The spatial assessment criteria system for hybridizing renewable energy sources, such as hybrid solar-wind farms, is critical in selecting ideal installation sites that maximize benefits, reduce costs, protect the environment, and serve the community. However, a systematic approach to designing indicator systems is rarely used in relevant site selection studies. Therefore, the current paper attempts to present an inclusive framework based on content validity to create an effective criteria system for siting wind-solar plants. To this end, the criteria considered in the related literature are captured, and the top 10 frequent indicators are identified. The Delphi technique is used to subject commonly used factors to expert judgments. Other factors are considered according to expert recommendations. In this context, the assessment tool was a combination of questionnaires and interviews with experts from scientific backgrounds that reflect the measurement target. The item-level content validity index (I-CVI) is applied along with the modified Kappa statistic (k*) to analyze expert ratings and suggestions. The results demonstrate the superiority of 9 and 4 commonly used factors and the suggested factors, respectively. The 13 criteria have achieved high agreement among experts at I-CVIs ≥ 0.78 and k*s > 0.76. The conclusion can be drawn that the modified Kappa statistic used in this analysis has a more significant effect on eliminating irrelevant factors. The current methodology and consequences might pave the way for making informed decisions to locate wind and solar farms.
The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature
... Show MoreA fluorescence microscopy considered as a powerful imaging tool in biology and medicine. In addition to useful signal obtained from fluorescence microscopy, there are some defects in its images such as random variation in brightness, noise that caused by photon detection and some background pixels in the acquired fluorescence microscopic images appear wrongly auto-fluorescence property. All these practical limitations have a negative impact on the correct vision and analysis of the fluorescent microscope users. Our research enters the field of automation of image processing and image analysis using image processing techniques and applying this processing and analysis on one of the very important experiments in biology science. This research
... Show MoreThe evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient
In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi
... Show MoreFabrication and investigation of the properties of CdSe/ZnS core/shell for the luminescent solar concentrates (LSC) application is presented. An increase of the efficiency of a silicon solar cell was obtained by applying the LSC. The increase was a result of the optical properties of the semiconductor nanoparticles CdSe/ZnS core/shell that were deposited over the top surface of the silicon solar cell facing the illumination source (Halogen lamp). The gravity force was invested for the film deposition process.The optical properties of these nanoparticles were studied. The absorption spectra for the CdSe/ZnS core-shell were 270-600nm, i.e., located within the spectral response area of the examined solar cell. The energy gap values for CdSe
... Show MoreABSTRACT: BACKGROUND: Left ventricular hypertrophy is a significant risk factor for cardiovascular complications such as ischemic heart disease, heart failure, sudden death, atrial fibrillation, and stroke. A proper non-expensive tool is required for detection of this pathology. Different electrocardiographic (ECG) criteria were investigated; however, the results were conflicting regarding the accuracy of these criteria. OBJECTIVE: To assess the accuracy of three electrocardiographic criteria in diagnosis of left ventricular hypertrophy in adult patients with hypertension using echocardiography as a reference test. PATIENTS AND METHODS: This is a hospital-based cross sectional observational study which included 340 adult patients with a his
... Show MoreThe CIGS/CdS p-n junction thin films were fabricated and deposited at room temperature with rate of deposition 5, and 6 nm secG1 , on ITO glass substrates with 1mm thickness by thermal evaporation technique at high vacuum pressure 2×10G5 mbar, with area of 1 cm2 and Aluminum electrode as back contact. The thickness of absorber layer (CIGS) was 1 µm while the thickness of the window layer CdS film was 300 nm. The X-ray Diffraction results have shown that all thin films were polycrystalline with orientation of 112 and 211 for CIGS thin films and 111 for CdS films. The direct energy gaps for CIGS and CdS thin films were 1.85 and 2.4 eV, respectively. Atomic Force Microscopy measurement proves that both films CIGS and CdS films have nanostru
... Show More