Objective: Evaluation the national standards for exposure to chemical materials and dusts in The State
Company for Drugs Industry in Samarra.
Methodology: A descriptive evaluation design is employed through the present study from 25th May 2011
to 30th November 2011 in order to evaluate the national standards for exposure chemical materials and dusts
in The State Company for Drugs Industry in Samarra. A purposive (non-probability) sample is selected for the
study which includes (110) workers from the State Company for Drugs Industry in Samarra. Data were
gathered through the workers` interviewed according to the nature of work that they perform. The evaluation
questionnaire comprised of three parts which include the workers` demographic characteristic and other two
part which concern the national standards for exposure to chemical materials and dusts in workplace.
Reliability and validity of this tool is determined through application of a pilot study and panel of experts. Data
were analyzed through the application of descriptive statistical (frequencies and percentages) and inferential
statistical (mean of score).
Results: The findings of the study present that the national standards for exposure chemical materials and
standards for exposure to dusts that are applicable in the workplace, can be adopted as national
standards. So, there is no significant impact of occupational hazards that may affect workers and work
environment as a result of applicable of this standards.
Recommendations: The study recommends that increase awareness, training and health education
programs should be provided for all workers regularly and periodically in order to help them comply
with standards for exposure chemical materials and standards for exposure to dusts in order to avoid
hazards that affecting their health and work environment.
The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed
... Show MoreMost Internet of Vehicles (IoV) applications are delay-sensitive and require resources for data storage and tasks processing, which is very difficult to afford by vehicles. Such tasks are often offloaded to more powerful entities, like cloud and fog servers. Fog computing is decentralized infrastructure located between data source and cloud, supplies several benefits that make it a non-frivolous extension of the cloud. The high volume data which is generated by vehicles’ sensors and also the limited computation capabilities of vehicles have imposed several challenges on VANETs systems. Therefore, VANETs is integrated with fog computing to form a paradigm namely Vehicular Fog Computing (VFC) which provide low-latency services to mo