Background:
Angiogenesis plays a crucial role in tumorigensis; several reports have described a significant increase in microvessel density (MVD) in colorectal carcinogenesis There are
several methods to measure the angiogenesis in neoplasms, but immunohitochemistry seems to be the mainstay of all. This method enable us to measure the tumor microvessel densities highlighted by using antibodies directed against endothelial cell markers like CD31,CD34 or others; then assessment of MVD by manual count of the number of microvessels in what appears to be the most vascular area of the tumor(called the hot spot) using a protocol described by Weidner et al.Automated cellular imaging system is used to analyze
immunohistochemically stained slides .studies have shown that the device offers accurate precision and reproducibility of immunostained slide analysis exceeding that possible with
manual evaluation which was the prevalent method.
Aims of the study:
To assess the angiogenesis in normal, adenomatous (benign) and malignant colorectal tissues using CD34 and the microvessels will be measured both manually by hot spot
method as the MVD and by the use of computerized image analysis system as fraction area ,we correlate between microvessels density and fraction area with various
clinicopathological parameters in colorectal cancer (CRC), and to a compare between the results which obtained from both methods.
Methods:
Paraffin embedded archival materials from 50 cases including three normal resection (non tumoruos) margins, 12 benign colonic lesions and 35 colonic adenocarcinoma were
used . 5mm section were cut and they were stained by anti CD34 antibody Angiogenesis was measured as MVD by two methods : manually by light microscope and by a computer
image analysis system (as fraction area). Then the MVD and fraction area were correlated with different clinicopathological parameters.
Results :
This study demonstrate that there is a statistical difference in MVD and fraction area in both hot spot method and CIAS respectively between benign and malignant tumors . P value
< 0.05 in hot spot method and less than 0.001 in CIAS and there was highly significant correlation between MVD and fraction area with the grade . There was significant increase
in MVD and fraction area from well differentiated to moderately differentiated and to poorly differentiated .There was no significant correlation between MVD and lymph node
involvement by hot spot method but CIAS proved a significant correlation between fraction area and lymph node involvement.Both methods (hot spot and CIAS) proved no
significant correlation with age , sex , size of the tumor , site of the tumor , stage of the tumor and the number of lymph node involverment.
For the determination of metoclopramide hydrochloride (MCPD) in pharmaceutical formulations, a rapid and straightforward spectrophotometric method has been proposed. The method involves diazotizing the main amino group of MCPD with sodium nitrite followed by coupling reaction with reagent 1,7-Dihydroxynaphthalene (1,7-DHN) to form a stable and colored compound in alkaline medium of sodium hydroxide which showed a maximum absorbance intensity at the wavelength 578 nm. The linearity of developed method has ranged from 1.0 - 15 µg.ml-1 while the molar absorptivity 2.9867x104 l.mol-1.cm-1, RSD% was less than 1.11%. While the LOD and LOQ were 0.059 µg.ml-1
... Show MoreIn the present study, the removal of zinc from synthetic waste water using emulsion liquid membrane extraction technique was investigated. Synthetic surfactant solution is used as the emulsifying agent. Diphenylthiocarbazon (ditizone) was used as the extracting agent dissolved in carbon tetrachloride as the organic solvent and sulfuric acid is used as the stripping agent. The parameters that influence the extraction percentage of Zn+2 were studied. These are the ratio of volume of organic solvent to volume of aqueous feed (0.5-4), ratio of volume of surfactant solution to volume of aqueous feed (0.2-1.6), pH of the aqueous feed solution (5-10), mixing intensity (100-1000) rpm, concentration of extracting agent (20-400) ppm, surfactant co
... Show MoreIn the literature, several correlations have been proposed for hold-up prediction in rotating disk contactor. However,
these correlations fail to predict hold-up over wide range of conditions. Based on a databank of around 611
measurements collected from the open literature, a correlation for hold up was derived using Artificial Neiral Network
(ANN) modeling. The dispersed phase hold up was found to be a function of six parameters: N, vc , vd , Dr , c d m / m ,
s . Statistical analysis showed that the proposed correlation has an Average Absolute Relative Error (AARE) of 6.52%
and Standard Deviation (SD) 9.21%. A comparison with selected correlations in the literature showed that the
developed ANN correlation noticeably
Colloidal silver nanoparticles were prepared by single step green synthesis using aqueous extracts of the leaves of thyme as a function of different molar concentration of AgNO3 (1,2,3,4 mM(. The Field Emission Scanning Electron Microscopy (FESEM), UV-Visible and X-ray diffraction (XRD) were used to characterize the resultant AgNPs. The surface Plasmon resonance was observed at wavelength of 444 nm. The four intensive peaks of XRD pattern indicate the crystalline nature and the face centered cubic structure of the AgNPs. The average crystallite size of the AgNPs ranged from 18 to 22 nm. The FESEM image illustrated the well dispersion of the AgNPs and the spherical shape of the nanoparticles with a particle size distribution be
... Show MoreMany species are resistant to heavy metals in their surrounding polluted environment and Staphylococcus sp. is an example. This study aimed to isolate and characterize bacteria resistant to heavy metals in the Shatt Al-Arab River in southern Basra, Iraq. Based on the morphology and using Vitek II system, and due to their high resistance to heavy metals (mercury and chromium), two species of Staphylococcus (Staphylococcus lentus and Staphylococcus lugdunensis) were chosen and isolated. The minimum inhibitory concentration (MIC) of the isolates against Hg and Cr was determined after 72 h. of incubation in solid media. All isolates were resistant to Hg (2000 mgL-1) and Cr (4000mgL
... Show MoreA simple, accurate and sensitive spectrophotometric method for the determinaion of epinephrine is described . The method is based on the coordination of Pr (III) with epinephrine at pH 6. Absorbance of the resulting orange yellow complex is measured at 482 nm . A graph of absorbance versus concentrations shows that beer 's low is obeyed over the concentration range (1-50)mg.ml-1 of epinephrine with molar absorpitivity of ( 2.180x103 L.mol-1.cm-1 ), a sandell sensitivity of (0.084 mg.cm-2 ), a relative error of (-2.83%) , a corrolation coffecient (r= 0.9989) and recovery % ( 97.03 ± 0.75 ) depending on the concentration.This method is applied to analyse EP in several commercially available pharmaceutical preparations
... Show MoreThis study suggests using the recycled plastic waste to prepare the polymer matrix composite (PMCs) to use in different applications. Composite materials were prepared by mixing the polyester resin (UP) with plastic waste, two types of plastic waste were used in this work included polyethylene-terephthalate (PET) and Polyvinyl chloride (PVC) with varies weight fractions (0, 5, 10, 15, 20 and 25 %) added as a filler in flakes form. Charpy impact test was performed on the prepared samples to calculate the values of impact strength (I.S). Flexural and hardness tests were carried out to calculate the values of flexural strength and hardness. Acoustic insulation and optical microscope tests were carried out. In general, it is found that UP/PV
... Show MoreThis research involves an indirect Fluorophotometric method for the determination of microgram amount of oxymetazoline hydrochloride in the concentration range 0.1-5.0 g/ml. The method is based on the oxidation of the drug by cerium sulphate solution which is acidic medium where Ce IV is reduced to Ce III which can be excited at 259 nm to give an emitted light at 377 nm which is directly proportional to the concentration of Ce III which is equivalent to Ce IV that is needed to oxidize the studied drug. The average recovery of the method is 100.19% and relative standard deviation (RSD) < 0.37% . The method have been successfully applied to the determination of the studied drug in its pure and pharmaceutical preparations and it wa
... Show MoreThe characteristics of sulfur nanoparticles were studied by using atomic force microscope (AFM) analysis. The atomic force microscope (AFM) measurements showed that the average size of sulfur nanoparticles synthesized using thiosulfate sodium solution through the extract of cucurbita pepo extra was 93.62 nm. Protecting galvanized steel from corrosion in salt media was achieved by using sulfur nanoparticles in different temperatures. The obtained data of thermodynamic in the presence of sulfur nanoparticles referred to high value as compares to counterpart in the absence of sulfur nanoparticles, the high inhibition efficiency (%IE) and corrosion resistance were at high temperature, the corrosion rate or weig
... Show MoreThis research describes a straightforward procedure for extracting the pigment of Methylene Blue (MB) dye from aqueous solutions by utilizing a low-cost, safe, natural, and national source. Batch adsorption experiments were carried out to determine contact time, adsorbent dose, and the starting concentration of the adsorbate. For the analysis, a UV spectrophotometer was employed. Dye adsorption equilibrium was obtained after 120 minutes of contact time. Temkin, Langmuir, and Freundlich isotherm adsorption were used at solution concentrations of (3, 4, 6, and 8) mg/l. Adsorption data is used to predict the pseudo first and pseudo second order kinetic equations, Elovich kinetic models, and intra-particle diffusion using pseudo f
... Show More