Background: Study the correlation between the left ventricular end diastolic volume (LVEDV), ejection fraction (EF) and the development of arrhythmia.
Patients and methods: Two hundreds patients with documented acute coronary syndrome and myocardial infection with dysrhythmia documented by ECG and holter monitoring assessed at the cardiac department at Baghdad teaching hospital over the period Jan-Dec 2007. These dysrhythmias were corelated with left ventricular end diastolic volume and ejection fraction.
Results: The patients were divided into 4 groups according to LVEDD and EF. The 1st group, 40 patients (20%) found to have non sustained ventricular tachycardia was associated with higher LVEDD (62-72mm) and low EF (30-39%) in comparison with other groups. A 2nd group of 80 patients (40%) have occasionally ventricular ectopic, their left ventricular end diastolic dimension is (52-58 mm) and ejection fraction in higher than the 3rd group 10 patients (5%) who had atrial fibrillation were having normal left ventricular end diastolic volume but ejection fraction was 45%. A 4th group of 40 patients (20%) were having occasional atrial ectopic have both normal ejection fraction and left ventricular end diastolic volume, the remaining 30 patients (15%) from the total did not develop any arrhythmia and their left ventricular end diastolic volume and ejection fraction were normal considered an control groups.
Conclusion: It was found that the development of arrhythmia is very significantly correlated with the abnormal increased left ventricular end diastolic volume and more lowering of ejection fraction.
A new, simple and sensitive spectrophotometric method for the determination of Thymol in pure and mouth wash preparations has been proposed in this study. The method was based on oxidation of 2,4-dinitrophenylhydrazine with potassium periodate and coupling with Thymol in alkaline medium to form an intense violet water-soluble dye that is stable and has a maximum absorption at 570 nm. A graph of absorbance versus concentration shows that Beer’s law was obeyed over the concentration range of 0.25-10 μg.mL-1 of Thymol, with detection limits of 0.063 μg.mL-1. All experimental parameters that affect the development and stability of the colored product were carefully studied and the proposed method was successfully applied to the determina
... Show MoreBackground: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the
... Show MoreA key agreement protocol (KAP) is a fundamental block in any cryptosystem since it ensures secure communication between two parties. Furthermore, KAP should include advanced features in limited-resource environments such as IoT, in which this protocol must be lightweight and efficient in consuming resources. Despite the Elliptic Curve Diffie-Hellman (ECDH) algorithm having often been considered efficient in providing an acceptable security degree with less resource consumption, it has suffered from weakness against Man-In-The-Middle Attacks (MITMA). This paper presents two versions of the Variant Elliptic Curve Diffie-Hellman (VECDH) algorithms as a key agreement protocol. The security analysis indicates that the proposed algori
... Show MoreIs in this research review of the way minimum absolute deviations values based on linear programming method to estimate the parameters of simple linear regression model and give an overview of this model. We were modeling method deviations of the absolute values proposed using a scale of dispersion and composition of a simple linear regression model based on the proposed measure. Object of the work is to find the capabilities of not affected by abnormal values by using numerical method and at the lowest possible recurrence.
This paper aimed to determine the Optimal Reliable Frequency (ORF) that can maintain certain connection link between different transmitter/receiver stations laid over the Iraqi territory. Three different transmitting sites were chosen as tested stations located in the northern, central, and southern regions of Iraq. These sites are Mosul, Baghdad, and Basra, respectively. In this study, the years 2009 and 2014, which represent the minimum and maximum years of solar cycle 24, were chosen to examine the effect of low and high solar activity on the determined ORF. The datasets of the Best Usable Frequency (BUF) were calculated using the ASAPS international communication model. An analytical study was made on the generated BUF parameter data
... Show MoreBacteriological characteristics of Tigris river water were assessed monthly to monitor the impact of pollutants of Medical City waste water for the period from January to June-2013. Four stations were selected for the study, the first station placed before the Medical City Complex (500 meters). The second station represent Medical City sewage discharge into the river, where represents the study area. The third station placed (500 meters) after the second station, and the forth station is located on (2000 meters) after the second station.
Samples collected monthly to monitor the changes of water indicators showed that: Total Bacterial Count (10000 to 2700000 cells/1 ml), Total Coliform (200-3700 cells/100 ml), Fecal Coliform (100-2400
The improvement in Direction of Arrival (DOA) estimation when the received signals impinge on Active-Parasitic Antenna (APA) arrays will be studied in this work. An APA array consists of several active antennas; others are parasitic antennas. The responses to the received signals are measured at the loaded terminals of the active element. The terminals of the parasitic element are shorted. The effect of the received signals on the parasites, i.e., the induced short-circuit current, is mutually coupled to the active elements. Eigen decomposition of the covariance matrix of the measurements of the APA array generates a third subspace in addition to the traditional signal and noise subspaces generated by the all-active ante
... Show More