Preferred Language
Articles
/
iqjmc-1196
0.1 Second versus 0.2 Second pulse duration of Frequency Doubled Nd: YAGLaser in treatment of Clinically Significant Diabetic Maculopathy.
...Show More Authors

Background: clinically significant macular edema (CSME) is the commonest cause of visual loss in patients with diabetes mellitus and laser focal photocoagulation is the golden standard for treating it. Patients and Methods: A frequency doubled Nd: YAG laser was used to treat all eyes included in this study with diabetic maculopathy. Thirty eyes of three insulin dependent and twenty six non insulin dependent diabetic Iraqi patients were included. The study involved twenty six males, three females and followed for one year. Their ages were ranging between 36- 59 years, all of them from patients attending ophthalmic out-patient department in the medical city in the period between January 2005 and June 2006. Eyes divided in to two groups (fifteen eyes in each group) and the disease severity was taken into account. The first group treated with 0.1 second and second group with 0.2 second pulse duration.
Results: In group (1) improvement of V.A occurred in 19.99% (Statistically significant) and 60% (Statistically significant) in group (2). There was stabilization 80% (Statistically insignificant) in group (1) and 33.33% Stabilization (Statistically significant) in group (2), while worsening only in group (2) 6.67%(Statistically insignificant).
Conclusion: The frequency doubled Nd:YAG laser is effective in controlling diabetic macular oedema when applied in focal treatment. The setting of 100μm 0.2sec., pulse exposure time show more improvement in V.A. than 100μm 0.1sec.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Studying Laser Diode Dynamics with Optical Feedback from 20cm Free Space External Resonator
...Show More Authors

In this experimental study, which was carried out in photonics laboratory at Strathclyde University, UK, dynamics of a multi-Quantum well semiconductor active medium laser, was studied. This is in order to study its emission stability and pulse shape development under the influence of strong optical feedback level with different deriving currents, in the free space transmission medium. An external stable resonator was constructed by inserting high reflectivity dielectric mirror outside the laser output, 20 cm apart from it, which is an extralarge external cavity. Controlling the reflected back optical power was done by using a nonpolarized (50:50) beam splitter. The external resonator supported by focusing (plano-convex) lens in order to

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 14 2020
Journal Name
Materials Science Forum
The Cyclic Fatigue Behavior for 6061-T6 Al Alloy Shafts Processed by Laser Shock Peening
...Show More Authors

The optimal combination of aluminum quality, sufficient strength, high stress to weight ratio and clean finish make it a good choice in driveshafts fabrication. This study has been devoted to experimentally investigate the effect of applying laser shock peening (LSP) on the fatigue performance for 6061-T6 aluminum alloy rotary shafts. Q-switched pulsed Nd:YAG laser was used with operating parameters of 500 mJ and 600 mJ pulse energies, 12 ns pulse duration and 10 Hz pulse repetition rate. The LSP is applied at the waist of the prepared samples for the cyclic fatigue test. The results show that applying 500 mJ pulse energy yields a noticeable effect on enhancing the fatigue strength by increasing the required number of cycles to fracture the

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
New Method for the On-Line Determination of Molybdenum Via New Microphotometric Home Mode Instrument, Using Hight Emitting Diode as a Variable Intensity Radiant Source with a Miniture Photosilicone Diode Detector for System: Molybdenum(VI)-Hydrogen Peroxide-Ammonium Solution
...Show More Authors

This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 25 2021
Journal Name
International Journal Of Drug Delivery Technology
Synthesis, Characterization Of Some Metal Complexes With 3-(Benzo[d]Thaizole-2-Yl)-9-Oxo-6,7,7a,9-Tertrahydro-2H-2,10:4,7-Diepoxyfuro [3,2-f][1,5,3] Dioxazonine–2,4 (3H)–Dicarboxylic Acid. Hydro-chloride (L–as–am) and Study their Biological Activity
...Show More Authors

The reaction of 2-amino-benzothiazole with bis [O,O-2,3,O,O – 5,6 – (chloro(carboxylic) methiylidene) ] – L – ascorbic acid (L-AsCl2) gave new product 3-(Benzo[d]Thaizole-2-Yl) – 9-Oxo-6,7,7a,9-Tertrahydro-2H-2,10:4,7-Diepoxyfuro [3,2-f][1,5,3] Dioxazonine – 2,4 (3H) – Dicarboxylic Acid, Hydro-chloride (L-as-am)), which has been insulated and identified by (C, H, N) elemental microanalysis (Ft-IR),(U.v–vis), mass spectroscopy and H-NMR techniques. The (L-as am) ligand complexes were obtained by the reaction of (L-as-am) with [M(II) = Co,Ni,Cu, and Zn] metal ions. The synthesized complexes are characterized by Uv–Visible (Ft –IR), mass spectroscopy molar ratio, molar conductivity, and Magnetic susceptibility techniques. (

... Show More
Publication Date
Sun Jul 01 2012
Journal Name
Journal Of Techniques مجلة التقني
A STUDY OF SOME TECHNICAL AND ECONOMICAL PARAMETERS FOR MACHINERY UNIT (NEW HOLLAND &DISC PLOW) BY USING THREE DIFFERENT TILT ANGLES دراسة بعض المؤشرات الفنية والأقتصادية للوحدة الميكنية (الجرار نيوهولاند مع المحراث القرصي الثلاثي القلاب) بأستخدام زوايا ميل مختلفة للأقراص
...Show More Authors

Publication Date
Thu Dec 31 2020
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
STUDY THE INHIBITION ACTIVITY OF PURIFIED BACTERIOCIN FROM LOCAL ISOLATION Lactococcuslactis ssp. lactisagainst SOME PATHOGENIC BACTERIAL SPECIES ISOLATED FROM CLINICAL SAMPLES: دراسة الفعالية التثبيطية للبكتريوسين المنقى من العزلة المحلية Lactococcuslactis ssp. Lactis تجاه بعض البكتريا الممرضة المعزولة من عينات سريرية
...Show More Authors

This study aimed to study the inhibition activity of purified bacteriocin produced from the local isolation Lactococcuslactis ssp. lactis against pathogenic bacteria species isolated from clinical samples in some hospitals Baghdad city. Screening of L. lactis ssp. Lactis and isolated from the intestines fish and raw milk was performed in well diffusion method. The results showed that L. lactis ssp. lactis (Lc4) was the most efficient isolate in producing the bacteriocin as well observed inhibitory activity the increased that companied with the concentration, the concentration of the twice filtrate was better in obtaining higher inhibition diameters compared to the one-fold concentration. The concentrate

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Laser Peening on Aluminum Alloy 7049 Using Black Paint Surface Coating
...Show More Authors

Abstract

Black paint laser peening (bPLP) technique is currently applied for many engineering materials , especially for aluminum alloys due to high improvement in fatigue life and strength . Constant and variable   bending fatigue tests have been performed at RT and stress ratio R= -1 . The results of the present  work observed that the significance of the surface work hardening which generated high negative residual stresses in bPLP specimens .The fatigue life  improvement factor (FLIF)  for bPLP constant fatigue behavior was from 2.543 to 3.3 compared to untreated  fatigue and the increase in fatigue strength at 107 cycle was 21% . The bPLP cumulative fatigue life behav

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
The substitutions of Strontium by yttrium and their effects on Bi<sub>2</sub>Sr<sub>2</sub>-<sub>x</sub>Y<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10</sub>+<sub>δ</sub> superconducting compound
...Show More Authors
Abstract<p>Superconducting compound Bi<sub>2</sub>Sr2-<sub>x</sub>Y<sub>x</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> were Synthesized by method of solid state reaction, at 1033 K for 160 hours temperature of the sintering at normal atmospheric pressure where substitutions Yttrium oxide with Strontium. When Y2O3 concentration (0.0, 0.1, 0.2, 0.3, 0.4 and 0.5). All specimens of Bi<sub>2</sub>Sr<sub>2</sub>Ca<sub>2</sub>Cu<sub>3</sub>O<sub>10+δ</sub> superconducting compounds were examined. The resistivity of electrical was checked by the four point probe technique, It was found th</p> ... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Crossref
Publication Date
Tue Jul 20 2021
Journal Name
Materials Science Forum
Red Laser Irradiation Effect on the Structural Properties of MawsoniteCu&lt;sub&gt;6&lt;/sub&gt;Fe&lt;sub&gt;2&lt;/sub&gt;SnS&lt;sub&gt;8&lt;/sub&gt; [CFTS] Thin Films Deposited via Semi-Computerized Spray Pyrolysis Technique
...Show More Authors

The existing investigation explains the consequence of irradiation of violet laser on the structure properties of MawsoniteCu6Fe2SnS8 [CFTS] thin films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser. when the received films were processed by continuous red laser (700 nm) with power (>1000mW) for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time (0,30,45,60,75,90 min) respectively at room temperature.. The XRD diffraction gave polycrysta

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Tue Feb 28 2023
Journal Name
Iraqi Journal Of Science
Beam Shaping Technique for 5-mm Fiber-coupled Laser Diode Bars with Lens Group
...Show More Authors

In the last few years, fiber-coupled diode lasers have shown massive applications in many fields of communication and scientific research. Particularly, the pumping of solid-state lasers is a key application for more powerful diode lasers enabling good solutions in various laser micro methods like metal cutting, sintering, structuring as well as drilling. In this work, a simple beam shaping method is demonstrated for coupling a high-power semiconductor laser diode into multi-mode fiber optic using optical lenses. The optical lenses as beam transformation components are utilized to reshape the asymmetrical irradiation of the diode laser bar and to circularize the laser beam. Using this simple method, compact, high-output-power, and high-b

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref