Objectives: To identify quality of life (QOL) in Myocardial Infarction (MI) patients, and to find out the
relationship between QOL in MI patients and demographic characteristics.
Methodology: A descriptive colTelation study which utilized an assessment approach. The study was carried out
from March 2007 through November 2007 in order to assess the quality of life for patients with myocardial
infarction. A purposive "non-probability" sample of (75) patients with myocardial infarction who were attending
to Baquba General Hospita`l through their visits to that hospital. A questionnaire was adapted and developed
from the World Health Organization Quality of Life Scale (1998). The questionnaire was designed and
consisted of (2) parts, the fust part includes demographic characteristics of Myocardial Infarction patients,
clinical characteristics of these patients and medical sheet information. The second one consists of six domains
of quality of life. Reliability was determined by using test and retest technique through a Pilot study. Data were
analyzed through descriptive data analysis approach (Frequency and percentage) and the inferential data analysis
approach (Pearson con.elation coefficient and chi-square).
Results: The results of the study indicated that (53.3%) of the sample was male and (41.7%), age between (61-
70) years, (68.0%) was married and more than two third of sample were unable to read and write, (44%) of the
sample was housewife (do not work). The findings of the study present that the demographic characteristics of
MI patients such as gender, level of education had a significant relationship with their quality of life. The
socioeconomjc characteristics of patients such as marital status hnd no significant relationship with the patients'
quality of life. The finding also shows disease had moderate, low and no effect on quality of life through the
relative sufficiency from the spiritual domain (RS=83.8), the independence (RS=76.9), psychological domain
(RS=76.7), physical domain (RS=74.6), social domain a`S=69.9), and environment domain (RS=62.3).
Recommendations: The study recommended that an educational program for MI patients to help them have a
better QOL and advice them how to cope with their problems for a good QOL.
This paper considers a new Double Integral transform called Double Sumudu-Elzaki transform DSET. The combining of the DSET with a semi-analytical method, namely the variational iteration method DSETVIM, to arrive numerical solution of nonlinear PDEs of Fractional Order derivatives. The proposed dual method property decreases the number of calculations required, so combining these two methods leads to calculating the solution's speed. The suggested technique is tested on four problems. The results demonstrated that solving these types of equations using the DSETVIM was more advantageous and efficient
This study investigates the potential of biogas recovery from used engine oil (UEO) by co-digestion with animals’ manure, including cow dung (CD), poultry manure (PM), and cattle manure (CM). The experimental work was carried out in anaerobic biodigesters at mesophilic conditions (37°C). Two groups of biodigesters were prepared. Each group consisted of 4 digesters. UEO was the main component in the first group of biodigesters with and without inoculum, whereby a mix of UEO and petroleum refinery oily sludge (ROS) was the component in the second group of biodigesters. The results revealed that for UEO-based biodigesters, maximum biogas production was 0.98, 1.23, 1.93, and 0 ml/g VS from UEO±CD, UEO±CM, UEO±PM, and U
... Show MoreThe paper presents a highly accurate power flow solution, reducing the possibility of ending at local minima, by using Real-Coded Genetic Algorithm (RCGA) with system reduction and restoration. The proposed method (RCGA) is modified to reduce the total computing time by reducing the system in size to that of the generator buses, which, for any realistic system, will be smaller in number, and the load buses are eliminated. Then solving the power flow problem for the generator buses only by real-coded GA to calculate the voltage phase angles, whereas the voltage magnitudes are specified resulted in reduced computation time for the solution. Then the system is restored by calculating the voltages of the load buses in terms
... Show MoreThis paper considers a new Double Integral transform called Double Sumudu-Elzaki transform DSET. The combining of the DSET with a semi-analytical method, namely the variational iteration method DSETVIM, to arrive numerical solution of nonlinear PDEs of Fractional Order derivatives. The proposed dual method property decreases the number of calculations required, so combining these two methods leads to calculating the solution's speed. The suggested technique is tested on four problems. The results demonstrated that solving these types of equations using the DSETVIM was more advantageous and efficient
The absorption spectrum for three types of metal ions in different concentrations has been studying experimentally and theoretically. The examination model is by Gaius model in order to find the best fitting curve and the equation controlled with this behavior. The three metal ions are (Copper chloride Cu+2, Iron chloride Fe+3, and Cobalt chloride Co+2) with different concentrations (10-4, 10-5, 10-6, 10-7) gm/m3. The spectroscopic study included UV-visible and fluorescence spectrum for all different concentrations sample. The results refer to several peaks that appear from the absorption spectrum in the high concentration of all metal ions solution.
... Show MoreA single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1
... Show More