Preferred Language
Articles
/
ioaTrYYBIXToZYALtKMf
Analytical study on torsional behavior of concrete beams strengthened with fiber reinforced polymer laminates using softened truss model
...Show More Authors

This study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment to accomplish the analysis, solve the appropriate equations, and calculate the torsional moment and angle of twist at all points. The parametric study considered the effect of effective fiber strain to reach a better prediction for the full torsional behavior. The model was able to predict the torsional behavior of the RC beams strengthened with FRP materials before and after cracking stages with reasonable accuracy.

Scopus Clarivate Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical Behavior of Phosphotized Reinforcing Steel in Concrete in Presence of Sugar Can Ash
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Sep 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Molar Buccal Tubes Front and Back Openings Dimensions and Torsional Play
...Show More Authors

Background/: Buccal tubes are orthodontic attachments used on the posterior teeth instead of bands, so it is important to focus on the effect of their properties on orthodontic treatment. The aims of the present in vitro study are to evaluate and compare the buccal tube front and back openings dimensions and the torsional play angle of six different brands. Materials and Methods: The samples consisted of Single bondable, non-convertible first molar buccal tubes from six brands supplied from six companies (Dentaurum, Forestadent, Ormco, 3M, American Orthodontic, A-Star). Regarding tube opening dimension, ten buccal tubes of each brand were examined by an optical microscope. Each tube was fixed during examination using synthetic mud and orie

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Nov 04 2022
Journal Name
Journal Of Optics
Coreless optical fiber for hemoglobin (HB) sensing with bilayer based on surface plasmon resonance
...Show More Authors

In this work, an optical fiber biomedical sensor for detecting the ratio of the hemoglobin in the blood is presented. A surface plasmon resonance (SPR)-based coreless optical fiber was developed and implemented using single- and multi-mode optical fibers. The sensor is also utilized to evaluate refractive indices and concentrations of hemoglobin in blood samples, with 40 nm thickness of (20 nm Au and 20 nm Ag) to increase the sensitivity. It is found in practice that when the sensitive refractive index increases, the resonant wavelength increases due to the decrease in energy.

View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Oct 31 2019
Journal Name
Al-kindy College Medical Journal
Behavior Management of Children with Autism
...Show More Authors

Background: Pervasive Developmental Disorder (PDD) is a term refers to the overarching group of conditions to which autism spectrum disorder (ASD) belongs .

Objective: This study was designed to determine the existing behavior of children with autism in dental sitting, the behavior improvements in recall dental visits and evaluate the improvement in oral hygiene with using specific visual pedagogy chart.

Type of the study: Cross-sectional study.

Methods: Forty children of both genders, ages ranged from 4 – 6 years having primary teeth only were selected whose medical history included a diagnosis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Optical Fiber Technology
Enhancing refractive index sensitivity using micro-tapered long-period fiber grating inscribed in biconical tapered fiber
...Show More Authors

View Publication
Scopus (20)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Writing of a Bragg Grating on a D-shaped Optical Fiber Using the KrF Excimer Laser
...Show More Authors

Fiber Bragg Grating has many advantages where it can be used as a temperature sensor, pressure sensor or even as a refractive index sensor. Designing each of this fiber Bragg grating sensors should include some requirements. Fiber Bragg grating refractive index sensor is a very important application. In order to increase the sensing ability of fiber Bragg gratings, many methods were followed. In our proposed work, the fiber Bragg grating was written in a D-shaped optical fiber by using a phase mask method with KrFexcimer. The resultant fiber Bragg grating has a high reflectivity 99.99% with a Bragg wavelength of 1551.2 nm as a best result obtained from a phase mask with a grating period of 1057 nm. In this work it was found that the rota

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 06 2018
Journal Name
Al-khwarizmi Engineering Journal
Bone Defect Animal Model for Hybrid Polymer Matrix Nano Composite as Bone Substitute Biomaterials
...Show More Authors

Addition of bioactive materials such as Titanium oxide (TiO2), and incorporation of bio inert ceramic such as alumina (Al2O3), into polyetheretherketone (PEEK) has been adopted as an effective approach to improve bone-implant interfaces. In this paper, hot pressing technique has been adopted as a production method. This technique gave a homogenous distribution of the additive materials in the proposed composite biomaterial. Different compositions and compounding temperatures have been applied to all samples. Mechanical properties and animal model have been studied in all different production conditions. The results of these new TiO2/Al2O3/PEEK biocomposites with different

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jul 17 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Comparative study of retention of fiber-reinforced post at middle and cervical one thirds of root canal cemented by polycarboxylate and zinc phosphate cements measured at different storage times
...Show More Authors

Background: The purpose of this study was to compare regional bond strength at middle and cervical thirds of the root canal among glass fiber-reinforced composite (FRC) endodontic posts cemented with different cements, using the push-out test to compare the performance (retention) of two types of luting cements; polycarboxylate cement and Zinc phosphate cement used to cement translucent fiber post and to compare the result of the push-out test at different storage times;1 week ,1month and 2 months. Materials and methods: Ninety caries-free, recently extracted single-rooted human teeth with straight root canals was used in this study, The root canals were endodontically instrumented at a working length of 0.5 mm from the apex by m

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Phase Behavior Compositional Model for Jambour Cretaceous Oil Reservoir
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
The Influence of No-Core Fiber Length on the Sensitivity in Fiber Optic Strain Sensor
...Show More Authors

The influence of sensing element length of no-core fiber strain sensor has been studied and experimentally demonstrated, four different lengths of 125 μm diameter no-core fiber is fused between two standard single-mode fibers and bi-directionally strained, the highest obtained sensitivity was around 16.37 pm με -1 which was exhibited in the shortest no-core fiber segment, to the best of our knowledge this is the first study of the influence of no-core fiber strain sensors length on sensor sensitivity. The proposed sensor can be used in many opto-mechanical applications such as, structural health monitoring, aerospace vehicles and airplane components monitoring.

View Publication Preview PDF