Four major factories (Petroleum Refineries Company, Detergents Plant, Thermal Power Plant, and Gaseous Power Plant) are located to the north of Baiji City. They release pollutants in form of gases, liquids and solids; they find their way to the surrounding environment. To assess the environmental pollution of the area, 18 samples of surface soil distributed around the industrial establishments were collected and analyzed to determine the concentration of polycyclic aromatic hydrocarbons (PAH) components which are often targets in the environmental checking. Identification and quantification of the 16 PAHs components was accomplished using High Performance Liquid Chromatography (HPLC) had a model Shimadzu LC-10 AVP. The total concentrations of 16 PAHs were ranged from (94.9) to (416.3) μg/kg with an average value of (217.5) μg/kg. The most abundant PAHs was Fluorene followed by Acenaphthylene, Naphthalene, Chrysene, Phenanthrene, Benzo(b)fluora-nthene, Fluoranthene, Benzo(a)anthracene, Benzo(a)pyrene, Benzo(g,h,i)perylene, Dibenzo(a,h)anthracene, Indeno(1,2,3-cd) pyrene, Pyrene, Acenaphthene, Anthracene, and Benzo(k)fluoranthene.
Seven possible carcinogenic PAHs (Σ7c-PAHs) accounted 38.9 % to the total PAHs. The petroleum combustion and biomass combustion were the main sources of PAHs in the surface soil. The mean values of cancer risk levels for children via ingestion, dermal contact, and inhalation were (6.02*10-7), (7.51*10-7) and (5.91*10-12) respectively, suggesting no potential health hazards, while these for adults were (1.78*10-6), (3.16*10-6) and (1.40*10-10) respectively, implying potential health risks via ingestion and dermal contact, but not via inhalation exposure. The total value of ILCRing+drm+inh for children and adults via three exposure pathways were (2.43*10-5) and (8.90*10-5) respectively, indicating potential health risks.
The corrosion inhibition of low carbon steel in1N HCl solution in the presence of peach juice at temperature (30,40,50,and 60)°C at concentration ( 5, 10, 20, 30, 40and 50 cm3/L)were studied using weight loss and polarization techniques. Results show that the inhibition efficiency was increased with the increase of inhibitor concentration and increased with the increase of temperature up to 50ºC ,above 50ºC (i.e. at 60 ºC) the values of efficiency decreases. Activation parameters of the corrosion process such as activation energies, Ea, activation enthalpies, ΔH, and activation entropies, ΔS, were calculated. The adsorption of inhibitor follows Langmuir isotherm. Maximum inhibition efficiency obtained was a bout 91% at 50ºC in the
... Show MoreThe Urban Residential has developed and changed in different periods of time with successive and gradual shifts, as it cast a shadow over the characterization of modern urbanism in Iraq. The semi-total absence of the governing legislation of urbanization as well as the weakness of the State's role of supervisory in addition to neglecting urban heritage contributed in offering a strange environment in relation to its traditional identity. That was increased by the pressure of the using urban environment as a result of the increasing of population as well as the growth of people’s needs. The research aims to provide an objective view for a mechanism of the application of urban legislation to monitor the implementation o
... Show MoreNosocomial infections (NIs) are hospital-acquired associated infections, and also contracted due to the infections or toxins that exist in some location, like hospital. Therefore in our study, 4 Lactic acid bacteria (LAB) isolates were obtained from dairy product (Lactobacillus brevis, L. acidophilus, Lactococcus raffinolactis and Lactococcus lactis) and were tested for Bacteriocin production to select Lactococcus lactis among them. Cell free supernatant (CFS), Lipid and partial purification of protein La. Lactis had high inhibitory effect against test pathogens (E. coli, Bacillus cereus, Staphylococcus aureus and Streptococcus). 30 isolates that diagnosed by Vitec, were isol
... Show MoreHeat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.
The Al Mishraq site has been the subject of many scientific studies for the period before and
after the fire in 2003. Five visits to the site were conducted twice in 2003 for general fact-finding, twice
in 2004, and once in 2005 for detailed sampling and monitoring. Desk-based research and laboratory analysis of soil and water samples results indicate that surface water and groundwater pollution from Al Mishraq site was significant at the time of its operation. The primary pollution source was the superheated water injection process, while the principal receptor is the River Tigris. Now that the plant is idle, this source is absent. Following the June 2003 sulphur fire, initial investigations indicate that short damage to
vegeta
The charge transfer at C23H17F8N8O2PRu, C44H30BF4N5O4Ru, C56H52CL5N5OOsP2 and C76H88F80N24O11P10Ru4 nitrosyl complexes are investigation and studies theoretically using the quantum consideration. Charge transfer behavior largely rely to the electric properties of nitrosyl complexes system whose depending on the main important parameters for the transmission rate constant such that: orientation transition energy, overlapping coupling coefficient, driving force energy, height barrier and Temperature T (K). Data results have been evaluated using a MATLAB program. Results show that rate of charge transfer increases due to increases the orientation transition energy.
Objective: Diarrhea is a symptom of a variety of conditions may attack the child. It considered one of
mam causes of mortality rates especially in low socio- economic level countries. The child can be
easily got dehydration and pass from loss of too much body fluid and due to the Common thoueht of
increasing the incidence of diarrhea during summer season, this study is done to find out the relation
between the high incidences rate of diarrhea and weather variation
Methodology: This survey conducted in AL- Markazi Child's Teaching Hospital for the year 2005 the
data were gathered from hospital records for the period (January - December) and age groups
taxonomy used by hospital applied. Descriptive statistical analysis
It is an analytical study carried out at university of Basra using a sample included the dean ,assistants and managers of scientific dept. in the university for about(63)managers .The study aimed at discovering a model of crises management in the university.The researcher adopted the descriptive survey methodology.To achieve the objective of the study ,a questionnaire of (41)statements was developed covering five main variables like ,signal detection, prevention and preparedness, response, recovery and learning .The validity of the questionnaire was done by a group of referees .Its stability was determined by Cronbach,s Alfa .The questionnair,s stability coefficient was(0.
... Show MoreHeat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically in the present work. Solar chimney was tested by selecting different positions of absorber namely: at the back side, front side, and at the middle of the air gap. CFD analysis based on finite volume method is used to predict the thermal performance, and air flow in two dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation. Results show that a solar chimney with absorber at the middle of the air gap gives better ventilation performance. A comparison between the numerical and previous experimental results shows fair agreement.