Objective: the aim of this study is to invest age and determine the effect of using (2) packing
technique (conventional and new tension technique) on hardness of (2) types of heat cure acrylic
resin which are (Ivoclar and Qual dental type).
Methodology : this study was intended the using of two types of heat cure acrylic (IVoclar and
Qual dental type) which are used in construction of complete denture which packed in two different
packing technique (conventional and new tension technique) and accomplished by using a total of
(40) specimens in diameter of ( 2mm thickness, 2 cm length and 1 cm width) . This specimens were
sectioned and subdivide into (4) group each (10) specimens for one group , then signed as (A, Al B , B
1) according to the method of technique and type of acrylic that used . The hardness of the specimens
were measured by shore hardness test in technology university, Baghdad.
Results: this study revealed that the type of acrylic which packed by new tension technic had less
effect by hardness in compared with conventional packing technic, the result also showed that the
type of acrylic resin have a little effect on hardness of the two types, and also it show highly mean
value of hardness was indicate in Qual dental type in conventional technique, while the least mean
value of hardness showed in Ivoclar type in new tension technique.
Recommendations : this study has been conducted as a preliminary for future studies to give a sit
of about the effect of hardness on other types of commercial heat acrylic resin that used in
construction of prosthodontics restoration and dented prosthesis, it necessary to evaluate the
hardness of any material used in construction of denture bases , it is suggested to under take a farther
studies about using advance technique and better apparatus and device in packing the acrylic
material and measured the value of hardness and its effect on this material.
Crude-colicin was extracted from g.coli isolated from urinary tract
infection patients. Toxicity of various concentrations of crudt: colicin
on the viability of immune cells [phagocytic ceUs(M0,PMN) and lymphocytes] was studied. Results indicated that toxicity ciTect of crude colicin is dependent on concentration. Low concentrations (I0,
25, 50 mg/ml) didn't have toxic effects, but when there was an increase in the consternation of this extract, the viability of the immune cell s began to decrease.
Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i
... Show MoreEpoxy (EP) – Silica (SiO2) composites are well known composites used in microelectronic industry . So it is important to study their dielectric behavior under different conditions such as
the presence carbon black (UV absorber) and immersion in the water for 30 days .
Dielectric properties were calculated over the frequency range 102 – 106 Hz for epoxy composites with different weight % of micrometer 1.5μm SiO2 particles (60%, 65% and 70wt%) modified with 0.5wt% silane coupling agent to improve adhesion between EP and SiO2 phases .
Carbides or nitrides thin films present materials with good mechanical properties for industrial applications as they can be coatings at low temperatures serve temperature sensitive surfaces. In this work the effect of the C percentage on the mechanical properties represented by the Young modulus (E) of combinatorial magnetron sputtered TiCx (34%x˂65%) has been studied. The structure of the produced films is TiC independent on the C concentration. The mechanical properties are increased with increasing the C concentration up to 50%, and then decreasing with further C % increasing. These results can be explained by considering the resultant residual stresses.
This study explains the effect of non-thermal (cold) plasma on wound of diabetic rats by (FE-DBD) system, 3cm probe diameter is used. The output power was ranged from (12-20) W. The effect of non-thermal plasma on wounds of a diabetic was observed with different exposure durations (20,30) sec., the plasma exposure duration decreases the sugar level in blood and the diameter of the wound. These results indicate the cold plasma can be used to enhance the insulin level (i.e., blood sugar) and wounds treatment.
In this paper, a novel coronavirus (COVID-19) model is proposed and investigated. In fact, the pandemic spread through a close contact between infected people and other people but sometimes the infected people could show two cases; the first is symptomatic and the other is asymptomatic (carrier) as the source of the risk. The outbreak of Covid-19 virus is described by a mathematical model dividing the population into four classes. The first class represents the susceptible people who are unaware of the disease. The second class refers to the susceptible people who are aware of the epidemic by media coverage. The third class is the carrier individuals (asymptomatic) and the fourth class represents the infected ind
... Show MoreThis research includes study of the effect of two kinds of Anthocyanin extracted , from extracted orange fruit ( Anthocyanin Evolvulus ,Methiola Violet ) on two types of pathological bacteria E.coli , staphylococcus aureus. The result shows that two kinds of extraction have nearly similar effect , and there is Inhibition zone of no growth between 10-12mm ,and the extraction (1) that has concentration of 10-3 mol./L is more effective..
Porous silicon (PS) layers were formed on n-type silicon (Si) wafers using Photo- electrochemical Etching technique (PEC) was used to produce porous silicon for n-type with orientation of (111). The effects of current density were investigated at: (10, 20, 30, 40, and50) mA/cm2 with etching time: 10min. X-ray diffraction studies showed distinct variations between the fresh silicon surface and the synthesized porous silicon. The maximum crystal size of Porous Silicon is (33.9nm) and minimum is (2.6nm) The Atomic force microscopy (AFM) analysis and Field Emission Scanning Electron Microscope (FESEM) were used to study the morphology of porous silicon layer. AFM results showed that root mean square (RMS) of roughness and the grain size of p
... Show MoreIn this study, Laser Shock Peening (LSP) effect on the polymeric composite materials has been investigated experimentally. Polymeric composite materials are widely used because they are easy to fabricate and have many attractive features. Unsaturated polyester resin as a matrix was selected and Aluminum powder with micro particles as a reinforcement material was used with different volume fraction (2.5%, 5% and 7.5%). Hand lay-up process was used for preparation the composites. Fatigue test with constant amplitude with stress ratio (R =-1) was carried out before and after LSP process with two levels of energy (1Joule and 2Joule). The result showed an increase in the endurance strength of 25.448% at 7.5% volume fraction when peened is 1J
... Show MoreFluoxetine (FX) is an antidepressant drug administered only orally in humans. Despite the wide use of FX, until now, there is only limited literature concerning the pharmacokinetics (PK) of FX and the effect of food on its PK. Thus, the objective of this investigation was to study the PK of FX in Arabic healthy male adult volunteers under fasting and fed conditions. In the fasting study, FX 20 mg capsules (Prozac®, Eli Lilly, Canada) were administered to 41 volunteers after overnight fasting of 12 hours, followed by blood sampling from each volunteer immediately before dosing (zero time) and then at 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 24, 36, 48, 60, 72, 96, 120, and eventually at 144 hours after FX dosing. The fed study was conduct
... Show More