Objectives: To determine the contributing risk factors to adult nephrolithiasis patients.
Methodology: A descriptive study was conducted to determine the contributing risk factors to
Adults nephrolithiasis starting from December 2007 to September 2008. A purposive "nonprobability"
sample of (100) patients with nephrolithiasis was selected of those who were
admitted to the hospitals, attending the Urology Consultation Clinic and Extracorporeal Shock
Wave Lithotripsy Department. The study instrument consists of two parts. The first part is
related to the patients' demographic variables and the second part is constructed to serve the
purpose of the study. The total number of items in the questionnaire was (85) ones.
Content Validity of the instrument was determined through the use of a panel of (12) expert in
the field of the study. Reliability of the instrument was estimated through the pilot study. Data
were analyzed through descriptive data analysis and the inferential data analysis approaches.
New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete
... Show MoreThe new organic reagent 2-[Benzo thiazolyl azo]-4,5-diphenyl imidazole was prepared and used as complexing agent for separation and spectrophotometric determination of Cu2+ ion in some samples include plants, soil, water and human blood serum. Initially determined all factors effect on extraction method and the results show optimum pH was (pHex=9), optimum concentration was 40?g/5mLCu2+ and optimum shaking time was (15min.), as well stoichiometry study appears the complex structure was 1:1 Cu2+: BTADPI. Interferences effect of cations were studied. Synergism effect shows MIBK gave increasing in distribution ratio (D). Organic solvent effect appears there is no any linear relation between dielectric constant for organic solvent used and dis
... Show MoreA new, simple, sensitive and fast developed method was used for the determination of methyldopa in pure and pharmaceutical formulations by using continuous flow injection analysis. This method is based on formation a burgundy color complex between methyldopa andammonium ceric (IV) nitrate in aqueous medium using long distance chasing photometer NAG-ADF-300-2. The linear range for calibration graph was 0.05-8.3 mmol/L for cell A and 0.1-8.5 mmol/L for cell B, and LOD 952.8000 ng /200 µL for cell A and 3.3348 µg /200 µL for cell B respectively with correlation coefficient (r) 0.9994 for cell A and 0.9991 for cell B, RSD % was lower than 1 % for n=8. The results were compared with classical method UV-Spectrophotometric at λ max=280 n
... Show MoreA simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show MoreThis work presents a completely new develop an analyzer, named NAG-5SX1-1D-SSP, that is simple, accurate, reproducible, and affordable for the determination of cefotaxime sodium (CFS) in both pure and pharmaceutical drugs. The analyzer was designed according to flow injection analysis, and conducted to turbidimetric measurements. Ammonium cerium nitrate was utilized as a precipitating agent. After optimizing the conditions, the analysis system exhibited a linear range of 0.008-27 mmol. L-1 (n=29), with a limit of detection of 439.3 ng/sample, a limit of quantification of 0.4805 mg/sample, and a correlation coefficient of 0.9988. The repeatability of the responses was assessed by performing six successive injections of CFS at concentra
... Show MoreBackground: Vitamin D deficiency/ insufficiency is common in different age groups in both genders especially among pregnant women and neonates where it is associated with several adverse outcomes including preeclampsia and preterm delivery. Objectives: To assess the extent of vitamin D deficiency/ insufficiency among mothers and their neonates and some factors related to it and identify some adverse outcomes of the deficiency/ insufficiency on neonates (preterm birth and low birth weight). Subject and Methods: A cross-sectional study was conducted on 88 Iraqi pregnant women and neonates admitted to “Al-Elwiya teaching hospital for maternity” in Baghdad- Al-Rusafah from 1st of June 2019 to 31st of August 2019. Dat
... Show MoreBackground: Vitamin D deficiency/ insufficiency is common in different age groups in both genders especially among pregnant women and neonates where it is associated with several adverse outcomes including preeclampsia and preterm delivery.
Objectives: To assess the extent of vitamin D deficiency/ insufficiency among mothers and their neonates and some factors related to it and identify some adverse outcomes of the deficiency/ insufficiency on neonates (preterm birth and low birth weight).
Subject and Methods: A cross-sectional study was conducted on 88 Iraqi pregnant women and neonates admitted to “Al-Elwiya teaching hospital for maternity” in Baghdad- Al
... Show MoreThe hazardous metabolic effects of treating schizophrenia patients with olanzapine comprise serotonin 2C receptor (5-HT2C) antagonists. Metabolic side effects of antipsychotic drugs, including lipid abnormalities, disturbed glucose metabolism, and weight gain, can have a major impact on treating psychiatric patients. The intent of this study was to investigate whether there is an associated link between the genetic polymorphism at -759C>T in the promoter region of the 5-hydroxytryptamine 2C receptor (HTR2C) gene and the metabolic syndrome driven by olanzapine in schizophrenia patients. A cross-sectional study that involved fifty hospitalized patients with schizophrenia. The patients were split into two groups (metabolic and non-metab
... Show MoreBreast cancer is among the primary causes of death among Iraqi women and is a serious worldwide health concern. ALK or anaplastic lymphoma kinase, is connected to several cancers, including breast cancer.. The goal of this research was to assess the prevalence of anaplastic lymphoma kinase (ALK) with Alkaline phosphatise (ALP) and Lactate dehydrogenase (LDH) together as diagnostic markers. The study comprised 60 patients with metastatic breast cancer and 60 healthy volunteers. The blood levels of the enzymes (ALP), (LDH), and ALK in Iraqi breast cancer patients are compared to those of healthy controls. It was shown that compared to healthy people, patients had breast cancer noticeably greater levels of ALK, ALP, and NDH .These biomarkers m
... Show MoreA reliable and environmental analytical method was developed for the direct determination of tetracycline using flow injection analysis (FIA) and batch procedures with spectrophotometric detection. The developed method is based on the reaction between a chromogenic reagent (vanadium (III) solution) and tetracycline at room temperature and in a neutral medium, resulting in the formation of an intense brown product that shows maximum absorption at 395 nm. The analytical conditions were improved by the application of experimental design. The proposed method was successfully used to analyze samples of commercial medications and verified throughout the concentration ranges of 25–250 and 3–25 µg/mL for both FIA and batch procedures, respecti
... Show More