Preferred Language
Articles
/
ijs-9416
Organic Geochemistry and Stable Carbon Isotopes of Oil Seepages in the Abu-Jir Fault Zone at Al-Anbar Governorate, Iraq
...Show More Authors

Oil seep samples along Abu-Jir Fault Zone were studied to determine their chemical characterization and origin. They are dominated by the normal alkanes, more complex mixture of branched and cyclic hydrocarbons. Organofacies coupled with the stable carbon isotopes have been integrated to infer the oil seep origin. Oil seeps contain H2S gas, which derives as a catabolic by product of sulfate-reducing bacteria from gypsum of the Fatha Formation during the early diagenetic under anoxic conditions which is demonstrated by values of C29/H that are greater than 1. The oil seeps are characterized by δ13C values vary from -29.0 to -27.96‰ and from -28.34 to -27.88‰ in the saturated and aromatic compounds, respectively; consequently, they have low values of the canonical variable ranged from -3.47 to -0.17 reflecting a marine non-waxy oil generated from planktonic kerogen of type-II that has been partially mixed with the terrestrial origin. The values of the tricyclic terpanes (C22/C21 and C31R/H) that are higher than 0.5 and 0.25 respectively support the marine source rocks. The Triassic age was suggested for the oil age in the dependence of the occurrence of the aromatic dinosteranes which marked dinoflagellates were participated in the oil derivation.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Brazilian Dental Science
Wound healing effect of a one-week Aloe Vera mouthwash: a pilot study
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Al-nahrain Journal Of Science
Adsorption of P-Aminodiphenylamine with Iodine Charge Transfer Complex on Surface Arundo Plant
...Show More Authors

charge transfer complex formed by interaction between the p- aminodiphenylamine (PADPA) as electron donor with iodine as electron acceptor in ethanol at 250C as evidenced by color change and absorption. The spectrum obtained from complex PADPA – Iodine shows absorptions bands at 586 nm. All the variables which affected on the stability of complex were studies such as temperature, pH, time and concentration of acceptor. The linearity of the method was observed within a concentration rang (10–165) mg.L-1 and with a correlation coefficient (0.9996), while the molar absorbitivity and sandell sensitivity were (4643.32) L.mol-1.cm-1 and (0.0943) μg.cm-2, respectively. The adsorption of complex PADPA–I2 was studied using adsorbent surfaces

... Show More
Crossref
Publication Date
Sun Oct 30 2022
Journal Name
Iraqi Journal Of Science
Some Applications of Quasi-Subordination for Bi-Univalent Functions Using Jackson’s Convolution Operator
...Show More Authors

     In this paper, subclasses of  the function class  ∑  of analytic and bi-univalent functions associated with operator  L_q^(k,  λ)  are introduced and defined in the open unit disk △ by applying quasi-subordination. We obtain some results about the corresponding bound estimations of the coefficients  a_(2 )  and a_(3 ).

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Mar 01 2018
Journal Name
Materials Today Communications
Improved mechanical properties of sol-gel derived ITO thin films via Ag doping
...Show More Authors

View Publication
Scopus (18)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
10.31272/jeasd.23.5.9
EVALUATION OF HOT MIX ASPHALT CONTAINING RECLAIMED ASPHALT PAVEMENT TO RESIST MOISTURE DAMAGE
...Show More Authors

Due to increasing cost of asphalt binder, significant economic savings can be realized by using the amount from reclaimed asphalt pavement (RAP) in the production of new hot mix asphalt (HMA). Moreover, this is an environmentally friendly option as it reduces the demand for virgin materials. It has to be remarked that in Iraq RAP is not used in the production of HMA and this valuable material is mostly degraded for use in lower value applications. Four mixtures were designed, which contains three different percent RAP, it is (0%, 5%, 15%) with asphalt grade (40-50) and (25%) with asphalt grade (60-70), it has been changed the grade of asphalt when adding RAP (25%) to compensate for the aged binder in the RAP when adding to mixture. All type

... Show More
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Wed Feb 01 2023
Journal Name
International Journal Of Electrical And Computer Engineering
Classification of COVID-19 from CT chest images using Convolutional Wavelet Neural Network
...Show More Authors

<p>Analyzing X-rays and computed tomography-scan (CT scan) images using a convolutional neural network (CNN) method is a very interesting subject, especially after coronavirus disease 2019 (COVID-19) pandemic. In this paper, a study is made on 423 patients’ CT scan images from Al-Kadhimiya (Madenat Al Emammain Al Kadhmain) hospital in Baghdad, Iraq, to diagnose if they have COVID or not using CNN. The total data being tested has 15000 CT-scan images chosen in a specific way to give a correct diagnosis. The activation function used in this research is the wavelet function, which differs from CNN activation functions. The convolutional wavelet neural network (CWNN) model proposed in this paper is compared with regular convol

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 18 2021
Journal Name
Materials Science And Engineering
Properties of engineered cementitious composite concrete (bendable concrete) produced using Portland limestone cement
...Show More Authors

Bendable concrete, also known as Engineered Cementitious Composite (ECC) is a type of ultra-ductile cementitious composites reinforced with fibres to control the width of cracks. It has the ability to enhance concrete flexibility by withstanding strains of 3% and higher. The properties of bendable concrete mixes (compressive strength, flexural strength, and drying shrinkage) are here assessed after the incorporation of supplementary cementitious materials, silica fume, polymer fibres, and the use of ordinary Portland cement (O.P.C) and Portland limestone cement (IL). Mixes with Portland limestone cement show lower drying shrinkage and lower compressive and flexural strength than mixes with ordinary Portland cement, due to the ratio o

... Show More
Publication Date
Wed Jan 20 2021
Journal Name
Earth And Environmental Science
Time Dependent Behavior of Engineered Cementitious Composite Concrete Produced from Portland Limestone Cement
...Show More Authors

Conventional concretes are nearly unbendable, and just 0.1 percent of strain potential makes them incredibly brittle and stiff. This absence of bendability is a significant cause of strain failure and has been a guiding force in the production of an elegant substance, bendable concrete, also known as engineered cement composites, abbreviated as ECC. This type of concrete is capable of displaying dramatically increased flexibility. ECC is reinforced with micromechanical polymer fibers. ECC usually uses a 2 percent volume of small, disconnected fibers. Thus, bendable concrete deforms but without breaking any further than conventional concrete. This research aims to involve this type of concrete, bendable concrete, that will give solut

... Show More
Publication Date
Tue Nov 15 2022
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
A-mechanical properties of engineered cementitious composite concrete produced from Portland limestone cement
...Show More Authors

Conventional concretes are almost unbending, and even a small amount of strain potential leaves them brittle. This lack of bendability is a major source of strain loss, and it has been the main goal behind the development of bendable concrete, often known with engineered ce ment composites, or ECC. This form of concrete has a lot more flexibility than regular concrete. Micromechanical polymer fibers are used to strengthen ECC. In most cases, ECC uses a 2% amount of thin, separated fibers. As a result, bendable concrete deforms but unlike traditional concrete, it does not crack. This study aims to include this kind of concrete, bendable concrete, which can be used to solve concrete problems. Karasta (CK) and Tasluja (CT) Portland Lime

... Show More
Publication Date
Sun Mar 31 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Behavior of Clay Masonry Prism under Vertical Load Using Detailed Micro Modeling Approach
...Show More Authors

The aim of this research is to assess the validity of Detailed Micro-Modeling (DMM) as a numerical model for masonry analysis. To achieve this aim, a set of load-displacement curves obtained based on both numerical simulation and experimental results of clay masonry prisms loaded by a vertical load. The finite element method was implemented in DMM for analysis of the experimental clay masonry prism. The finite element software ABAQUS with implicit solver was used to model and analyze the clay masonry prism subjected to a vertical load. The load-displacement relationship of numerical model was found in good agreement with those drawn from experimental results. Evidence shows that load-displacement curvefound from the finite element m

... Show More
Crossref (1)
Crossref