Background: To find an operation that can be effectively carried out in both adults and children, equally applicable in the elective as well as in the emergency situation and for the good – risk as well as the poor – risk patients. Done by expert and junior surgeons in a short time.
Patients and Methods: Twenty patients with portal hypertension and bleeding varices aged 9-45 years were treated with shunting procedures (group 1, n=10), or a modified Sugiura operation (group 2, n=10) in accordance with the following therapeutic protocol: after resuscitation and diagnostic endoscopy, an emergency modified Sugiura operation was carried out if bleeding could not be controlled over 24 hours. When bleeding could be controlled, the patients underwent full investigation and were then treated with either shunting procedure or with a modified Sugiura operation. The Fisher exact probability test was applied for statistical analysis.
Results: Patients were evaluated at 1-3 years. The rates for operative deaths, recurrent hemorrhage, encephalopathy, late deaths, and patient survival at 1-3 years were as follows: 30%, 10%, 40%, 10% and 60% for group 1; 10%, 0%, 0%, 10%, and 80% for group 2, respectively. Within 3 months after the modified Sugiura operation, varices disappeared in most of the patients and hypersplenism was relieved in all.
Conclusion: We conclude that the modified Sugiura operation is probably a reasonable treatment for variceal hemorrhage because it is effective in arresting hemorrhage and it’s recurrence, with no encephalopathy, and a good survival rate.
Recently, research has focused on non-thermal plasma (NTP) technologies as a way to remove volatile organic compounds from the air stream, due to its distinctive qualities, which include a quick reaction at room temperature. In this work, the properties of the plasma generated by the dielectric barrier discharge (DBD) system and by a glass insulator were studied. Plasma was generated at different voltages (3, 4, 6, 7, 8 kV ) with a fixed distance between the electrodes of 5 mm, and a constant argon gas flow rate of (2.5) I/min. DBD plasma emission spectra were recorded for each voltage. The Boltzmann plot method was used to calculate the electron temperature in the plasma ( ), and the Stark expansion method was used to calculate the elec
... Show Moresix specimens of the Hg0.5Pb0.5Ba2Ca2Cu3-y
Superconducting compound Bi2Sr2-xYxCa2Cu3O10+δ were Synthesized by method of solid state reaction, at 1033 K for 160 hours temperature of the sintering at normal atmospheric pressure where substitutions Yttrium oxide with Strontium. When Y2O3 concentration (0.0, 0.1, 0.2, 0.3, 0.4 and 0.5). All specimens of Bi2Sr2Ca2Cu3O10+δ superconducting compounds were examined. The resistivity of electrical was checked by the four point probe technique, It was found th
Necessary and sufficient conditions for the operator equation I AXAX n*, to have a real positive definite solution X are given. Based on these conditions, some properties of the operator A as well as relation between the solutions X andAare given.
Diabetes Mellitus (DM) is a risk factor for fungal infections, including onychomycosis. The study aims to determine the prevalence of toenail onychomycosis in diabetic patients and its correlation with associated factors, identify the causative agents and compare the fungal culture findings with the real-time polymerase chain reaction (RT-PCR) findings of diagnosing 6 fungal isolates. A total of 126 diabetic patients were included between November 2020 to June 2021. Nail samples were subjected to potassium hydroxide 20%. Culture was done on Sabouraud dextrose agar medium (SDA), both with and without cycloheximide. Identification of non-dermatophytic molds was based on colony characteristics, colony reverse, cello-tape flag meth
... Show MoreThis paper is used for solving component Volterra nonlinear systems by means of the combined Sumudu transform with Adomian decomposition process. We equate the numerical results with the exact solutions to demonstrate the high accuracy of the solution results. The results show that the approach is very straightforward and effective.
In this paper, An application of non-additive measures for re-evaluating the degree of importance of some student failure reasons has been discussed. We apply non-additive fuzzy integral model (Sugeno, Shilkret and Choquet) integrals for some expected factors which effect student examination performance for different students' cases.
A program in Visual Basic language was designed to calculate the time interval of radio storm by predict their type at specific Local Time (LT) from Baghdad location, such storms result from the Central Meridian Longitude (CML) of system ΙΙΙ for Jupiter and phase of Io’s satellite (ФIo). These storms are related to position of Io (Io- A,B,C,D). The input parameters for this program were the observer’s location (longitude), year, month and day. The output program results in form of tables provide the observer information about the date and the LT of beginning and end of each type of emitted storm. The year 2011 was taken to apply the results within twelve month; the results of the time interval of radio storm were between (0.08h-5
... Show MoreBackground: Big birth weight is one of the important factors affecting the perinatal morbidity & mortality. It may result in an irreversible squeal because of birth trauma & fetal asphyxia.
Patients & Methods: This is a prospective study of 50 singleton macrosomic newborns weighting 4000 g & more aged 1-3 days admitted in the neonatal care unit of Children Welfare Teaching Hospital & Baghdad Teaching Hospital during a 6 months period from 1st of March to 1st of September 2010. The maternal & neonatal records were reviewed & infant morbidities including hypoglycemia, respiratory distress, feeding intolerance, birth injury & associated anomalies were discussed. All the in
In this paper, an inexpensive, simple and well-accurate process of the generation of bimetallic silver Ag//gold Au core//shell is colloidal metal nanoparticles (MNPs). This is achieved via an atmospheric pressure non-thermal plasma glow discharge between two electrodes. One of these electrodes is a capillary tube placing over solution about (1 cm) that acts as the cathode, while the other electrode is a metal disk immersed in the solution and acts as an anode. Glow discharge process carried out at room temperature using a home-made cell with (6 KV) applied voltage and direct current (DC) about (1.8 mA) for different discharge periods. A wide range of bimetallic Ag//Au colloidal MNPs was rapidly synthesized as a result of non-thermal plas
... Show More