Background: Antiphospholipid syndrome (APS) is a disorder in which vascular thrombosis and / or recurrent pregnancy losses occur in a patient who has laboratory evidence of antibodies against phospholipids or phospholipids binding protein cofactor. Usually the patient presents at an age between 35- 45 years, with equal male to female ratio. Mostly they present with thrombosis or pregnancy complication. A quarter of the patients have thrombocytopenia and about one fifth have hemolytic anemia. The diagnosis rests on the criteria set as the Revised classification criteria for the Antiphospholipid syndrome
Patients and Methods; During the period from 1st Jan. 2002 until the 1st Jan. 2006,24 patients who met the criteria of APS (according to Revised classification criteria for the Antiphospholipid syndrome) were included in the study. The diagnosis of deep venous thrombosis (DVT) was done by using Doppler study of the selected organ,
while brain CT and magnetic resonance imaging were used to diagnose cerebrovascular thromboses.Serological evidence of APA were either an abnormal KCT and KCT index and/or a positive aCL antibody test on 2 occasions.
Results : Three quarter of our patients were females, more than half of them aged 21-30 years ,54.16% of our patients presented with thrombosis the commonest site of which was DVT of lower extremities. Abortion alone was the presenting problem in two patients and two patients presented with thrombosis following abortion Another two patients presented with bleeding problems. Gathering the history; follow up abortion occurred in ten of the thirteen premenapausal married ladies, of whom five had more than three abortions.\Laboratory evaluation revealed anemia in 8 patients (33.33% ) and thrombocytopenia in 5 patients (20.8% ).The KCT and KCT index were suggestive of APS in 14 of the 23 patients tested
(60.86%)and the aCL was positive in 15 of the 19 tested patients (78.94 %).
Conclusion, We think that our study, although small, highlights some of the clinical and laboratory findings of this syndrome in Iraqi patients, larger studies are needed for better
evaluation.
Length of plasma generated by dc gas discharge under different vacuum pressures was studied experimentally. The cylindrical discharge tube of length 2m was evacuated under vacuum pressure range (0.1-0.5) mbar at constant external working dc voltage 1500V. It was found that the plasma length (L) increased exponentially with increasing of background vacuum air pressure. Empirical equation has been obtained between plasma length and gas pressure by using Logistic model of curve fitting. As vacuum pressure increases the plasma length increases due to collisions, ionizations, and diffusions of electrons and ions.
Introduction: Articaine was developed in 1969, with reported advantages which are increased potency, increased duration of its anesthetic effect and superior diffusion through bony tissue. The effectiveness of using 4% articaine infiltration for extraction of mandibular molar teeth in comparison to 2% lidocaine inferior alveolar nerve block is not settled yet. Aim: The aim of this study was to evaluate the effectiveness of using 4% articaine infiltration for extraction of mandibular molars by comparing it to the use of 2% lidocaine inferior alveolar nerve block in terms of success, the volume of local anesthetic agents and the pain experienced during the procedure. Materials and methods: A prospective randomized controlled study included
... Show MorePreviously, many empirical models have been used to predict corrosion rates under different CO2 corrosion parameters conditions. Most of these models did not predict the corrosion rate exactly, besides it determined effects of variables by holding some variables constant and changing the values of other variables to obtain the regression model. As a result the experiments will be large and cost too much. In this paper response surface methodology (RSM) was proposed to optimize the experiments and reduce the experimental running. The experiments studied effects of temperature (40 – 60 °C), pH (3-5), acetic acid (HAc) concentration (1000-3000 ppm) and rotation speed (1000-1500 rpm) on CO2 corrosion performance of t
... Show MoreThe using of waste products as a recycled material was one of the most important studies for saving money and reduces the pollution. Mortar and concrete mixes with (10, 20 and 30)% of brick, glass and tile powder as replacement by weight of cement was investigated. The concrete mixes using brick or glass as 10%replacement of cement exhibited enhancement in compressive strength about (6, 4.7 and 2.0)% and (7.2, 5.6 and 2)% at age 7, 28 and 90 days respectively compared to reference mix. The 20% replacement of glass powder also showed an increase in the compressive strength up to (8, 6.3 and 4) %at age 7,28 and 90 days respectively compared to reference mix. Finally concrete mix using (10, 20 and 30) % tile powder as replacement of cement sho
... Show MoreIn order to understand the effect of the number of piles (N), the history response of dynamic pile load in piled raft system and deflection time history of piled raft under repeated impact load applied on the center of piled raft resting on loose sand, laboratory model tests were conducted on small-scale models. The results of experimental work are found to be dynamic load increase with increase height of drop, the measured repeated dynamic load time history on the center of piled raft was close approximately to three a half sine wave shape with small duration in about (0.015 Sec). The maximum peak of impact loads occurs in pile and deflection time history occur after at the time of the peak repeated impact loads, dynamic pile load
... Show MoreGenerally the a.c. conductivity shows a power law in frequency s () where the exponent s ≤ 1. As the frequency goes to zero the conductivity become frequency independent. The a.c. conductivity was studied for the Ge1-xSex thin films to see how the selenium contents affect the permittivity and the permeability for the Ge1-x Sex. The thin films prepared by thermal evaporation at room temperature and under vacuum (~2 x10-5toor) using Edward coating unit model 306A. From the relation between ln conductivity and ln w, the effect of selenium contents in Ge1-x Sex thin films on the exponent value, the relaxation time and the maximum barrier height. An algebric fitting method for circles and circular arcs was used to find the permit
... Show MoreThe structural, optical and electrical properties of ZnS films prepared by vacuum evaporation technique on glass substrate at room temperature and treated at different annealing temperatures (323, 373, 423)K of thickness (0.5)µm have been studied. The structure of these films is determined by X-ray diffraction (XRD). The X-ray diffraction studies show that the structure is polycrystalline with cubic structure, and there are strong peaks at the direction (111). The optical properties investigated which include the absorbance and transmittance spectra, energy band gab, absorption coefficient, and other optical constants. The results showed that films have direct optical transition. The optical band gab was found to be in the range t
... Show More