Objective(s): To measure serum C-reactive protein (CRP) titer as a predictive diagnosis of acute hepatitis C virus (HCV)
infection.
Methodology: Two hundred and ten patients with acute HCV infection and 234 apparently healthy individuals as
control group were enrolled in this study in Baghdad medical city (Teaching Laboratories). The patents include
74(35.2%) females and 136 (64.8%) males with mean age (27±16.5) years. The control group includes 114 (48.7%)
females and 120 (51.3%) males with mean age (26±5.8) years. Blood samples were collected from out patients from
Alfadul in Baghdad city. Sera were separated and stored at 20 0
C. The diagnosis of acute HCV infection was based on
detection of HC Ag and anti- HCV IgM and standard liver function tests. Determination of CRP titer was assessed by
semi-quantitative tube agglutination test. All data were statistically analyzed.
Results: Based on 95% percentile, the baseline CRP titer in healthy individuals was 1:8 (16mg/l) and for patients 1:512
(1024mg/l). There was a statistically significant increase in the mean CRP titer in patients with acute HCV infection
compared to healthy individuals (P< 0.001) .The validly of CRP titer 1: 64 as a cut –off value to predict HCV infection
provide a sensitivity and specificity of 100 % and 96% respectively. Furthermore, there was a significant correlation
between CRP titer and liver function test values.
Recommendation:
Therefore, in further studies, we recommends the evaluation of C- reactive protein titer in patients with acute
hepatitis B Virus infection and patients with non–infectious diseases such as cardiovascular disease, diabetes mellitus
and hyperlipidemia infection, and compare between them.
The existing investigation explains the consequence of irradiation of violet laser on the structure properties of MawsoniteCu6Fe2SnS8 [CFTS] thin films. The film was equipped by the utilization of semi-computerized spray pyrolysis technique (SCSPT), it is the first time that this technique is used in the preparation and irradiation using a laser. when the received films were processed by continuous red laser (700 nm) with power (>1000mW) for different laser irradiation time using different number of times a laser scan (0, 6, 9, 12, 15 and 18 times) with total irradiation time (0,30,45,60,75,90 min) respectively at room temperature.. The XRD diffraction gave polycrysta
... Show MoreIn this article four samples of HgBa2Ca2Cu2.4Ag0.6O8+δ were prepared and irradiated with different doses of gamma radiation 6, 8 and 10 Mrad. The effects of gamma irradiation on structure of HgBa2Ca2Cu2.4Ag0.6O8+δ samples were characterized using X-ray diffraction. It was concluded that there effect on structure by gamma irradiation. Scherrer, crystallization, and Williamson equations were applied based on the X-ray diffraction diagram and for all gamma doses, to calculate crystal size, strain, and degree of crystallinity. I
... Show More