Background:
Angiogenesis plays a crucial role in tumorigensis; several reports have described a significant increase in microvessel density (MVD) in colorectal carcinogenesis There are
several methods to measure the angiogenesis in neoplasms, but immunohitochemistry seems to be the mainstay of all. This method enable us to measure the tumor microvessel densities highlighted by using antibodies directed against endothelial cell markers like CD31,CD34 or others; then assessment of MVD by manual count of the number of microvessels in what appears to be the most vascular area of the tumor(called the hot spot) using a protocol described by Weidner et al.Automated cellular imaging system is used to analyze
immunohistochemically stained slides .studies have shown that the device offers accurate precision and reproducibility of immunostained slide analysis exceeding that possible with
manual evaluation which was the prevalent method.
Aims of the study:
To assess the angiogenesis in normal, adenomatous (benign) and malignant colorectal tissues using CD34 and the microvessels will be measured both manually by hot spot
method as the MVD and by the use of computerized image analysis system as fraction area ,we correlate between microvessels density and fraction area with various
clinicopathological parameters in colorectal cancer (CRC), and to a compare between the results which obtained from both methods.
Methods:
Paraffin embedded archival materials from 50 cases including three normal resection (non tumoruos) margins, 12 benign colonic lesions and 35 colonic adenocarcinoma were
used . 5mm section were cut and they were stained by anti CD34 antibody Angiogenesis was measured as MVD by two methods : manually by light microscope and by a computer
image analysis system (as fraction area). Then the MVD and fraction area were correlated with different clinicopathological parameters.
Results :
This study demonstrate that there is a statistical difference in MVD and fraction area in both hot spot method and CIAS respectively between benign and malignant tumors . P value
< 0.05 in hot spot method and less than 0.001 in CIAS and there was highly significant correlation between MVD and fraction area with the grade . There was significant increase
in MVD and fraction area from well differentiated to moderately differentiated and to poorly differentiated .There was no significant correlation between MVD and lymph node
involvement by hot spot method but CIAS proved a significant correlation between fraction area and lymph node involvement.Both methods (hot spot and CIAS) proved no
significant correlation with age , sex , size of the tumor , site of the tumor , stage of the tumor and the number of lymph node involverment.
The study was conducted on twenty dogs from variety breeds to estimate the
incidence of tumor mass and determine the risk factors of survey to cases of a year
in veterinary hospital in Baghdad. The most common clinical signs were, ulceration,
bleeding into lesions in addition to drowsiness, anorexia, fever and the others were
depended tumor's location in dog's body like lameness, lacrimation and bloody
constipation etc.
The results showed 70% of the infected dogs were working with military forces
and 30% of them were pet dogs and we found that the highest percentage of tumor
accrued in dogs aged more than 10 years and the females recorded 60% of infection.
Terrier breed had the highest percentage of infection (
Image processing is an important source for the image
analytical in order to get variable parameters such as the
intensity .In present work it has been found a relation between the tensity and number of pixd in the image , and from this relation we have got in this paper the inten
... Show MoreThe effect of White Place Image ( Test Image ) A4 has been studied as a function of luminous intensity using the t tu un ng gs st te en n l la am mpp and web camera enet. It was found that the tungsten lamp gives almost even intensities for the three color band and lighting composite at low voltage .while at high voltage causes a fare from each other . The statistical characteristic(mean and stander deviation ) results for three colors composites RGB and lighting composites L showed that the mean and stander deviation increases with the increase of voltage possibly owing to the increase image resolution, which reflects the value of stander deviation for the blue band
... Show MoreThe growth of developments in machine learning, the image processing methods along with availability of the medical imaging data are taking a big increase in the utilization of machine learning strategies in the medical area. The utilization of neural networks, mainly, in recent days, the convolutional neural networks (CNN), have powerful descriptors for computer added diagnosis systems. Even so, there are several issues when work with medical images in which many of medical images possess a low-quality noise-to-signal (NSR) ratio compared to scenes obtained with a digital camera, that generally qualified a confusingly low spatial resolution and tends to make the contrast between different tissues of body are very low and it difficult to co
... Show MoreBackground: Cytology is one of the important diagnostic tests done on effusion fluid. It can detect malignant cells in up to 60% of malignant cases. The most important benign cell present in these effusions is the mesothelial cell. Mesothelial atypia can be striking andmay simulate metastatic carcinoma. Many clinical conditions may produce such a reactive atypical cells as in anemia,SLE, liver cirrhosis and many other conditions. Recently many studies showed the value of computerized image analysis in differentiating atypical cells from malignant adenocarcinoma cells in effusion smears. Other studies support the reliability of the quantitative analysisand morphometric features and proved that they are objective prognostic indices. Method
... Show MoreBackground: Thalassemia is a hereditary anemia resulting from defects in hemoglobin production. ?- thalassemia caused by decrease in the production of ?- globin chains affect multiple organs and is associated with cranio-oro-facial deformity which include prominent cheek bones and protrusive premaxilla with depression of the nasal bridge often referred to as “rodent or chip-munk face” with small mandible and Cl.II skeletal relationship. This study aimed to investigate cephalometric craniofacial parameters (skeletal) of ?- thalassemic major patients by using computed tomography and to compare findings with a group of healthy patients in the same age group. Subject, Materials and Method: The study included (40) patients with ?- thalassemi
... Show MoreMany studies have been published to address the growing issues in wireless communication systems. Space-Time Block Coding (STBC) is an effective and practical MIMO-OFDM application that can address such issues. It is a powerful tool for increasing wireless performance by coding data symbols and transmitting diversity using several antennas. The most significant challenge is to recover the transmitted signal through a time-varying multipath fading channel and obtain a precise channel estimation to recover the transmitted information symbols. This work considers different pilot patterns for channel estimation and equalization in MIMO-OFDM systems. The pilot patterns fall under two general types: comb and block types, with
... Show MoreA simple, rapid and sensitive method for the analysis of Atenolol in pure and pharmaceutical preparation as an alternative analytical procedure were developed by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite position (2N90o). The method is based upon the formation of white precipitate for the ion pair compound by phosphomolybidic acid with Atenolol in aqueous medium. The precipitate is measured via the attenuation of incident light and scattering of the incident light in two opposite direction namely +90o and -90o angle were measured. Chemical and physical parameters were investigated. The linearity of Atenolol is ranged from (0.1-11) mmol.L-1, with correlation coefficient r=0.993
... Show MoreBackground: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Resu
... Show More