Background:
To assess the feasibility and early results of non-surgical transcatheter closure of atrial septal detect (ASD) using the Ampiatzer septal Occluder (ASO).
Patients and Methods:
From June 2003 to June 2005, i75 patients with ASD secundum, age range 3- 65 years, female to male ratio of 3:2. were evaluated for transcatheter closure using ASO at Ibn Al-
Bitar Hospital for Cardiac Surgery. Transthoracic echocardiography was performed in al patients using standard suhxyphoid, apical, parasternal and suprasternal views. In all
patients, the procedure was done under general anesthesia.
Results:
Based on transesophageal echocardiography (TEE) Findings, 60 patients (33.7%) did not meet the criteria for transcatheter closure (40 females and 20 males). One hundred
Fifteen patients were found to have ASDs suitable for device closure. The device was successfully deployed in allpatients except 11 of them (104/115) (90.4%).
In 11 cases with failure of ASO deployment, 6 patients had small floppy inferior rims which were not able to hold the device after the Minnesota wegeal maneuver. One adult
patient with a large ASD secundum and second degree AV block developed complete heart block during the procedure before the deployment of the occluder. One of them dislodged
into the left atrium (LA) immediately after deployment because of a very small inferior rim and the other one dislodged into the LA because of descrewing of the cable after multiple
manipulations. Both of them were referred for surgery. An other one of the 11 patients had developed a thrombus in the LA during the procedure because of delay in giving heparin
after placing the guide wire in the left upper pulmonary vein. In the last patient, the procedure was abandoned and the occluder recaptured into the sheath before release from
the cable because the TEE showed that the LA disc encroached on the mitral valve causing mitral stenosis.
Conclusion:
The transcatheter closure of secundum ASD is safe, efficacious with a very low rate of early and Sate complications. It is becoming an increasingly popular alternative to surgical
closure.
Background: The evaluation and staging of renal cell carcinoma (RCC) has dramatically changed with the introduction of cross-sectional imaging. Nowadays, small renal lesions are easily detected by computed tomography (CT) examination while missed by other modalities.
Objective: To determine whether ultrasound (US) or CT scan is the optimum imaging modality for the evaluation of the renal masses.
Patients and methods: This is a comparative study in which 30 patients with hematuria were attending the urological consulting clinic in Ghazzi Al-Harriry hospital, Baghdad, Iraq from May 2016 to July 2017 were subjected to abdominal US and CT scan.
Results:
... Show MoreCore decompression is one of the commonest used techniques in the handling of osteonecrosis of the pre-collapsed head of the femur. Core decompression had succeeded in preserving the hip joint and delaying the requisite for total hip replacement, but it had failed in the induction of osteogenesis in the necrotic area, thus augmenting core decompression with biological agents to induce osteogenic activity. To assess the effects of platelet-rich plasma in non-traumatic avascular necrosis of the hip joint (early stage) after core decompression. Interventional comparative study for twenty-four patients (32 hip joints) with AVN of the head of the femur was involved in this prospective study, and they were separated into two groups of 16
... Show MoreBackground: The problem of difficult gallbladder is not clearly defined and associated with real missing of therapeutic approaches that decreased morbidity. Moreover, the difficult gallbladder was reported as a contributing risk factor for biliary injury due to raised difficulty in surgical dissection within Calot’s triangle. The aim of this study is to determine the surgical outcomes of the open fundus-first cholecystectomy in lowering the rate of lethal intraoperative risks.
Subjects and Methods: Our prospective study conducted during the period of January 2019 to December 2022 at Ibn Sina specialized hospital, Khartoum, Sudan, for two hundred and fifty-three patients underw
... Show MoreBackground: Big birth weight is one of the important factors affecting the perinatal morbidity & mortality. It may result in an irreversible squeal because of birth trauma & fetal asphyxia.
Patients & Methods: This is a prospective study of 50 singleton macrosomic newborns weighting 4000 g & more aged 1-3 days admitted in the neonatal care unit of Children Welfare Teaching Hospital & Baghdad Teaching Hospital during a 6 months period from 1st of March to 1st of September 2010. The maternal & neonatal records were reviewed & infant morbidities including hypoglycemia, respiratory distress, feeding intolerance, birth injury & associated anomalies were discussed. All the in
In all process industries, the process variables like flow, pressure, level, concentration
and temperature are the main parameters that need to be controlled in both set point
and load changes.
A control system of propylene glycol production in a non isothermal (CSTR) was
developed in this work where the dynamic and control system based on basic mass
and energy balance were carried out.
Inlet concentration and temperature are the two disturbances, while the inlet
volumetric flow rate and the coolant temperature are the two manipulations. The
objective is to maintain constant temperature and concentration within the CSTR.
A dynamic model for non isothermal CSTR is described by a first order plus dead
time (FO
Of non-Muslim minorities In the Muslim community
Background: The displacement of artificial teeth during complete denture construction presents major processing errors in the occlusal vertical dimension which were verified at the previous trial denture stage. The aim of this study was to assess the effect of delay in processing after final flask closure and tension application on the vertical acrylic and porcelain teeth displacement of complete dentures constructed from heat cured acrylic and the results were compared with the conventional processing method. Materials and methods: forty samples of identical maxillary complete dentures were constructed from heat polymerized acrylic resin. These samples were subdivided into the following experimental subgroups in which each subgroup contai
... Show MoreIn this research, a non-thermal plasma system was designed and a non-thermal plasma needle was manufactured for argon gas operating at normal atmospheric pressure. The electrical description of this system studied by using two different values of voltages (4.9,8) kV. Where the results showed the small amount of electrical current consumed by the system of plasma needle up to several microns of amps, and the value of the electrical current increase with the increasing gas flow, as well as the results, showed that happen a breakdown voltage at (8) kV when gas flow (4 l/min) causing a slight decrease in the electrical current value.
Background: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union w