Preferred Language
Articles
/
injns-67
Effect of Mechanical Surface Treatment on the Tensile Bond Strength of Repaired Acrylic Denture Base Resin Cured by Two Different Techniques
...Show More Authors

Objective: To evaluate and compare the effect of mechanical surface treatment (groove, aluminum oxide particles)
with 45 degree bevel type of joint on tensile bond strength of acrylic specimens repaired by two curing methods
(microwave and water both).
Methodology: Eighty specimens (80) were prepared from pink heat cure acrylic resin. They were divided into two
main groups (40 specimen repaired by microwave energy and 40 specimens repaired by water bath method).Each
group can be divided into four subgroups of ten according to the surface treatment. The control group A was left
intact, group B received no surface treatment, group C and D received surface treatment by (groove, 50 m aluminum
oxide particles). Specimens were tasted by using an instron universal testing machine until fracture occurs.
Result: The results indicate that nurses have adequate knowledge toward general information on infection, infection
control strategy, causes, prevention, sterilization and disinfection, and healthy conditions in operating room
environment. Regarding practices, the results indicated inadequate practices concerning the standard precaution
during wearing operation clothing, patient's preparation, and hand washing practices. While, their practices
concerning tools and equipment preparations were adequate. There is a significant relationship between nurses’
knowledge and practices and their educational level and years of experience.
Recommendation: It can be concluded that mechanical surface treatment prior to denture base repair resulted in a
significant improvement the tensile bond strength of denture base resin.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Addition of Combination of Plasma Treated Polyester and Polyamide Fibers on Surface Roughness and Some Mechanical Properties of Heat Cured Acrylic Resin
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Addition of Combination of Plasma Treated Polyester and Polyamide Fibers on Surface Roughness and Some Mechanical Properties of Heat Cured Acrylic Resin
...Show More Authors

Background: Poly (methyl methacrylate) has several disadvantages (poor mechanical properties) like impact and transverse strength. In order to overcome these disadvantages, several methods were used to strengthen the acrylic resin by using different fibers or fillers. This study was conducted to evaluate the effect of Plasma treatment of the fiber on mechanical properties Poly (methyl methacrylate) denture base material. Materials and methods: Specimens were prepared from poly methyl metha acrylic (PMMA) divided according to present of fiber into 4 groups (first group without fiber as control group, second group with Plasma treated polyester fibers, third group with Plasma treated polyamide fibers and fourth group Plasma treated combination

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength between thermosens as relining material and different denture base materials
...Show More Authors

Background: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strength at the relining-denture base interface is most important for denture durability.The aim of present study was to evaluate the shear bond strength between the thermosens as relining material and different denture base materials that bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dental clinic. Material and method: Sixty samples were prepared and divided into three main groups according to the type of denture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B) referred to the high impact acrylic samples which con

... Show More
View Publication Preview PDF
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of Bond Strength of Acrylic Artificial Teeth with Unreinforced and Nano Silica Reinforced Denture Base Material after Chemical Disinfection
...Show More Authors

Soaking dentures with disinfection solutions is an effective way of keeping dentures in a healthy status; however, immersions in these solutions have a negative effect on the bond strength of denture base and denture teeth. The aim of this study was to evaluate the bond strength between denture acrylic teeth and heat-cured Poly (methyl methacrylate) denture base material (with and without nano silica) after disinfection with different chemical disinfectants for a simulated period of six months. One hundred specimens of maxillary central incisors attached to PMMA were divided into two groups; 50 specimens of PMMA without nano silica and 50 specimens of PMMA reinforced with 5 wt% of nano silica. Specimens of each group were immersed in five i

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of post-pressing times on adaptation of maxillary heat cured acrylic denture base at posterior palatal seal area
...Show More Authors

Background: The purpose of this study was to verify the influence of post- pressing time of acrylic resin (immediate, 6, 12 and 24 hour) on the dimensional accuracy of denture base whish is a critical factor in the retention and stability of the complete denture that may occur during polymerization shrinkage. Materials and Methods: Forty maxillary stone casts were poured in plastic mold (Columbia Dentoform corp. NEW YORK, type III dental stone (Geastone, Zeus Sri Loc.Tamburine Roccastrada, GR, Italy). The stone casts were randomly assigned into 4 groups of 10 specimens each according to the post-pressing times into (immediate, 6, 12 and 24 h.). Heat cure acrylic resin denture base was constructed according to the previously mentioned pressi

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of glass flakes reinforcement on the surface hardness and surface roughness of heat-cured poly (methyl methacrylate) denture base material
...Show More Authors

Background: Heat-cured poly (methyl methacrylate) the principal material for the fabrication of denture base have a relatively poor mechanical properties. The aim of this study was to investigate the effect of glass flakes used as reinforcement on the surface hardness and surface roughness of the heat-processed acrylic resin material. Material and method: Glass flakes (product code: GF002) pretreated with silane coupling agent were added to Triplex® denture base powder using different concentrations. A total of 100 specimens of similar dimensions (65 x 10 x 2.5) mm were prepared, subdivided into 2 main groups of 50 specimens for each of the study tests. Ten specimens for the control group and 40 specimens for each of the experimental gro

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of sodium fluoride on the properties of acrylic resin denture base material subjected to long-term water immersion
...Show More Authors

Background: Fluoridated acrylic resin material can present more stable properties when compared with conventional one.The most widely used fluoride –containing substance added to dental resin materials is sodium fluoride (Naf). This study evaluated the effect of Naf in different concentration to the acrylic resin denture base material and its effect on tensile strength ,modules of elasticity with long –term water immersion (after 4 months immersion in de-ionized water) Materials and methods: Eighty specimens from dumbbells shaped metal pattern for tensile strength test were preparedaccording to ISO 527: 1993 plastic –Determination tensile properties ,in dimensions(60mm, 12mm, 3 ± 0.2mm) length, width and depth respec

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
The Effect of Different Types of Separating Medium On Some Physical Properties of Processing Acrylic Denture-base with Two Investment Materials: A comparative Study
...Show More Authors

Objective(s): In the present study, glycerin is used as a substitute for tin-foil and cold mold seal (Alginate mould seal)
in the process of curing heat and cold-cure acrylic resin denture base against stone and plaster.
Methodology: 60 specimens were prepared from heat-cure acrylic resin and cold-cure acrylic resin denture base. The
study includes 12 groups of specimens depending on the type of processing, investment material and type of
separating medium that are used in curing process. Each group of them contains 5 specimens for each test.
Some of physical properties of the processed acrylic denture base that (water sorption and solubility) have been
compared with those processed using tin-foil and tin-foil substitut

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The Effectiveness of Aluminum Potassium Sulfate Micro-Particles Addition into Soft Denture Lining Material on Tensile strength and Peel bond Strength of Soft Denture Lining Material
...Show More Authors

Naturally available products have been used widely for centuries in handling human disease. The present study aimed to determine the effect of aluminum potassium sulfate addition into the soft liner on tensile strength and peel bond strength. The effect of aluminum potassium sulfate evaluated by two methods, first one include incorporation of KAL (SO4)2 into soft liner monomer in concentration (2%,3% by wt.) while the second method include immersion of soft liner specimens in solution of KAL(SO4)2 in concentration(5%,10% percent) during time periods (0,10 minutes). In conclusions, the results of current study encourage use KAL (SO4)2 within soft liner material

View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Thu Dec 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the effect of sodium fluoride addition on some mechanical properties of heat cure acrylic denture base materials
...Show More Authors

Background: The geriatric patients wearing removable partial dentures are increasing in proportion. At the same time, the root caries prevalence accompanied by gingival recession is increasing. A variety of vehicles can deliver fluoride into the oral cavity, including fluoride mouth-rinse, fluoride dentifrice, topical fluoride, and fluoride-releasing restorative materials, all of which effectively prevent root caries and suppress recurrent caries. This study aimed to evaluate the effect of sodium fluoride addition on some mechanical properties of heat cure acrylic denture base material. Material and method: A total of 90 samples were prepared in this study, then divided into three main groups according to the type of test used (hardness, te

... Show More
View Publication Preview PDF