Compulsion Symptoms among Health Care Providers during the Pandemic of Corona at Baghdad Teaching Hospital
...Show More Authors

Objectives:  The present study aimed to assess the compulsion among health care providers during the pandemic of COVID-19.

Methodology:  a descriptive design was used in the present study.  This study was conducted from October 10th, 2020 through May 20th, 2021.  The study was conducted on a probability (convenient) sample of 248 physicians and nurses who work at Baghdad Teaching hospital in Baghdad city.  The instrument was used in this study is the COVID Stress Scale-Arabic version (CSS).

 Results:  The result of this study showed that 42 % of HCPs had moderate symptoms and 36% of them had mild compulsive symptoms, and only 13% have severe compulsive symptoms according to the score of COVID stress scale.

Conclusions:  78.6 % of the participants had mild to moderate compulsive and 13.7% had sever compulsion.

Recommendations:  All HCPs must get regular and thorough training on how to deal with the pandemic, and there is a need for more researches on how infectious disease epidemics affect the mental health of HCPs.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Bovine Serum Albumin by Aqueous Two-Phase System Using PEG4000/Sodium Citrate and PEG8000/Sodium Phosphate
...Show More Authors

Aqueous Two Phase System (ATPS) or liquid-liquid extraction is used in biotechnology to recover valuable compounds from raw sources. In Aqueous Two-Phase Systems, many factors influence the Partition coefficient, K, (which is the ratio of protein concentration in the top phase to that in the bottom phase) and the Recovery percentage (Rec%). In this research, two systems of ATPS were used: first, polyethylene glycol (PEG) 4000/Sodium citrate (SC), and the second, PEG8000/ Sodium phosphate (SPH), for the extraction of Bovine Serum Albumin (BSA). The behavior of Rec% and K of pure (BSA) in ATPS has been investigated throughout the study by the effects of five parameters: temperature, concentration of polyethylene glycol (P

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Synthesis and Characterization of some Mixed Ligand Complexes Containing (8-hydroxyquinoline) and (2 - picoline) with some Metal Ions
...Show More Authors

Complexes of some metal ions ( Mn(I? ) , Co(??) , Ni(??) ,Cu (??) , Zn(I?) , Cd (??) , and Hg(??) ) with 8-hydroxyquinoline (Oxine) and 2- Picoline (2-pic ) have been synthesized and characterized on the basis of their FT-IR. and Uv-visible spectroscopy ,atomic absorption molar conductivity measurements and magnetic susceptibility ,from the results obtained the following general formula has been given for prepared complexes [M (oxine)2 (2-pic)2]where M = M(??) = Mn , Co , Ni , Cu , Zn , Cd , Hg(oxine)- = ionic ligand 8-hydroxyquinolin (oxinato)(2- pic) = 2- picoline

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat Apr 30 2022
Journal Name
Iraqi Journal Of Science
Impact of PEDOT:PSS Concentration and Heat Treated on Compositional and Some Optical Properties for Graphene Oxide Thin Films
...Show More Authors

     In this study the as-deposited and heat treated at 423K of conductive blende graphene oxide (GO) / poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) thin films was prepared with different PEDOT:PSS concentration (0, 0.25, 0.5, 0.75 and 1.0)wt% on pre-cleaned glass substrate by spin coating technique. The energy dispersive X-ray Analysis (EDX) show the existence of higher amount of carbon and oxygen related to hydroxyl and carbonyl  groups. X-ray diffraction (XRD) analysis of the as-deposited and annealed GO/PEDOT:PSS thin films blend indicated that the film prepared  show broad peak around 8.24 corresponding to the (001) level refers to GO, this peak shifted to the lower 2θ with increasing PEDOT:PSS concentr

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Dec 29 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
B(E2), B(Ml) and 8(E2/ Ml) of Pt (A=198 & (Z=78) Isotope Using IBM-1
...Show More Authors

Interacting boson model version one has been used in the present

theoretical calculations. The energy levels & their transitions for dynamical  symmetry  0(6),  SU(3),  U(5),  ground-state  band,  Beta­ band, Gamma  band, B(E2), Ot, B(Ml), ,u,gt and  6(£2/Ml)have been  calculated  to  deduce  the  limit  of  Pt-198,  Z=78.  The  present results  confirmed  the  nuclear  behavior  of  this  isotope  lay  in  the

transitional region 0(6), SU(3) U(5). The calculations of 021 + & 022+

showed that the shape of this isotope is oblate according to Q21+  and pr

... Show More
View Publication Preview PDF
Publication Date
Mon May 20 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Metformin and Glimepiride Treatment on Some Biochemical Parameters in Diabetic Male Patients with Chronic Renal Failure
...Show More Authors

The present study was included a measurements of fasting serum glucose, total protein, potassium, and calcium levels in the sera of 25 diabetic male patients suffer from chronic renal failure; their ages range were (32-75) and compared them with 25 healthy males as control group. The aim of this study was to study the effects of antidiabetic drugs on some biochemical parameters such as fasting serum glucose, serum total protein, serum potassium and calcium. The current results demonstrated a hyperkalemia in patients and this increasing of potassium is significantly (p = 0.03), but calcium level showed no significant variations ( p>0.05 ), and serum total protein was significantly decreased in patients as compared to t

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Detection of Thrombi in Left Atrial chamber by Transoesophageal Ecchocardiography in patients suffer from Non-rheumatic Atrial Fibrillation
...Show More Authors

Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 19 2021
Journal Name
Annals Of Telecommunications
Challenges and limits of fractal and slot antennas for WLAN, LTE, ISM, and 5G communication: a review paper
...Show More Authors

Abstract Portable communication devices such as WLAN, WiMAX, LTE, ISM, and 5G utilize one or more of the triple bands at (2.32.7 GHz,3.4–3.6GHz,and5–6GHz)andsufferfromtheeffectofmultipathproblemsbecausetheyareusedinurbanregions.To date, no one has performed a review of the antennas used for these types of wireless communications. This study reviewed two types of microstrip antennas (slot and fractal) that have been reported by researchers (as a single element) using a survey that included the evaluation of several important specifications of the antennas in previous research, such as operating bandwidth, gain, efficiency, axial ratio bandwidth (ARBW), and size. The weaknesses in the design of all antennas were carefully identified to de

... Show More
View Publication
Scopus (11)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Feb 25 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Prospective Comparative Study of Fixing Displaced Transverse Patellar Fracture by Tension Band Wiring Versus Cannulated Screws with Wiring
...Show More Authors

BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Materials Chemistry And Physics
Structural, surface electronic bonding, optical, and mechanical features of sputtering deposited CrNiN coatings with Si and Al additives
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2019
Journal Name
Sensors And Actuators B: Chemical
Fabrication and Characterizations of a Novel Etched-tapered Single Mode Optical Fiber Ammonia Sensors Integrating PANI/GNF Nanocomposite
...Show More Authors

View Publication
Scopus (38)
Crossref (45)
Scopus Clarivate Crossref