Objectives of the study: The study aims to assess satisfy of the coronary artery patients for the care product from
the nurse and physician and to find out the relationship between patient satisfaction with the social and the
clinical characteristics of the patients.
Methodology: A descriptive design study conducted using the evaluation approach for the duration of June 3
rd
2012 to January 31, 2013. Non-probability sample of (60) patients who were visiting or admitted (inpatient or
outpatient) to the teaching hospital in Baquba with the diagnosis of coronary artery disease. A questionnaire have
been built and develop by the researcher based on review of literature and previous research, the form included of
(3) parts: Part I demographic characteristics such as age, gender, education level, marital status, occupation,
monthly income, the second part of clinical data and the third part assessing the satisfaction of patient about the
quality of the physicians care, the quality of nurses care and satisfaction in general.
(12).
Reliability was identified
through the use of (test and retest).The validity was identified by offering experts with competence. The data were
analyzed using descriptive statistics and inferential statistical analysis approach
Results: The results of the study showed that the highest percentage (53.3%) was males under age groups (60-69)
and (36.7%) of the sample were unable to read and write. The study showed that (75.0%) of the sample were
married, (41.7%) of the sample were female and housewife (61.7%) of the respondents live in the city, and (91.7%)
of the sample had one source of income and (61.7%) of the sample had not sufficiently a monthly income. The
results of the study shows that the patients with coronary artery disease were not satisfy with the care provided
by the nurse, the physician and general care in most of the sub domains.
Recommendations: The study recommended there is a need to writing standard education program for the nurse
and the physician in cardiac care unit to improve the care provided to the patient and establishment cardiac center
rehabilitation in all governorate to produce the service to the patient
This study was undertaken to diagnose routine settling problems within a third-party oil and gas companies’ Mono-Ethylene Glycol (MEG) regeneration system. Two primary issues were identified including; a) low particle size (<40 μm) resulting in poor settlement within high viscosity MEG solution and b) exposure to hydrocarbon condensate causing modification of particle surface properties through oil-wetting of the particle surface. Analysis of oil-wetted quartz and iron carbonate (FeCO₃) settlement behavior found a greater tendency to remain suspended in the solution and be removed in the rich MEG effluent stream or to strongly float and accumulate at the liquid-vapor interface in comparison to naturally water-wetted particles. As su
... Show MoreThe goal of this work is to check the presence of PNS (photon number splitting) attack in quantum cryptography system based on BB84 protocol, and to get a maximum secure key length as possible. This was achieved by randomly interleaving decoy states with mean photon numbers of 5.38, 1.588 and 0.48 between the signal states with mean photon numbers of 2.69, 0.794 and 0.24. The average length for a secure key obtained from our system discarding the cases with Eavesdropping was equal to 125 with 20 % decoy states and 82 with 50% decoy states for mean photon number of 0.794 for signal states and 1.588 for decoy states.
In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio
... Show MoreDuring COVID-19, wearing a mask was globally mandated in various workplaces, departments, and offices. New deep learning convolutional neural network (CNN) based classifications were proposed to increase the validation accuracy of face mask detection. This work introduces a face mask model that is able to recognize whether a person is wearing mask or not. The proposed model has two stages to detect and recognize the face mask; at the first stage, the Haar cascade detector is used to detect the face, while at the second stage, the proposed CNN model is used as a classification model that is built from scratch. The experiment was applied on masked faces (MAFA) dataset with images of 160x160 pixels size and RGB color. The model achieve
... Show MoreCase Report.
To present a case of a previous complicated mandibular orthognathic surgery that aimed to setback the mandible in a female cleft lip and palate (CLP) patient, which led to bone necrosis on one side with subsequent severe mandibular deviation and facial asymmetry. We additionally reviewed the previous reports of similar complications, the pathophysiology and the factors that could lead to this dreadful result.
A 27-year-old female patient presented with a severe dentofacial deformity secondary to a complicated bilateral sagittal spli
This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show More