Objective(s): to determine the effectiveness of instruction intervention upon multipara women's practices to
control stress incontinence.
Methodology: A quasi-experimental study was carried out from (2nd) April, 2010 to 15th June, 2010. Nonprobability
(purposive sample) of (60) multiparous women was selected from Baghdad Teaching Hospital and AlElwia
Maternity Teaching Hospital in Baghdad city, the sample was divided into two groups (30) women were
considered as a study group, and another (30) were considered as the control group. An instructional intervention
was applied on the study group, while the intervention was not applied on control group. A questionnaire was
resolve as a tool of data collection to suit the purpose of the study. A pilot study was carried out to test the
reliability and validity of the questionnaire for the period from 10th of March. - 30 March. 2010. Data were
analyzed through the application of descriptive statistical data analysis approach (frequency, percentage, mean of
scores) and inferential statistical data analysis approach (correlation coefficient, and chi- square).
Result: The results of the study revealed that the study group participants had benefited from the implementation
of instructional intervention and dramatic change had occurred in their practices to control stress urinary
incontinence. The study concluded that the majority of mothers had adequately met their needs control stress
urinary incontinence-pelvic floor and perineum muscles exercise, and lifestyle change.
Recommendation: The study recommended that the instructional intervention can be presented to all multipara
pregnant mothers who are attending to the primary health care centers; moreover, an instructional intervention
might be implemented in the hospital for multipara women to increase their knowledge about stress urinary
incontinence. The study also recommended that the nurse must take the role for teaching multiparous women the
principles of control SUI while they perform such procedure for them during postpartum period.
The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed
... Show MoreThis study presents an adaptive control scheme based on synergetic control theory for suppressing the vibration of building structures due to earthquake. The control key for the proposed controller is based on a magneto-rheological (MR) damper, which supports the building. According to Lyapunov-based stability analysis, an adaptive synergetic control (ASC) strategy was established under variation of the stiffness and viscosity coefficients in the vibrated building. The control and adaptive laws of the ASC were developed to ensure the stability of the controlled structure. The proposed controller addresses the suppression problem of a single-degree-of-freedom (SDOF) building model, and an earthquake control scenario was conducted and simulat
... Show MoreThe heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed
... Show MoreThe evolution in the field of Artificial Intelligent (AI) with its training algorithms make AI very important in different aspect of the life. The prediction problem of behavior of dynamical control system is one of the most important issue that the AI can be employed to solve it. In this paper, a Convolutional Multi-Spike Neural Network (CMSNN) is proposed as smart system to predict the response of nonlinear dynamical systems. The proposed structure mixed the advantages of Convolutional Neural Network (CNN) with Multi -Spike Neural Network (MSNN) to generate the smart structure. The CMSNN has the capability of training weights based on a proposed training algorithm. The simulation results demonstrated that the proposed
... Show MoreIn this paper, our purpose is to study the classical continuous optimal control (CCOC) for quaternary nonlinear parabolic boundary value problems (QNLPBVPs). The existence and uniqueness theorem (EUTh) for the quaternary state vector solution (QSVS) of the weak form (WF) for the QNLPBVPs with a given quaternary classical continuous control vector (QCCCV) is stated and proved via the Galerkin Method (GM) and the first compactness theorem under suitable assumptions(ASSUMS). Furthermore, the continuity operator for the existence theorem of a QCCCV dominated by the QNLPBVPs is stated and proved under suitable conditions.
Electronic Health Record (EHR) systems are used as an efficient and effective method of exchanging patients’ health information with doctors and other key stakeholders in the health sector to obtain improved patient treatment decisions and diagnoses. As a result, questions regarding the security of sensitive user data are highlighted. To encourage people to move their sensitive health records to cloud networks, a secure authentication and access control mechanism that protects users’ data should be established. Furthermore, authentication and access control schemes are essential in the protection of health data, as numerous responsibilities exist to ensure security and privacy in a network. So, the main goal of our s
... Show MoreBackground: Coronavirus pandemic (COVID-19) has enormously affected various healthcare services including the one of community pharmacy. The ramifications of these effects on Iraqi community pharmacies and the measures they have taken to tackle the spread of COVID-19 is yet to be explored. In this cross sectional survey, infection control measures by community pharmacies in Sulaimani city/Iraq has been investigated.
Methods: Community pharmacists were randomly allocated to participate in a cross-sectional survey via visiting their pharmacies and filling up the questionnaire form.
Results and discussion:
... Show More