Objective- the study aim to determine the cardiac patient knowledge about anticoagulant medications using and its relationship with demographic data(age. gender. level of education. occupational). Methodology- A descriptive study(quasi-experimental)design was carried out to determine cardiac patient knowledge consider to using anticoagulant medications . Starting from(1th Jun 2017 to5th October 2018).To achieve the objectives of the study, a non-probability sample (a purposive sample) consisted of random sample comprised of (30) patients were taken anticoagulant medications ..The measurement of patient knowledge were collected through the use of questionnaire which is related to patient knowledge toward using the anticoagulant medications. The questionnaire was interview with cardiac patients who were attended coronary care unit at Al-Sadder Teaching Hospital, and Missan Center of Cardiac Disease and in the Medical Consulting after obtaining agreement from the patients throughout using arabic version of questionnaire. The researcher conducted private meeting with each patient who spends about 25-30 minute to respond to the interview which were developed for the purpose of the study. Instrument validity was determined through content validity, by a panel of experts. Reliability of the instrument was determined through the use of Cronbach Alfa which was (0.85) which are strong acceptable for acute myocardial infarction patients'. Analysis of data was performed through the application of descriptive statistics (frequency, percentage) and inferential statistics (t-test and one way analysis of variance) . Result. when we using mean of score the study showed that low level of knowledge for some items and moderate level of knowledge to other items when ( Low 0.0-0.33) (Moderate 0.34-0.76) (0.67-1.0High).and the result study showed no significant differences between cardiac patient knowledge and demographic data (age, gender ,level of education, occupational) . Recommendation-The researchers recommend the implementation of continuous education programs for cardiac patient about using anticoagulant drugs
Congenital valvular pulmonary stenosis accounts for 5-10% of all congenital heart disease. Balloon pulmonary valvuloplasty is a safe and effective method in reduction of moderate to severe valvular pulmonary stenosis. This retrospective study done in Hawler surgical specialty cardiac center on pediatric patients who had pulmonary valve stenosis (with echocardiographic peak gradient 2:50mmHg) and treated by balloon pulmonary valvuloplasty. A total of 178 cases were involved, 93(52.25%) patient was male and 85 (47.75%) patients was female. 160 patient (89.89%) were treated with single balloon method 18 patient (10.11%) were managed by double balloon method technique. Follow up period of these patients range from 1 year to 10 years (mean of 5.
... Show MoreThe aim of the current research is to identify the level of organizational culture among the headmasters and teachers of intermediate and secondary schools in Arar city. It also aims to identify the effect of job variables, qualifications, educational stage, and years of experience on the level of organizational culture and its domains. The research sample consisted of 62 participants divided into 7 headmasters and 55 teachers. The researcher used the questionnaire of the organizational culture. The researcher used also statistical methods such as mean, standard deviation, t-test, and One way ANOVA. The results revealed that the level of organizational culture and its four domains were high, and there was no effect of the variables (teac
... Show MoreAn Indirect simple sensitive and applicable spectrofluorometric method has been developed for the determination of Cefotaxime Sodium (CEF), ciprofloxacin Hydrochloride (CIP) and Famotidine (FAM) using reaction system bromate-bromide and acriflavine (AF) as fluorescent dye. The method is based on the oxidation of drugs with known excess bromate-bromide mixture in acidic medium and subsequent determination of unreacted oxidant by quenching fluorescence of AF. Fluorescence intensity of residual AF was measured at 528 nm after excitation at 402 nm. The fluorescence-concentration plots were rectilinear over the ranges 0.1-3.0, 0.05-2.6 and 0.1-3.8 µg ml-1 with lower detection limits of 0.013, 0.018 and 0.021 µg ml-1 an
... Show MoreThe aim of this study is to explain methods to be followed for the recovery Alsnav Hor, who represents the northwest portion of the Hammar Marsh in the province of Dhi Qar, after the drought in which that happened in 2008. The study included description of the region before the drought, the description of its natural and human environments, the economic events and activities, then the study included drought throughout the region, the environmental impacts caused by drought, its impact on social reality, economic and healthy for its environment, and then reached to the problems of social and economic in the region, depending on the Field studies and documented in the specialized government departments, information analysis for the
... Show MoreThis research aimed to diagnose the perception based on Telecommunications of Iraq to the importance of activating knowledge management marketing in possession, as well as Indication of impediments to activate the management of marketing knowledge in the researched companies, also aimed to show the extent of the existence of significant differences in perception based on Telecommunications Iraqi importance of activating the management marketing knowledge in possession. To achieve the objectives of this research, the questionnaire was developed and distributed to a sample of telecommunications companies in the city of Sulaimaniya, was selected on the criterion according to the company's life in terms of seniority in the telecommunication
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -
... Show MoreA total of 258 voluntary blood donors (males 101; females 157) in the age range of 18-52 yr among males and 18-55 yr among females were examined for Toxoplasma gondii antibodies (IgG), and (IgM) by immunological technique (Enzyme linked Immunosorbant Assay) during the period from March 2009 to April 2010. This study covered a wide range of factors including immunological, age ,sex , place of residence and symptoms that may have a possible relationship with toxoplasmosis. Results presented in this study showed clearly that 38 (14.7%) of individuals participated in this study having IgG Toxoplasma Ab, among those 10 samples (9.9%) were males and 28 samples (17.8%) were females. Moreover, we found the prevalence of IgM seropositivity in th
... Show MoreA new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg
... Show MoreA rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and
... Show More