraluminal content was visualized was 6.6 mm+ 1.0 mm, and the mean thickness excluding visualized intraluminal content was 3.6mm + 0.8 mm.
Conclusion : Most normal appendices are seen at nonenhanced helical CT. The thickness of normal appendix, when the content is not recognizable, overlaps the values currently used to
diagnose appendicitis at CT.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Dec 31 2022
Journal Name
Al-kindy College Medical Journal
Pulmonary CT findings in Patients Recovered from COVID-19 Pneumonia
...Show More Authors

Background: The COVID-19 infection is a more recent pandemic disease all over the world and studying the pulmonary findings on survivors of this disease has lately commenced.

Objective: We aimed to estimate the cumulative percentage of whole radiological resolution after 3 months from recovery and to define the residual chest CT findings and exploring the relevant affecting factors.

Subjects and Methods: Patients who had been previously diagnosed with COVID-19 pneumonia confirmed by RT-PCR test and had radiological evidence of pulmonary involvement by Chest CT during the acute illness were included in the present study. The radiol

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jul 04 2010
Journal Name
Journal Of The Faculty Of Medicine Baghdad
CT Image Segmentation Based on clustering Methods.
...Show More Authors

Background: image processing of medical images is major method to increase reliability of cancer diagnosis.
Methods: The proposed system proceeded into two stages: First, enhancement stage which was performed using of median filter to reduce the noise and artifacts that present in a CT image of a human lung with a cancer, Second: implementation of k-means clustering algorithm.
Results: the result image of k-means algorithm compared with the image resulted from implementation of fuzzy c-means (FCM) algorithm.
Conclusion: We found that the time required for k-means algorithm implementation is less than that of FCM algorithm.MATLAB package (version 7.3) was used in writing the programming code of our w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 31 2021
Journal Name
Karbala International Journal Of Modern Science
Adaptive reconstruction of the heterogeneous scan line ETM+ correction technique
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Nonlinear Optical Properties of PMMA Composites Using Z-Scan Technique
...Show More Authors

The nonlinear refractive index and the nonlinear absorption coefficient of unmodified and functional poly(methyl methacrylate) PMMA films were studied before and after the addition of the filler by the z-scan technique, using a Q-switched Nd:YAG laser at two wavelengths: 532 nm and 1064 nm, and at three input energies (13, 33 and 53) mJ. Both linear and nonlinear refractive indices and absorption coefficients of polymer films were studied by using UV-VIS spectrophotometer. The results show that the creation of functional PMMA from unmodified PMMA will increase the nonlinear optical properties in the functional PMMA/copper matrix more than in the unmodified PMMA/copper matrix. Hence, the functional PMMA appears promising as a useful third

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Correlating CT findings of stroke with hyperglycemia in acute ischemic stroke patients
...Show More Authors

Background: Studies show that diabetic patients have a higher incidence of ischemic stroke than non-diabetic patients. In the Framingham study the incidence of thrombotic stroke was 25 times higher in diabetic men and 36 times higher in diabetic women than in those without diabetes

Objectives: aim of this study to analyze topography in diabetic patients.

Type of study:  Cross sectional study.

Methods: 48 patients with acute stroke were classified into 4 groups: euglycemic, stress hyperglycemia, newly diagnosed diabetics, and known diabetics.

Results:no significant differences were found in the type, site or size of st

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Water Flow Visualization And Velocity Measurement Using Hydrogen Bubble Generation Technique In Low Speed Open Channel
...Show More Authors

Visualization of water flow around different bluff bodies at different Reynolds number ranging (1505 - 2492) was realized by designing and building a test rig which contains an open channel capable to ensure water velocity range (4-8cm/s) in this channel. Hydrogen bubbles generated from the ionized water using DC power supply are visualized by a light source and photographed by a digital camera. Flow pattern around a circular disk of (3.6cm) diameter and (3mm) thickness, a sphere of (3.8cm) diameter and a cylinder of
(3.2cm) diameter and (10cm) length are studied qualitatively. Parameters of the vortex ring generated in the wake region of the disk and the separation angle of water stream lines from the surface of the sphere are plott

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Apr 01 2012
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Accuracy and safety of CT guided transthoracic needle biopsy
...Show More Authors

Background:Image guided transthoracic needle biopsy (TTNB) has great diagnostic value for the definitive characterization of lung lesions and is an established primary procedure to diagnose pulmonary nodules. It is traditionally performed as an outpatient procedure. It is safe, accurate, sensitive, and can obviate surgical procedure.
Objective: to assess the accuracy and safety of CT-guided TTNB in Baghdad Teaching Hospital 
Patients & Methods: From December 2009 to September 2011, we conducted a prospective study of 43 consecutive outpatient and inpatient lung biopsies. An informed consent was obtained from the patients. No sedation is required. All biopsies were performed using CT guidance withou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Investigation of the Effect of Curvature Ratio on Heat Transfer in Double Pipe Helical Heat Exchanger
...Show More Authors

Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also r

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
Role of Multi-Detector CT Angiography in Assesmente of Athrosclerotic Coronary Artery Disease
...Show More Authors

Background:  Imaging has a critical role in the diagnosis and evaluation of cardiac diseases, beginning with chest radiography and fluoro-scopy and progressing to coronary angio-graphy, echocardiography, nuclear medicine and recently  multidetector computed tomo-graphy (MDCT) as well as magnetic resonance (MR) imaging

Objective: To highlight the role of Multi-detector CT in the evaluation of coronary artery disease and its importance of being noninvasive diagnostic technique.

Methods: A cross sectional study for 20 patients. Patients were asked to fast 6 hours prior to the examination and the patients with heart rates above 65 beats per minute were given cardio-

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Nov 28 2018
Journal Name
Al-khwarizmi Engineering Journal
Effect of Using Combined Square Nozzle & winglet with Helical Tape on Thermal Characteristics in Tube Heat Exchanger
...Show More Authors

Influence of combined square nozzle with helical tape inserted in a constant heat flux tube on heat transfer enhancement for turbulent airflow for Reynolds number ranging from 7000 to 14500 were investigated experimentally. Three different pitch ratios for square nozzle (PR = 5.8, 7.7 and 11.6) according to three different numbers of square nozzle (N = 3, 4 and 5) and constant pitch ratios for helical tape were used. The results observed that the Nusselt number and friction factor for combination with winglets were found to be up to 33.8 % and 21.4 %, respectively higher than nozzle alone for pitch ratio PR=5.8. The maximum value of thermal performance for using combination with winglets was about 1.351 for pitch ratio= 5.8. Nusselt numb

... Show More
View Publication Preview PDF
Crossref