Objective : The study was carried out to construct an initial assessment documentation tool for nursing
recording system in Coronary Care Unit.
Methodology : A descriptive, purposive sample of (65) nurses was selected from CCU of main
teaching hospitals (Al Karama, Al Kindy, Al Kadimia, Al Yarmmok, Baghdad teaching hospital, Ibn
Al Naffis hospital) and Ibn-Al betar hospital in Baghdad city from the 15th of April 2004 to the 15th of
April 2006.
The instrument was constructed and comprised of two sections: section one included the
nurses' demographic characteristic; section two was the initial assessment documentation tool that
contained (2) parts including: General information form and the initial assessment form. Descriptive and
inferential statistical procedures were used to analyze the data. Reliability of the instrument was
determined for the tool parts and it was (0.85), besides that a panel of experts determined the validity
of the tool.
Results : The findings revealed that the most of the study sample were young male with nursing
institute graduate and the majority of them employed with limited experience ranging between (1-5)
years as general and experience in CCU. In spite of that no one of them got a training course in
documenting their activities.
The present study revealed that, the distribution of nurses' responses to the health pattern indicated that
the (health perception, exchanging, subjective awareness of information, nutrition-metabolic,
elimination, activity and exercise, rest and sleep, cognitive-sensing, and relationship) patterns were the
most appropriate, clear and comprehensive patterns for them.
Most of the international nursing diagnosis items of the tool were clear for nurses except few items.
The results also showed that there was a statistically significant influence between the nurses' responses
to the (11) health patterns with the age variable except in the cognitive - sensing pattern. Moreover, the
level of education patterns significantly influences the entire sample responses.
Banking reforms in many countries have focused on the efficiency enhance of the banking sector, including Iraq, in terms of indicative steps based on recommendations, policies and standards developed by international organizations, foremost of which are Basel III. In this paper, it has tried to highlight the reforms in Basel III and the impact of these reforms on the stability of the banking system in Iraq. As the research derives its importance from the idea that the sound banking system consists of a group of banks capable of employing their assets and obligations efficiently in financial intermediation and enjoying financial solvency. The stability of the banking system is an important factor in achieving the leading role of t
... Show MoreNystatin is the drug of choice for treatment of cutaneous fungal infections with main disadvantage that is the need for multiple applications to achieve complete eradication which may reduce patient compliance. Microparticles offer a solution for such issue as they are one of sustained release preparations that achieve slow release of drug over an extended period of time. The objectives of this study were to fabricate nystatin-loaded chitosan microparticles with the ultimate goal of prolonging drug release and to analyze the influence of polymer concentration on various properties of microparticles. Microparticles were prepared by chemical cross-linking method using glutaraldehyde as cross-linking agent. Five formulas, namely N1C1, N1C2,
... Show MoreA load-shedding controller suitable for small to medium size loads is designed and implemented based on preprogrammed priorities and power consumption for individual loads. The main controller decides if a particular load can be switched ON or not according to the amount of available power generation, load consumption and loads priorities. When themaximum allowed power consumption is reached and the user want to deliver power to additional load, the controller will decide if this particular load should be denied receiving power if its priority is low. Otherwise, it can be granted to receive power if its priority is high and in this case lower priority loads are automatically switched OFF in order not to overload the power generation. The
... Show MoreAbstract
Electric arc furnace applications in industry are related to position system of its pole, up and down of pole. The pole should be set the certain gap. These setting are needed to calibrate. It is done manually. In this research will proposed smart hydraulic to make this pole works as intelligent using proportional directional control valve. The output of this research will develop and improve the working of the electric arc furnace. This research requires study and design of the system to achieve the purpose and representation using Automation Studio software (AS), in addition to mathematically analyzed and where they were building a laboratory device similar to the design and conduct experiments to stud
... Show MoreBackground: Oil refinery workers are continuously exposed to numerous hazardous materials. Petroleum contains the heavy metals as a natural constituent or as additives. These metals induce the production of ROS which associated with an oxidative damage to DNA, proteins, and lipids. This study was conducted to assess the salivary levels of heavy metals, salivary oxidative status, oral immunological activity (salivary sIgA) and assessment of the oral findings among the workers of Al-Daura oil refinery in Baghdad city. Subjects, Materials and Methods: This study was done in Al-Daura oil refinery; samples consist of 60 workers involved in refinery processes (study group) and 20 non-workers (control group). Oral examination and saliva collection
... Show MoreIn this paper, a microcontroller-based electronic circuit have been designed and implemented for dental curing system using 8-bit MCS-51 microcontroller. Also a new control card is designed while considering advantages of microcontroller systems the time of curing was controlled automatically by preset values which were input from a push-button switch. An ignition based on PWM technique was used to reduce the high starting current needed for the halogen lamp. This paper and through the test result will show a good performance of the proposed system.