Preferred Language
Articles
/
injns-105
Early detection of first degree relatives to type-II diabetes mellitus
...Show More Authors

Objective(s): The study aims to assess the early detection of early detection of first degree relatives to type-II
diabetes mellitus throughout the diagnostic tests of Glycated Hemoglobin A1C. (HgbA1C), Oral Glucose Tolerance
Test (OGTT) and to find out the relationship between demographic data and early detection of first degree
relatives to type-II diabetes mellitus.
Methodology: A purposive "non-probability" sample of (200) subjects first degree relatives to type-II diabetes
mellitus was selected from National Center for Diabetes Mellitus/Al-Mustansria University and Specialist Center
for Diabetes Mellitus and Endocrine Diseases/Al-kindy. These related persons have presented the age of (40-70)
years old. A questionnaire was constructed for the purpose of the study, it is composed of (3) major parts, and
overall items, which are included in the questionnaire are (76) items. Reliability and validity of the questionnaire
were determined through a pilot study which is carried out during the period of August, 1
st
, 2008 to February, 30th
2009. The study instrument and structured interview technique were used as means of data collection. The data
were analyzed through the application of the descriptive statistical data analysis approach (Frequency and
Percentage) and the inferential statistical data analysis approach Chi-square, Pearson correlation coefficient.
Results: The results of the study confirmed that the mean of age is (55.7) year, and the majority of the sample are
male, first degree relatives with diabetes mellitus type-II are within positive bio-social aspect and laboratory
screening had an effect on the incidence of diabetes mellitus type-II for first degree relatives to type-II diabetes
mellitus.
Recommendations: The study recommends that the number of diabetes centers should be increased in Baghdad
and Governorates, promote of HbA1c test from general hospitals laboratories, guide notebook about the
predisposing factors of diabetes mellitus in his family, periodic screening for pre-diabetes and diabetes in high risk,
asymptomatic, undiagnosed adults within the health care setting, prevention program to prevent and control on
the predisposing risk factors for nondependent diabetes mellitus type-II and complication

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Detection of Epicatechin in Camellia sinensis Leaves by Thin Layer Chromatography and High Performance Liquid Chromatography Techniques
...Show More Authors

    The current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method) involved using three different solvents which are  absolute ethanol, 50% aqueous ethanol and water  for both extraction methods using room temperature and direct heat respectively. Crude extracts of two tea samples that obtained from two methods were fractionated by using two solvents with different polarity (chloroform and

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
Scopus (23)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry & Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
View Publication
Scopus (23)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Analytical And Bioanalytical Chemistry Research
Mutual Derivatization in the Determination of Dapsone and Thymol Using Cloud Point Extraction Followed by Spectrophotometric Detection
...Show More Authors

A procedure for the mutual derivatization and determination of thymol and Dapsone was developed and validated in this study. Dapsone was used as the derivatizing agent for the determination of thymol, and thymol was used as the derivatizing agent for the determination of Dapsone. An optimization study was performed for the derivatization reaction; i.e., the diazonium coupling reaction. Linear regression calibration plots for thymol and Dapsone in the direct reaction were constructed at 460 nm, within the concentration range of 0.3-7 μg ml-1 for thymol and 0.3-4 μg ml-1 for Dapsone, with limits of detection 0.086 and 0.053 μg ml-1, respectively. Corresponding plots for the cloud point extraction of thymol and Dapsone were constructed

... Show More
Scopus (4)
Scopus
Publication Date
Tue Apr 19 2022
Journal Name
Chemistryselect
A Continuous Flow Injection/Indirect Photometric Method for the Detection of Fosetyl Aluminum in Commercial Pesticide Formulations
...Show More Authors
Abstract<p>Because of their Physico‐chemical characteristics and its composition, the development of new specific analytical methodologies to determine some highly polar pesticides are required. The reported methods demand long analysis time, expensive instruments and prior extraction of pesticide for detection. The current work presents a new flow injection analysis method combined with indirect photometric detection for the determination of Fosetyl‐Aluminum (Fosetyl‐Al) in commercial formulations, with rapid and highly accurate determination involving only construction of manifold system combined with photometric detector without need some of the pre‐treatments to the sample before the analysis such a</p> ... Show More
View Publication
Scopus (8)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon May 18 2026
Journal Name
Scientific Reports
Fluorescein spectrofluorometric quenching detection of chloride and iodide using eight-Blue-LEDs excitation and dual solar cells
...Show More Authors
Abstract<p>This study presents a novel, custom‑built fluorescence detector for the precise determination of chloride and iodide ions based on their quenching effect on fluorescein. The detection system incorporates eight blue LEDs irradiation sources arranged at 0–90° angles relative to twin solar cell detectors connected. Two fluorescence quenching strategies were developed. The injected‑mixture mode (IMFQ) exhibited linear ranges of 0.00–1.00 mM for Cl⁻ and 0.00–1.25 mM for I⁻, with detection limits of 20 µM and 10 µmol L⁻¹, respectively. The continuous‑flow mode (CFFQ) demonstrated superior sensitivity with a dispersion factor of 1.33, wider linear ranges (0.1–6.0 m</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Mon Feb 01 2016
Journal Name
Swarm And Evolutionary Computation
Improving the performance of evolutionary multi-objective co-clustering models for community detection in complex social networks
...Show More Authors

Scopus (34)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Thu Oct 23 2025
Journal Name
Baghdad Science Journal
Continuous Flow Injection-Turbidimetric Analysis for Determination of Cobalt (II) Ion in Alloys Using a Microcell with Irradiation Sources at 0–180° Using a Single Solar Cell as a Detector
...Show More Authors

A cost-effective and efficient detector was created to conduct thorough turbidimetric measurements by reaction of Co (II) ion with calcium ferro cyanide to form bright green particulate, using the method of continuous flow injection analysis, the use of NAG-5SX1-1D-SSP Analyzer in determining cobalt (II) ion in a test for the validity of the new design. The NAG-5SX1-1D-SSP Analyzer is composed of five irradiation sources of white snow leds having the diameter of 10 mm with one solar cell of 55 mm length, 13.5 mm width. Using a selector switch to select the optimum voltage to be used which was 2.7 VDC. Under conditions of optimization, cobalt (II) ion was determined at 0.005–20 mmol. L–1(n = 23) while linearity dynamic range 0.005–7 mm

... Show More
View Publication
Scopus (4)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Oct 23 2023
Journal Name
Journal Of Optics
Single mode optical fiber sensor based on surface plasmon resonance for the detection of the oil aging for the electrical transformers
...Show More Authors

This work presents a novel technique for the detection of oil aging in electrical transformers using a single mode optical fiber sensor based on surface plasmon resonance (SPR). The aging of insulating oil is a critical issue in the maintenance and performance of electrical transformers, as it can lead to reduce insulation properties, increase risk of electrical breakdown, and decrease operational lifespan. Many parameters are calculated in this study in order to examine the efficiency of this sensor like sensitivity (S), signal to noise ratio (SNR), resolution (refractive index unit) and figure of merit (FOM) and the values are for figure of merit is 11.05, the signal to noise ratio is 20.3, the sensitivity is 6.63, and the resolution is 3

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Oct 15 2026
Journal Name
Journal Of Baghdad College Of Dentistry
A Clinical Method for Prediction of Alveolar Bone Mineral Density in the Area between the Second Premolar and First Molar in Iraqi Adults with Class I Occlusion
...Show More Authors

Background: Orthodontic mini-implants are increasingly used in orthodontics and the bone density is a very important factor in stabilization and success of mini-implant. The aim of this study was to observe the relationship among maximum bite force (MBF); body mass index (BMI); face width, height and type; and bone density in an attempt to predict bone density from these variables to eliminate the need for CT scan which have a highly hazard on patient. Materials and Methods: Computed tomographic (CT) images were obtained for 70 patients (24 males and 46 females) with age range 18-30 years. The maxillary and mandibular buccal cortical and cancellous bone densities were measured between 2nd premolar and 1st molar at two levels from the alveol

... Show More
View Publication Preview PDF