The research work present a sensitive, accurate and fast developed for the determination of oxonium ion (HCl, H2SO4 , HClO4 and tartaric acid). It relies on the formation free iodine molecule from the I--IO3--H3O+ reaction which react with fluorescein sodium salt solution causing to quench the fluorescence light (continuous fluorescence) when irradiated by laser source at 405nm. Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used. The flow rate of 1.3 and 1.5 mL/min was used, 35μL sample volume no.1 and sample volume no.2 , linear dynamic range extend from 0.05-7, 0.05-7, 0.1-10 and 0.1-10 mMol.l-1 with correlation coefficient of 0.9933, 0.9964, 0.9984 and 0.9973 for HCl, H2SO4 , HClO4 and tartaric acid respectively. Using t-test it was shown that there was no significant difference between two methods (adopted and classical method) for both acid at 95% confidence level.
Geodesy is concerned with the relative positioning of points and the gravity field of the earth. For this task, a well-defined coordinate system is needed on which measurements are normally tied to a set of reference points called a geodetic datum (geoid or ellipsoid). The Global Positioning System GPS gives accurately the three-dimensional position of a point (latitude, longitude, and ellipsoidal height) and can measure under all weather conditions. The coordinates of the GPS reference to the World Geodetic System1984 (WGS 84), a global ellipsoid having its origin as the mass center of the earth, and height, referenced to the surface of the ellipsoid . In this research , using RTK-DGPS technique Data collection for study local and level
... Show MoreNeutron differential-elastic and inelastic scattering cross-sections of Yttrium-89 isotope were calculated at energies 8,10,12,14, and 17 MeV, at angles distributed between 20o and 180o in the center of mass frame. The obtained results data were interpreted using a spherical optical potential model and Eikonal approximation, to examine the effect of the first-order Eikonal correction on the effective potential. The real and imaginary parts of optical potential were calculated. It was found that the nominal imaginary potential increase monotonically while the effective imaginary one has a pronounced minimum around r = 6fm and then increases. The analysis of the relative energy of the projectile and reaction
... Show MoreThis study was aimed to develop an optimized Dy determination method using differential pulse voltammetry (DPV). The Plackett-Burman (PB) experimental design was used to select significant factors that affect the electrical current response, which were further optimized using the response surface method-central composite design (RSM-CCD). The type of electrolyte solution and amplitude modulation were found as two most significant factors, among the nine factors tested, which enhance the current response based on PB design. Further optimization using RSM-CCD shows that the optimum values for the tw
... Show MoreA newly developed analytical method characterized by its speed and sensitivity for the determination of mefenamic acid (MFA) in pure and pharmaceutical preparation is established via turbidimetric measurement (0-180o) by Ayah 6SX1-ST-2D Solar cell CFI Analyser . The method was based on the reaction of
phosphomolybdic acid with mefenamic acid in aqueous medium to form blue color precipitate as an ion-pair complex . Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o . The chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.3-7 or 0.3-10 mMol.L-1, with correlation coefficient r = 0.9907 or 0.9556 respectively
Grass carp at a weight of 34.68 + 2 g were gradually exposed to four saline concentrations: tap water (0.1), 3, 6, 9, and 12 gm/litter, and the first concentration represented a control treatment. Fish were fed on a diet with a protein content of 30% for ten weeks. Results of the growth experiment showed that the feed conversion rate was 2.46, 3.58, 4.84, 6.77, and -8.56 in the first to fifth treatments, respectively, and the rate feed conversion efficiency was 40.65, 27. 93, 20.66, 14.77 and 11.68 %, while the protein intake was 22.38, 20.44, 18.86, 17.47 and 16.56 g in salt concentrations of 0.1, 3, 6, 9 and 12 g/L, respectively. In another experiment to study the effect of salt acc
Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm
... Show MoreThis study investigated the applicability of iron oxide (Fe2O3) nanoparticles for the removal of cadmium metal from sewage water by using batch scale experiments. The iron oxide nanoparticles of 27.7nm were synthesized using a biological method and characterized by Atomic Force Microscope (AFM). The Box-Wilson design was used to conduct experiments with three parameters such as pH (2-6), time of adsorption (6-120min) and adsorbent dosage (5-25mg/L). The best conditions occurred at pH: 5.5; contact time: 95.8 min; and iron oxide nanoparticle dosage: 20.77 mg/L for maximum cadmium removal of (96.9%).
Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the