The study aims to identify the acceptability of drinking water for human consumption depend on Iraqi specification and WHO standards. Samples collected monthly for each station from March to December2014. The samples collected from six stations distributed in Baghdad City, the first two stations located in al-Kadmyai area , the 3rd and 4th located in AL- Doora while the last two stations located in Al-Amryai area. The study measured physical, chemical and bacteriological factors. The measured parameters were ranged each for pH 6.63-7, turbidity 0.4-1.3NTU,TDS394.2-960mg/l,total hardness 259.1-578while Ca and Mg were 43-134,20.1-72 mg /l respectively. Other chemical parameters like chloride ranged from 56.8-184 mg/l and heavy metals ranged from 0-0.01,0-0.053,0.038mg/l for Pb+2,Cu+ and Fe+ respectively. The bacteriological examination included a total count for aerobic bacteria which is ranging from 0-10000 cell/ml, Coliform, and fecal coliform were ranged 0-3000, 0-300 cell/ml respectively. The results compared with standard limits and found some parameters exceeded the acceptable limits.
This study included the compromised the containing Hardness and some ions of treated water in central Karbala drinking water treatment station with Iraqi and international drinking water criteria. Also, this study was attempted to focus on probable pollution sources. The Hardness and other waters salts Sulphates (SO4), Chloride ion (Cl-), Calcium ion (Ca+2), and Magnesium ion (Mg+2) tests criteria were determined on water samples taken from Al-Hussainia River water source, treated drinking water during October-November 2013 to August - September 2014.Study results revealed an increasing in Total hardness (TH), sulfate, chloride, calcium, in winter (December- January) 2014. In addition, the results showed a decrease in above mentioned cri
... Show MoreThe importance of research lies in the school administration and that the school is the main cell of the educational system and its ultimate goal, and therefore modern education requires the presence of sophisticated leaders represented in educational administration at various levels. Administrative leaderships and the two researchers' belief that the institution’s ability and success or failure depend on a special type of leader who is highly effective and efficient, directing workers ’behavior towards creativity and achievement in order to achieve the goals of the institution in serving the educational bodies, increasing the effectiveness of leadership and developing the creative behavior of secondary school principals in
... Show MoreIn this research we study one of the pollutants(Gelbstoff ) such as Humic and Fulvic Acids in tap waters by using the technique of Raman, Flora to some regions of Baghdad , the results appear that the tap waters were pollutants which know yellow substance or Gelbstoff instant of suspending waters, which appear through the scattering of the incident light to same the wave length of Raman ,also calculate Raman shift which was 3640 cm-1 and force constant to band (O – H ) was 743 N/m, where the peak of Raman was at the wave length 441 nm after used the excitation wave length 380 nm . The results were in an agreement with lectures [8][9][10].
Waters of some wells at Almuqdadea region Diyala province, east of Iraq have been
compared with wells at Alfalluja region, Alanbar province west of Iraq. Five wells were
selected randomly at each of the two regions to measure several factors represented by
temperature (C), P
H
, Electric Conductivity (EC), Sodium (Na),Calcium (Ca), Magnesium
(Mg),Total Hardness (TH), Carbonate (Co3),Chloride (Cl), Nitrite (NO2), Nitrate (NO3)
Phosphate (PO4) Sulfate (So4), in addition to the heavy metals such as Chromium (Cr),
Cadmium (Cd) Lead (Pb) & Iron (Fe). The mean concentration of the above factors in water
of wells at the above regions had been measured during the period from April to September
(2010).
The water quality index is the most common mathematical way of monitoring water characteristics due to the reasons for the water parameters to identify the type of water and the validity of its use, whether for drinking, agricultural, or industrial purposes. The water arithmetic indicator method was used to evaluate the drinking water of the Al-Muthana project, where the design capacity was (40000) m3/day, and it consists of traditional units used to treat raw water. Based on the water parameters (Turb, TDS, TH, SO4, NO2, NO3, Cl, Mg, and Ca), the evaluation results were that the quality of drinking water is within the second category of the requirements of the WHO (86.658%) and the first category of the standard has not been met du
... Show MoreThe water quality index is the most common mathematical way of monitoring water characteristics due to the reasons for the water parameters to identify the type of water and the validity of its use, whether for drinking, agricultural, or industrial purposes. The water arithmetic indicator method was used to evaluate the drinking water of the Al-Muthana project, where the design capacity was (40000) m3/day, and it consists of traditional units used to treat raw water. Based on the water parameters (Turb, TDS, TH, SO4, NO2, NO3, Cl, Mg, and Ca), the evaluation results were that the quality of drinking water is within the second category of the requirements of the WHO (86.658%) and the first category of the standard has not
... Show MoreSoil is considered one of the main factors of subsidence phenomena which
became continually happen in Baghdad (Ghazalia, Ameria, and Hay al-Amyl)
causing bad effects as shortage of drinking water, traffic jam and formation
swamps.
This thesis depends on soil study to a depth 15 meters, due to its
importance in subsidence. This done through specifying its chemical physical
properties.
Soil within Iraq climate, in case of water stopping for any reason it contract
and shrink away especially when it exposed to high pressure these factors
finally caused subsidence. In case of leakage underground water or that of
damaged water pipes this will contribute to chemical reactions which damage soil
structure and incr
For cleaner air and unpolluted continue assessment study air pollution the city of
Baghdad by measuring the concentrations of air pollutants, which included TSP, Pb, where
the adoption of three stations (Andalus Square, Jadiriya, Allawi) are distributed in the city of
Baghdad in order to compare the concentrations of these pollutants with previous studies.
Study pointed out that the city's air contaminant, especially in minutes outstanding after
deducting the amount of atmospheric dust thick mechanism city this year where the highest
concentration of minutes outstanding (9895) micrograms / m 3 at the station Alawi and lower
concentration of 157 micrograms / m 3 at the station Alawi and this was higher than the
det
Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
Water is an essential aspect of life and important in evolution. Recently the potable water quality topic has received much attention. The study aims to determine drinking water quality in Al-Najaf City by collecting samples throughout Al-Najaf city and comparing the results with the Iraqi guidelines (IQS 417) and World Health Organization (WHO) guidelines, as well as to calculate the WQI. Samples were tested in the laboratory between December 2021 and June 2022. The results showed that multiple parameters exceeded the allowable limits during both testing periods; during winter months, the results of TDS and turbidity exceeded the upper limits in multiple locations. Total hardness values also
... Show More