This study compares the effects of plasma jet and plasma-activated water on teeth root canals contaminated with Escherichia coli bacteria. A plasma jet system was developed for biological purposes that operate at atmospheric pressure. The plasma jet works with argon gas and is generated by a power supply, which supplies a sinusoidal alternating voltage of 12 kV of 20 kHz frequency. The system was optically diagnosed, as it was found that the peaks of the nitrogen spectrum were obtained at the wavelength (300- 450) nm with the appearance of hydroxide peaks at 380 nm. Extracted teeth with one root canal were used, which were contaminated with bacteria and divided into two groups to be treated with a plasma jet and plasma-activated water. The first group was treated with a plasma jet at a gas flow of 2.5 L/min with a change of treatment time from 0.5 to 3 minutes. The number of killed bacteria colonies increased when the exposure time increased (2.7×108 CFU per mL - 0), and the total killing of bacteria was obtained at 3 minutes treatment time. While the second group was treated with plasma-activated water; the water used to kill the bacteria was treated with plasma for one hour at a gas flow rate of 1 L/min. The measured concentrations of (NO2, NO3, and H2O2) of this water were (10, 100 and 200) ppm. The teeth were treated with plasma-activated water for different times that ranged between (5- 35) minutes. Different bacterial killing rates were obtained at these times, and the total bacterial killing rate was obtained for 35 minutes of treatment time. The obtained results found that the response of bacteria to treatment with plasma jet is better than treatment with plasma-activated water.
In this manuscript has investigated the synthesis of plasma-polymerized pyrrole (C4H5N) nano-particles prepared by the proposed atmospheric pressure nonequilibrium plasma jet through the parametric studies, particularly gas flow rate (0.5, 1 and 1.5 L/min). The plasma jet which used operates with alternating voltage 7.5kv and frequency 28kHz. The plasma-flow characteristics were investigated based on optical emission spectroscopy (OES). UV-Vis spectroscopy was used to characterize the oxidization state for polypyrrole. The major absorption appears around 464.1, 449.7 and 435.3 nm at the three flow rate of argon gas. The chemical composition and structural properties of the
... Show MoreThe research aims to develop and build a plasma jet system operating under atmospheric pressure.for biological purposes. The advanced plasma system consists of a power supply and a plasma torch. The source of the development of the system is a previous laboratory system that was developed by changing the voltage and frequency of the power supply, as the power provider equips the system with a voltage in the form of a sine wave whose value is fixed at about (7.5kV) peak to peak and its frequency is about (28 kHz). The plasma torch consists of a teflon tube with of width of (10 m ) located at (10mm) from the end of the tube. The current waveform and voltage wave were measured using a current and voltage sensor and an oscilloscop
... Show MoreIn this study, gold nanoparticles (AuNPs) were synthesized using a plasma jet system at different exposure times. Using ultraviolet, visible spectra, X-ray diffraction, the nanoparticles were characterized (XRD). A Plasmon surface resonance concentrated at 530, 540, and 533 nm for the prepared AuNPs. The pattern of XRD showed that the extreme peaks of the film reflect crystalline existence. The face-centered cubic structure of the gold nanoparticles was prepared for all samples, with an average crystallite size of 25-40 nm. The effect of AuNPs in vivo on liver function levels was measured. For all doses, we notice an increase in the ranks of liver function in the blood during the period of dosing, and it begins to decrease when the dosi
... Show MoreNano- particles (Ag NPs) are synthesized by using plasma Jet argon gas. The prepared Ag NPs are characterized by Atomic Absorption Spectroscopy (AAS) The measure was performed for different time exposuring 15,30,45 and 60 sec. The results shows the low concentration of nano-silver time expose (15 sec) and very) and high concentration at 60 sec. The UV-VIS spectrometer for nano-silver different time exsposuring to plasma, shows the Surface Plasmon Resonance (SPR) appeared around 419 nm, and the energy gab is 4.1 eV for the 15 second exposure and 1.6eV for 60 second exposure. The Scanning Probe Microscope (SPM) is used to identify the characterization of silver nanoparticles, the average diameter of nano-silver for 15 second exp
... Show MoreBackground: Plasma-activated water (PAW) is considered one of the emerging strategies that has been highlighted recently in the food industry for microbial decontamination and mycotoxin detoxification, due to its unique provisional characteristics. Aim: The effectiveness of PAW for aflatoxin B1 (AFB1), ochratoxin A (OTA), and fumonisin B1 (FB1) detoxification in naturally contaminated poultry feeds with its impacts on the feed quality were inspected. Methods: PAW-30 and PAW-60 were utilized for feed treatment for six time durations (5, 10, 15, 20, 40 and 60 min) each. The alterations in the physicochemical properties of PAW after different time durations of plasma inducement and treatment with and without feed samples were monit
... Show MorePMMA/TiO2 homogeneous thin films were deposited by using plasma jet system under normal atmospheric pressure and room temperature. PMMA/TiO2 nanocomposite thin film synthesized by plasma polymerization. Titanium oxide was mixed with Methyl Methacrylate Monomer (MMA) with specific weight ratios (1, 3 and 5 grams of TiO2 per 100 ml of MMA). Optical properties of PMMA/TiO2 nanocomposite thin films were characterized by UV-Visible absorption spectra using a double beam UV-Vis-NIR Spectrophotometer. The thin films surface morphological analysis is carried out by employing SEM. The structure analysis are achieved by X-ray diffraction. UV-Visible absorption spectra shows that the increasing the concentration of titanium oxide added to the polym
... Show MoreThe development in the field of medical physics has led to the use of devices that
are manufactured under normal conditions to make tremendous progress in the
world of development in medical treatment by using these devices with modern
techniques by reducing the use of antibiotics and relying on these tools and devices
that link between physics and modern therapeutic medicine. In this research, a nonthermal
plasma system for argon gas operated at normal atmospheric pressure was
designed, this system was applied on Pseudomonas Aeruginosa bacteria isolated
from burn patients from Yarmouk Teaching Hospital. These bacteria were exposed
to this system, the results showed that these bacteria were killed at time (5 min)
Urinary tract infection is a bacterial infection that often affects the bladder and thus the urinary system. E. coli is one of the leading uropathogenic bacteria that cause urinary tract infections. Uropathogenic E. coli is highly effective and successful in causing urinary tract infections through biofilm formation and urothelial cell invasion mechanisms. Other organisms that cause urinary tract infections include members of the Enterobacteriaceae family, streptococci and staphylococci species and perch. In addition, K.penumoniae is another important gram-negative bacterium that causes urinary tract infections. With the PCR technique, unseen bacterial species can be detected using standard clinical microbiology methods. In this study, the
... Show MoreSurface wettability plays a significant role in determining the function of the wound dressing. They should have hydrophobic surfaces for the adsorption of bacteria and a hydrophilic surface necessary to improve cell attachment for most anchorage-dependent cell types. Furthermore, the Hydrophobicity / Hydrophilicity of the surface can be used to direct cellular processes such as cell initial correlation, adhesion, and migration during wound healing, as a result such surface can change its surface wettability which increases the dressing's usefulness.
In this research, nanomembres were prepared from polycaprolactone and chitosan solution (with different amounts of CS (0.05, 0.1, 0.2, and 0.4) % (w/w)) by the electrospinning m