Hydrogeological investigation and water budget calculation of Koi Sanjaq basin is carried out. This investigation includes the determination of the aquifer types extending through the study area and flow direction as well as aquifer hydraulic properties values. Three main unconfined aquifer types were distinguished , they are (Pilaspi), , (Bihassan-Muqdadiya and Fatha –Injana) Formations , where the flow map of the unconfined aquifers shows that the flow direction is from northern and northeastern parts towards the south and southeastern parts i.e. .Lesser Zab River. Analysis of pumping test data of 9 selected wells from unconfined aquifers show that T values range from 1.51m2/day to 64.4 m2/day revealing the great variations in the aquifer lithology, extend of fissures and fractures as well as the saturated thickness of the water bearing zones. Water balance calculations are achieved using meteorological data of three meteorological stations: Erbil, Koysanjaq and Dukan , where Mehtas model is used to calculate the water surplus values which found to be equal 203.9 mm/ year. Soil Conservation Service method (SCS) and curve number methods are adopted to determine the amount of runoff where the soil type is the most critical factor. According to the infiltration rates measured by the authors, all of the study area soil is of A group, therefore the calculated value of runoff is 128.72mm/year. Overall calculations of the water balance components shows that the groundwater recharge is 75.18 mm/year, representing 10.84 % of the total rainfall for the study area.
This study was carried out to study effect of magnetic water ( M0 and M) and different concentrations of coconut extract in Fragaria x ananassa (Duch) C.V Festival. The results showed significant differences in the plants treated with magnetic water ( 0.12 Tesla) and different concentrations of coconut extract C1 (0%), C2 (2.5%), C3 (5%), C4 (7.5%) and C5 (10%) in vegetative parameters as in leaf area and chlorophyll in treatment M0C3 was (53.72 Dcm2, 50.00), respectively, highest leaf number and plant dry weight in MC4 (12.77,14.22 gm), respectively. Results recorded significant differences in fruit parameters such as weight in MC1 (18.97 gm). The maximum fruit number was in MC3 (110), the greatest fruit size was in MC4 (15.78 cm3) and the
... Show MoreA total of 551 water samples (drinking and raw water) were collected In this study, Aeromonas.hydrophila, were detected by biochemical tests and PCR (16s rRNA gene). The results of identification showed that A.hydrophila had recovery rate 63 isolates (49.21%). The results revealed that all A.hydrophila isolates were PCR positive or the 16S rRNA gene and the results of sequencing showed that two isolates of A.hydrophila(local isolates) had percentage similarities 100% with A. hydrophila ATCC 7966 in GenBank database .All strains had a minimal Inhibitory Concentration(MIC) distribution pattern for lead cetate rranged (900-1200 μg/ml), and mercury chloride ranged (40-80 μg /ml).
A new bio-electrochemical system was proposed for simultaneous removal of organic matters and salinity from actual domestic wastewater and synthetically prepared saline water, respectively. The performance of a three-chambered microbial osmotic fuel cell (MOFC) provided with forward osmosis (FO) membrane and cation exchange membrane (CEM) was evaluated with respect to the chemical oxygen demand (COD) removal from wastewater, electricity generation, and desalination of saline water. The MOFC wasinoculated with activated sludge and fueled with actual domestic wastewater. Results revealed that maximum removal efficiency of COD from wastewater, TDS removal efficiency from saline water, power density, and current density were
... Show MoreThe primary objective of the present research is to diagnose the most mportant imensions of quality of work life in a sample of individuals working in the Northern Gas Filling Company in Nynawa. The study sample consisted of 140 employees of the Northern Region Filling Company in even ,Through a questionnaire prepared for this purpose. The study concluded that there are five main factors that are considered to be measure of the quality of working life and are based on their importance: Empowerment, organizational health, internal work environment, motivation, development and training of workers. The study recommended that the organization should payattentio
... Show MoreOne of the most important of satellite image is studying the surface water
according of its distribution and depth. In this work, three images have been taken
for Baghdad and surrounding for year (1991, 1999 and 2014) and by using of envi
program has been used. Different classes have been evaluated for Al-Habania and
Al-Razaza River according to its depth and water reflectance. In the present work
four types of water depth (very shallow, shallow, moderate, and deep area) have
been detected.
Imam Ibn Abi Shaybah counted in his book classified twenty-five and a hundred recent and impact claimed that Abu Hanifa has violated the provisions required by apparent, and these conversations and effects including with regard to worship and transactions, including with regard to personal status, including with regard to borders and felonies, and collected by Sheikh Muhammad Zahid Al-Kothari in his book funny jokes in talking about the responses of Ibn Abu Shaybah on Abu Hanifa, and these issues we will study in our research.
ABSTRACT
The purpose of the research is to identify the role of drinking water quality in achieving customer satisfaction in one of the formations of the Ministry of Construction, Housing and Public Municipalities (Diwaniyah Water Directorate), as they are important service organizations that have a fundamental role in serving the community. Faced many administrative challenges, as a result of the continuous and accelerating environmental changes, environmental pollution and immaturity of social awareness and social responsibility, as these contributed to and affected the quality of drinking water, Therefore, it is necessary to know the role of quality, specifically "drinking water and its effect o
... Show MoreThe sun which is all energy sources, in today's society, hot water is used for various purposes starting from household to power production. People are adopting various ways to accomplish these goals, such as firewood heat and electrical power, so solar energy is an alternative to the dwindling resources of fossil fuels. Conversion of solar radiation into heat is one of the simplest and most direct applications of this energy, it can be used to heat water systems. A widely used flat-plate solar collector. In this study we have come to heat water using solar energy. This research presents the design and experimental analysis for using Spiral Flow Solar Water Heater (SFSWH) to enhance the thermal efficiency of a flat plate solar collector.
... Show MoreThe vacancy of natural resources is undoubtedly limited by time. The sustainable development principle recommends modern technology for its protection and renewal. This project conducted analyses on two underground water sources in the north of Algeria (Mechroha Province). Besides, the use of the hardness factor and the adoption of the titration method, which is the determining the concentration of an unknown solution using a known solution concentration, have permitted the characterization of the examples taken and to verify their conformity to the standard required, the results found showed HT=6.66 French degrees (oF) ) for Ain Guilloume water spring in comparison to Ain Messai water spring H