Background: Techniques of Inguinal hernia repair have seen an evolution from the pure tissue repair to the prosthetic repair and in the recent years past to laparoscopic repair. High recurrence rates using fascia for the hernia repair or the use of sutures under tension prompted the development of polypropylene mesh to reinforce the posterior wall of the inguinal canal.The aim of this study is to compare the post operative results of Lichtenstein mesh technique with Dar ning repair.<br />Patients and methods:-A prospective study of "100" patients with inguinal hernia were conducted to evaluate two methods, of open repair of inguinal hernia Lichtenstein mesh technique with Traditional non-mesh technique (modified Bassini or Darning).Operation were done under general, epidural and local anaesthesia at the surgical units of Baghdad Teaching Hospital and Arbil Teaching Hospital.<br />Results: The study showed that Lichtenstein mesh technique is an effective operation for repair of inguinal hernia with low complication rate and less pain in comparison to the repair by traditional non-mesh technique. Also the results show that, mesh repair group returned to work earlier than non-mesh repair group.<br />Conclusion:Mesh repair of primary inguinal hernia repair is superior to non-mesh repair in term of early postoperative pain , return to the work and recurrence.
Background typhoid fever is the commonest cause of non traumatic terminal ileal perforation in our study with a grave postoperative morbidity & mortality depending upon preoperative time delay &/or type of surgical intervention practiced.
Objective to evaluate the frequency of non traumatic causes of terminal ileal perforation, their presentations,perforation-operation interval effect on complications, as well as different modalities of treatment and their complications.
Methods the study is a prospective study of 82 patients with perforation of terminal ileum diagnosed by explorative laparatomy in Al Kindy teaching hospital ,Baghdad, Iraq from April 2008- December 2010, all of the patien
summary
In this search, we examined the factorial experiments and the study of the significance of the main effects, the interaction of the factors and their simple effects by the F test (ANOVA) for analyze the data of the factorial experience. It is also known that the analysis of variance requires several assumptions to achieve them, Therefore, in case of violation of one of these conditions we conduct a transform to the data in order to match or achieve the conditions of analysis of variance, but it was noted that these transfers do not produce accurate results, so we resort to tests or non-parametric methods that work as a solution or alternative to the parametric tests , these method
... Show MoreIn this research we have been studied the 3rd order spherical aberration for an optical system consisted of obscured circular aperture with non central circular obscuration through the calculation of point spread function (P.S.F) in presence of the obscuration in the center and comparing the obtained results with that results of moving obscuration far away from the center, where the results showed significant improvement for(P.S.F) value. The study was done of different obscurities ratios in addition to the different 3rd order spherical aberration values (W40=0.25 ,0.5 ,0.75 ,1 ).
To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving th
... Show MoreRetainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.
To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).
A two-arm parallel groups single-centre randomized c
The class of quasi semi -convex functions and pseudo semi -convex functions are presented in this paper by combining the class of -convex functions with the class of quasi semi -convex functions and pseudo semi -convex functions, respectively. Various non-trivial examples are introduced to illustrate the new functions and show their relationships with -convex functions recently introduced in the literature. Different general properties and characteristics of this class of functions are established. In addition, some optimality properties of generalized non-linear optimization problems are discussed. In this generalized optimization problems, we used, as the objective function, quasi semi -convex (respectively, strictly quasi semi -convex
... Show MoreThe aim of the current paper is to resolve the non-uniqueness in gravity interpretation through searching for singular points in the gravity field that are coincide with causative body vertices. The Absolute Second Horizontal Gradient (ASHG) method is used to locate the horizontal reference location of the body, while its amplitude could be used to define body corner depth. Intelligent use of the ASHG method could help in differentiating between basin and intrusion structures from their gravity effect and could facilitate the interpretation in forward modeling and constrain inversion modeling to maximum limit. The method is tested by using many synthetic examples with different types of shapes. A real data is used to examine the method a
... Show MoreBackground: Bowel preparation prior to
colonic surgery usually includes antibiotic
therapy together with mechanical bowel
preparation which may cause discomfort to the
patients, prolonged hospitalization and water
& electrolyte imbalance.
Objective: to assess whether elective colon
and rectal surgery may be safely performed
without preoperative mechanical bowel
preparation.
Method: the study includes all patients who
had elective large bowel resection at Medical
City – Baghdad Teaching Hospital between
Feb, 2007 to Jan, 2010. Emergency operations
were not included. The patients were randomly
assigned to the 2 study groups (with or without
mechanical bowel preparation.
Results: A to