Background: Techniques of Inguinal hernia repair have seen an evolution from the pure tissue repair to the prosthetic repair and in the recent years past to laparoscopic repair. High recurrence rates using fascia for the hernia repair or the use of sutures under tension prompted the development of polypropylene mesh to reinforce the posterior wall of the inguinal canal.The aim of this study is to compare the post operative results of Lichtenstein mesh technique with Dar ning repair.<br />Patients and methods:-A prospective study of "100" patients with inguinal hernia were conducted to evaluate two methods, of open repair of inguinal hernia Lichtenstein mesh technique with Traditional non-mesh technique (modified Bassini or Darning).Operation were done under general, epidural and local anaesthesia at the surgical units of Baghdad Teaching Hospital and Arbil Teaching Hospital.<br />Results: The study showed that Lichtenstein mesh technique is an effective operation for repair of inguinal hernia with low complication rate and less pain in comparison to the repair by traditional non-mesh technique. Also the results show that, mesh repair group returned to work earlier than non-mesh repair group.<br />Conclusion:Mesh repair of primary inguinal hernia repair is superior to non-mesh repair in term of early postoperative pain , return to the work and recurrence.
Background: Adenoiditis is a common cause of otitis media with effusion (OME) in children & perhaps OME is one of the most common diseases leads to hearing impairment in children with subsequent impairment of speech development & learning difficulties , however, treatment remains controversial. Objectives: To evaluate if there is a significant advantage of tympanostomy tube insertion in association with adenoidectomy over adenoidectomy in association with myringotomy alone in treatment of children with OMEType of the study: This is a prospective study. Patients & methods: The study consisted from 63 children diagnosed as cases of bilateral OME & variable degrees of adenoid hypertrophy. The patients were divided randomly i
... Show MoreThe unconventional techniques called “the quick look techniques”, have been developed to present well log data calculations, so that they may be scanned easily to identify the zones that warrant a more detailed analysis, these techniques have been generated by service companies at the well site which are among the useful, they provide the elements of information needed for making decisions quickly when time is of essence. The techniques used in this paper are:
- Apparent resistivity Rwa
- Rxo /Rt
The above two methods had been used to evaluate Nasiriyah oil field formations (well-NS-3) to discover the hydrocarbon bearing formations. A compu
... Show MoreThis study was conducted to delineate diversity and species composition of non-diatoms planktonic algae in Hoor- Al- Azime marshes, Iran. The samples were collected from four sites at monthly basis from April 2011 to March 2012. A total 88 taxa were identified, out of which (40 taxa, 45.45%) belonging to Cyanophyta followed by Chlorophyta (29 taxa, 32.96%), Euglenophyta (18 taxa, 20.45%) and (1 taxa, 1.14%) of Dinophyta recorded. Comparing species richness (65 taxa, 34.76%) at Shat- Ali (St4) was the highest and the lowest (34 taxa, 18.18%) was observed at Rafi (St2). Species occurrence was associated with temperature where in summer (66 taxa) and (25 taxa) encountered winter. The phy
In this paper, we will provide a proposed method to estimate missing values for the Explanatory variables for Non-Parametric Multiple Regression Model and compare it with the Imputation Arithmetic mean Method, The basis of the idea of this method was based on how to employ the causal relationship between the variables in finding an efficient estimate of the missing value, we rely on the use of the Kernel estimate by Nadaraya – Watson Estimator , and on Least Squared Cross Validation (LSCV) to estimate the Bandwidth, and we use the simulation study to compare between the two methods.
In this study, we investigate the run length properties for the EWMA charts with time - varying control limits, and fast initial Response (FIR), for monitoring the mean of a normal process with a known standard deviation , by using non - homogeneous markov chain approach.
Background: In the present study used device jet plasma needle with atmospheric pressure which generates non thermal plasma jet to measure treatment potent with plasma against pathogenic bacteria founded in UTI was inactivated with plasma at 10 sec,
Objective:. This work included the application of the plasma produced from the system in the field of bacterial sterilization , where sample of Gram- negative bacteria (Escherichia coli) were exposed to intervals (1-10)second . Midstream Urine samples swabs were obtained from patients with urinary tract infections.
Type of the study: Cross -sectional study.
Methods: The work were used i
... Show MoreBackground: Obesity is an evolving major health problem in both developed and developing countries. Non-hypertensive obese may have an elevated Morning Blood pressure surge (MBPS), which is associated with increased risk for cardiac events (CE) independently of office and ambulatory blood pressure (BP). Non-hypertensive obese also may have a blunted nocturnal decrease in BP during the night, while healthy normotensive non-obese individuals have a 10%–20% nocturnal decrease in blood pressure (BP) during the night or dipping. Thus, 24-hour ambulatory blood pressure monitor (ABPM) is the gold standard to evaluate MBPS and dipping profile in non-hypertensive obese individuals.
Objectives: 
... Show MoreThin films of CuPc of various thicknesses (150,300 and 450) nm have been deposited using pulsed laser deposition technique at room temperature. The study showed that the spectra of the optical absorption of the thin films of the CuPc are two bands of absorption one in the visible region at about 635 nm, referred to as Q-band, and the second in ultra-violet region where B-band is located at 330 nm. CuPc thin films were found to have direct band gap with values around (1.81 and 3.14 (eV respectively. The vibrational studies were carried out using Fourier transform infrared spectroscopy (FT-IR). Finally, From open and closed aperture Z-scan data non-linear absorption coefficient and non-linear refractive index have been calculated res
... Show MoreMental systems in ontological discourse turned into deliberative systems, derived from the non-coordinated thought that motivated ontological discourse, as an incomplete thought, after it became close to reason; Between creation and prevention, between reasoning and creation, between submission and ambition, the result of an interconnected entity that slays one another from one another, and intersects with one another, to produce a special pattern each time, completely different from its predecessor or to provide a path for the coordination of others, which is outside the linguistic event, or part From it, signs and marks, produced to a large extent M., and united the signs; to return again in a circular and rotational movement to produc
... Show More